Lucene search

K

Abb Security Vulnerabilities

cve
cve

CVE-2008-2474

Buffer overflow in x87 before 3.5.5 in ABB Process Communication Unit 400 (PCU400) 4.4 through 4.6 allows remote attackers to execute arbitrary code via a crafted packet using the (1) IEC60870-5-101 or (2) IEC60870-5-104 communication protocol to the X87 web interface.

7.8AI Score

0.052EPSS

2008-09-29 05:17 PM
41
cve
cve

CVE-2012-0245

Multiple stack-based buffer overflows in RobNetScanHost.exe in ABB Robot Communications Runtime before 5.14.02, as used in ABB Interlink Module, IRC5 OPC Server, PC SDK, PickMaster 3 and 5, RobView 5, RobotStudio, WebWare SDK, and WebWare Server, allow remote attackers to execute arbitrary code via...

7.7AI Score

0.188EPSS

2012-03-09 11:55 AM
120
cve
cve

CVE-2012-1801

Multiple stack-based buffer overflows in (1) COM and (2) ActiveX controls in ABB WebWare Server, WebWare SDK, Interlink Module, S4 OPC Server, QuickTeach, RobotStudio S4, and RobotStudio Lite allow remote attackers to execute arbitrary code via crafted input data.

8.1AI Score

0.012EPSS

2012-04-18 10:33 AM
30
cve
cve

CVE-2013-5021

Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote ...

7.5AI Score

0.898EPSS

2013-08-06 08:55 PM
36
cve
cve

CVE-2014-5430

Untrusted search path vulnerability in ABB RobotStudio 5.6x before 5.61.02 and Test Signal Viewer 1.5 allows local users to gain privileges via a Trojan horse DLL that is accessed as a result of incorrect DLL configuration by an optional installation program.

6.7AI Score

0.001EPSS

2014-11-07 11:55 AM
34
cve
cve

CVE-2016-2281

Untrusted search path vulnerability in ABB Panel Builder 800 5.1 allows local users to gain privileges via a Trojan horse DLL in the current working directory.

7.2CVSS

6.9AI Score

0.0004EPSS

2016-03-18 02:59 PM
35
cve
cve

CVE-2016-4511

ABB PCM600 before 2.7 uses an improper hash algorithm for the main application password, which makes it easier for local users to obtain sensitive cleartext information by leveraging read access to the ACTConfig configuration file.

2.8CVSS

3.4AI Score

0.0004EPSS

2016-06-10 01:59 AM
32
cve
cve

CVE-2016-4516

ABB PCM600 before 2.7 improperly stores the main application password after a password change, which allows local users to obtain sensitive information via unspecified vectors.

3.3CVSS

3.7AI Score

0.0004EPSS

2016-06-10 01:59 AM
29
cve
cve

CVE-2016-4524

ABB PCM600 before 2.7 improperly stores OPC Server IEC61850 passwords in unspecified temporary circumstances, which allows local users to obtain sensitive information via unknown vectors.

6.5CVSS

6AI Score

0.0004EPSS

2016-06-10 01:59 AM
29
cve
cve

CVE-2016-4527

ABB PCM600 before 2.7 improperly stores PCM600 authentication credentials, which allows local users to obtain sensitive information via unspecified vectors.

3.3CVSS

3.7AI Score

0.0004EPSS

2016-06-10 01:59 AM
71
cve
cve

CVE-2017-7906

In ABB IP GATEWAY 3.39 and prior, the web server does not sufficiently verify that a request was performed by the authenticated user, which may allow an attacker to launch a request impersonating that user.

8.8CVSS

8.4AI Score

0.001EPSS

2018-06-06 08:29 PM
41
cve
cve

CVE-2017-7916

A Permissions, Privileges, and Access Controls issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. The web application does not properly restrict privileges of the Guest account. A malicious user may be able ...

6.5CVSS

6.4AI Score

0.001EPSS

2017-08-07 08:29 AM
36
cve
cve

CVE-2017-7920

An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information...

7.5CVSS

7.4AI Score

0.002EPSS

2017-08-07 08:29 AM
35
cve
cve

CVE-2017-7931

In ABB IP GATEWAY 3.39 and prior, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the configuration files and application pages without authentication.

