7 matches found
CVE-2022-1098
Delta Electronics DIAEnergie (all versions prior to 1.8.02.004) are vulnerable to a DLL hijacking condition. When combined with the Incorrect Default Permissions vulnerability of 4.2.2 above, this makes it possible for an attacker to escalate privileges
CVE-2022-26839
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) is vulnerable to an incorrect default permission in the DIAEnergie application, which may allow an attacker to plant new files (such as DLLs) or replace existing executable files.
CVE-2022-0988
Delta Electronics DIAEnergie (Version 1.7.5 and prior) is vulnerable to cleartext transmission as the web application runs by default on HTTP. This could allow an attacker to remotely read transmitted information between the client and product.
CVE-2021-23228
DIAEnergie Version 1.7.5 and prior is vulnerable to a reflected cross-site scripting attack through error pages that are returned by “.NET Request.QueryString”.
CVE-2024-4549
A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. When processing an 'ICS Restart!' message, CEBC.exe restarts the system.
CVE-2021-44471
DIAEnergie Version 1.7.5 and prior is vulnerable to stored cross-site scripting when an unauthenticated user injects arbitrary code into the parameter “name” of the script “DIAE_HandlerAlarmGroup.ashx”.
CVE-2021-44544
DIAEnergie Version 1.7.5 and prior is vulnerable to multiple cross-site scripting vulnerabilities when arbitrary code is injected into the parameter “name” of the script “HandlerEnergyType.ashx”.