The HTTP service in American Power Conversion (APC) PowerChute uses a default username and password, which allows remote attackers to gain system access.
7.3AI Score
0.003EPSS
APC UPS daemon, apcupsd, saves its process ID in a world-writable file, which allows local users to kill an arbitrary process by specifying the target process ID in the apcupsd.pid file.
6.3AI Score
0.0004EPSS
APC Web/SNMP Management Card prior to Firmware 310 only supports one telnet connection, which allows a remote attacker to create a denial of service via repeated failed logon attempts which temporarily locks the card.
6.9AI Score
0.027EPSS
PowerChute plus 5.0.2 creates a "Pwrchute" directory during installation that is shared and world writeable, which could allow remote attackers to modify or create files in that directory.
7AI Score
0.006EPSS
Multiple buffer overflows in apcupsd before 3.8.6, and 3.10.x before 3.10.5, may allow attackers to cause a denial of service or execute arbitrary code, related to usage of the vsprintf function.
7.1AI Score
0.001EPSS
American Power Conversion (APC) Web/SNMP Management SmartSlot Card 3.0 through 3.0.3 and 3.21 are shipped with a default password of TENmanUFactOryPOWER, which allows remote attackers to gain unauthorized access.
7.8AI Score
0.012EPSS
Unknown vulnerability in APC PowerChute Business Edition 6.0 through 7.0.1 allows remote attackers to cause a denial of service via unknown attack vectors.
6.9AI Score
0.015EPSS
The web interface for American Power Conversion (APC) PowerChute Network Shutdown performs all communication in cleartext (base64-encoded), which allows remote attackers to sniff authentication credentials.
7.3AI Score
0.006EPSS
The American Power Conversion (APC) AP7932 0u 30amp Switched Rack Power Distribution Unit (PDU), with rpdu 3.5.5 and aos 3.5.6, allows remote attackers to bypass authentication and obtain login access by making a login attempt while a different client is logged in, and then resubmitting the login a...
7AI Score
0.063EPSS
Multiple cross-site request forgery (CSRF) vulnerabilities on the Network Management Card (NMC) on American Power Conversion (APC) Switched Rack PDU (aka Rack Mount Power Distribution) devices and other devices allow remote attackers to hijack the authentication of (1) administrator or (2) device u...
7.8AI Score
0.002EPSS
Multiple cross-site scripting (XSS) vulnerabilities on the Network Management Card (NMC) on American Power Conversion (APC) Switched Rack PDU (aka Rack Mount Power Distribution) devices and other devices allow remote attackers to inject arbitrary web script or HTML via unspecified vectors. NOTE: th...
6AI Score
0.004EPSS
Cross-site scripting (XSS) vulnerability in Forms/login1 in American Power Conversion (APC) Switched Rack PDU AP7932 B2, running rpdu 3.3.3 or 3.7.0 on AOS 3.3.4, and possibly other versions, allows remote attackers to inject arbitrary web script or HTML via the login_username parameter.
5.8AI Score
0.004EPSS
Cross-site scripting (XSS) vulnerability in Schneider Electric PowerChute Business Edition before 8.5 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
5.7AI Score
0.001EPSS
Improper Input Validation vulnerability exists in PowerChute Business Edition (software V9.0.x and earlier) which could cause remote code execution when a script is executed during a shutdown event.
8.8CVSS
8.8AI Score