9.8CVSS

9.3AI Score

0.002EPSS

2018-06-06 08:29 PM
39
cve
cve

CVE-2017-7933

In ABB IP GATEWAY 3.39 and prior, some configuration files contain passwords stored in plain-text, which may allow an attacker to gain unauthorized access.

9.8CVSS

9.3AI Score

0.002EPSS

2018-06-06 08:29 PM
39
cve
cve

CVE-2017-9664

In ABB SREA-01 revisions A, B, C: application versions up to 3.31.5, and SREA-50 revision A: application versions up to 3.32.8, an attacker may access internal files of ABB SREA-01 and SREA-50 legacy remote monitoring tools without any authorization over the network using a HTTP request which refer...

9.8CVSS

9.6AI Score

0.002EPSS

2018-05-24 08:29 PM
34
cve
cve

CVE-2018-10616

ABB Panel Builder 800 all versions has an improper input validation vulnerability which may allow an attacker to insert and run arbitrary code on a computer where the affected product is used.

7.8CVSS

7.4AI Score

0.021EPSS

2018-07-18 03:29 PM
40
cve
cve

CVE-2018-17926

The product M2M ETHERNET (FW Versions 2.22 and prior, ETH-FW Versions 1.01 and prior) is vulnerable in that an attacker can upload a malicious language file by bypassing the user authentication mechanism.

4.3CVSS

4.7AI Score

0.0005EPSS

2019-01-31 05:29 PM
42
cve
cve

CVE-2018-17928

The product CMS-770 (Software Versions 1.7.1 and prior)is vulnerable that an attacker can read sensitive configuration files by bypassing the user authentication mechanism.

6.5CVSS

6.5AI Score

0.0005EPSS

2019-01-31 09:29 PM
42
cve
cve

CVE-2018-18995

Pluto Safety PLC Gateway Ethernet devices ABB GATE-E1 and GATE-E2 all versions do not allow authentication to be configured on administrative telnet or web interfaces, which could enable various effects vectors, including conducting device resets, reading or modifying registers, and changing config...

9.8CVSS

9.5AI Score

0.002EPSS

2019-01-03 10:29 PM
39
cve
cve

CVE-2018-18997

Pluto Safety PLC Gateway Ethernet devices in ABB GATE-E1 and GATE-E2 all versions allows an unauthenticated attacker using the administrative web interface to insert an HTML/Javascript payload into any of the device properties, which may allow an attacker to display/execute the payload in a visitor...

6.1CVSS

6.3AI Score

0.001EPSS

2019-01-03 10:29 PM
38
cve
cve

CVE-2018-19008

The TextEditor 2.0 in ABB CP400 Panel Builder versions 2.0.7.05 and earlier contain a vulnerability in the file parser of the Text Editor wherein the application doesn't properly prevent the insertion of specially crafted files which could allow arbitrary code execution.

7.8CVSS

7.8AI Score

0.001EPSS

2019-02-13 09:29 PM
31
cve
cve

CVE-2018-5477

An Information Exposure issue was discovered in ABB netCADOPS Web Application Version 3.4 and prior, netCADOPS Web Application Version 7.1 and prior, netCADOPS Web Application Version 7.2x and prior, netCADOPS Web Application Version 8.0 and prior, and netCADOPS Web Application Version 8.1 and prio...

5.8CVSS

5.7AI Score

0.001EPSS

2018-02-20 07:29 PM
29
2
cve
cve

CVE-2019-10953

ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.

7.5CVSS

7.4AI Score

0.001EPSS

2019-04-17 03:29 PM
62
2
cve
cve

CVE-2019-10995

ABB CP651 HMI products revision BSP UN30 v1.76 and prior implement hidden administrative accounts that are used during the provisioning phase of the HMI interface.

8.8CVSS

8.7AI Score

0.001EPSS

2020-01-14 05:15 PM
32
cve
cve

CVE-2019-18250

In all versions of ABB Power Generation Information Manager (PGIM) and Plant Connect, the affected product is vulnerable to authentication bypass, which may allow an attacker to remotely bypass authentication and extract credentials from the affected device.

9.8CVSS

9.4AI Score

0.004EPSS

2019-11-26 12:15 AM
53
cve
cve

CVE-2019-18994

Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when trying to load an empty *.JPR application file. An attacker with access to the file system might be able to cause application malfunction such as denial of service.

