13 matches found
CVE-2022-0988
Delta Electronics DIAEnergie (Version 1.7.5 and prior) is vulnerable to cleartext transmission as the web application runs by default on HTTP. This could allow an attacker to remotely read transmitted information between the client and product.
CVE-2021-38391
A Blind SQL injection vulnerability exists in the /DataHandler/AM/AM_Handler.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter type before using it as part of an SQL query. A rem...
CVE-2021-32955
Delta Electronics DIAEnergie Version 1.7.5 and prior allows unrestricted file uploads, which may allow an attacker to remotely execute code.
CVE-2021-23228
DIAEnergie Version 1.7.5 and prior is vulnerable to a reflected cross-site scripting attack through error pages that are returned by “.NET Request.QueryString”.
CVE-2021-38390
A Blind SQL injection vulnerability exists in the /DataHandler/HandlerEnergyType.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter egyid before using it as part of an SQL query. ...
CVE-2021-38393
A Blind SQL injection vulnerability exists in the /DataHandler/HandlerAlarmGroup.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter agid before using it as part of an SQL query. A...
CVE-2021-32983
A Blind SQL injection vulnerability exists in the /DataHandler/Handler_CFG.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter keyword before using it as part of an SQL query. A re...
CVE-2021-44471
DIAEnergie Version 1.7.5 and prior is vulnerable to stored cross-site scripting when an unauthenticated user injects arbitrary code into the parameter “name” of the script “DIAE_HandlerAlarmGroup.ashx”.
CVE-2021-32967
Delta Electronics DIAEnergie Version 1.7.5 and prior may allow an attacker to add a new administrative user without being authenticated or authorized, which may allow the attacker to log in and use the device with administrative privileges.
CVE-2021-33003
Delta Electronics DIAEnergie Version 1.7.5 and prior may allow an attacker to retrieve passwords in cleartext due to a weak hashing algorithm.
CVE-2021-32991
Delta Electronics DIAEnergie Version 1.7.5 and prior is vulnerable to cross-site request forgery, which may allow an attacker to cause a user to carry out an action unintentionally.
CVE-2021-44544
DIAEnergie Version 1.7.5 and prior is vulnerable to multiple cross-site scripting vulnerabilities when arbitrary code is injected into the parameter “name” of the script “HandlerEnergyType.ashx”.
CVE-2021-31558
DIAEnergie Version 1.7.5 and prior is vulnerable to stored cross-site scripting when an unauthenticated user injects arbitrary code into the parameter “descr” of the script “DIAE_hierarchyHandler.ashx”.