6.5CVSS

6.2AI Score

0.001EPSS

2019-12-18 09:15 PM
30
cve
cve

CVE-2019-18995

The HMISimulator component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier fails to validate the content-length field for HTTP requests, exposing HMISimulator to denial of service via crafted HTTP requests manipulating the content-length setting.

5.3CVSS

5.2AI Score

0.001EPSS

2019-12-18 09:15 PM
28
cve
cve

CVE-2019-18996

Path settings in HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier accept DLLs outside of the program directory, potentially allowing an attacker with access to the local file system the execution of code in the application’s context.

7.8CVSS

7.5AI Score

0.001EPSS

2019-12-18 09:15 PM
37
cve
cve

CVE-2019-18997

The HMISimulator component of ABB PB610 Panel Builder 600 uses the readFile/writeFile interface to manipulate the work file. Path configuration in PB610 HMISimulator versions 2.8.0.424 and earlier potentially allows access to files outside of the working directory, thus potentially supporting unaut...

7.5CVSS

7.3AI Score

0.003EPSS

2019-12-18 09:15 PM
34
cve
cve

CVE-2019-19104

The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sen...

9.8CVSS

9AI Score

0.003EPSS

2020-04-22 03:15 PM
36
cve
cve

CVE-2019-19105

The backup function in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway saves the current settings and configuration of the application, including credentials of existing user accounts and other configuration's credentials in plaintext.

6.2CVSS

5.5AI Score

0.0004EPSS

2020-04-22 03:15 PM
21
cve
cve

CVE-2019-19106

Improper implementation of Access Control in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows an unauthorized user to access data marked as restricted, such as viewing or editing user profiles and application settings.

9.1CVSS

9AI Score

0.002EPSS

2020-04-22 03:15 PM
35
cve
cve

CVE-2019-19107

The Configuration pages in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway for user profiles and services transfer the password in plaintext (although hidden when displayed).

6.2CVSS

5.6AI Score

0.0004EPSS

2020-04-22 03:15 PM
31
cve
cve

CVE-2019-7225

The ABB HMI components implement hidden administrative accounts that are used during the provisioning phase of the HMI interface. These credentials allow the provisioning tool "Panel Builder 600" to flash a new interface and Tags (MODBUS coils) mapping to the HMI. These credentials are the idal123 ...

8.8CVSS

8.7AI Score

0.002EPSS

2019-06-27 05:15 PM
64
cve
cve

CVE-2019-7226

The ABB IDAL HTTP server CGI interface contains a URL that allows an unauthenticated attacker to bypass authentication and gain access to privileged functions. Specifically, /cgi/loginDefaultUser creates a session in an authenticated state and returns the session ID along with what may be the usern...

8.8CVSS

8.9AI Score

0.003EPSS

2019-06-27 04:15 PM
43
2
cve
cve

CVE-2019-7227

In the ABB IDAL FTP server, an authenticated attacker can traverse to arbitrary directories on the hard disk with "CWD ../" and then use the FTP server functionality to download and upload files. An unauthenticated attacker can take advantage of the hardcoded or default credential pair exor/exor to...

7.3CVSS

7.2AI Score

0.001EPSS

2019-06-27 04:15 PM
36
2
cve
cve

CVE-2019-7228

The ABB IDAL HTTP server mishandles format strings in a username or cookie during the authentication process. Attempting to authenticate with the username %25s%25p%25x%25n will crash the server. Sending %08x.AAAA.%08x.%08x will log memory content from the stack.

8.8CVSS

8.6AI Score

0.021EPSS

2019-06-27 03:15 PM
36
2
cve
cve

CVE-2019-7229

The ABB CP635 HMI uses two different transmission methods to upgrade its firmware and its software components: "Utilization of USB/SD Card to flash the device" and "Remote provisioning process via ABB Panel Builder 600 over FTP." Neither of these transmission methods implements any form of encrypti...

8.3CVSS

8.2AI Score

0.006EPSS

2019-06-24 06:15 PM
64
cve
cve

CVE-2019-7230

The ABB IDAL FTP server mishandles format strings in a username during the authentication process. Attempting to authenticate with the username %s%p%x%d will crash the server. Sending %08x.AAAA.%08x.%08x will log memory content from the stack.

8.8CVSS

8.6AI Score

0.095EPSS

2019-06-24 05:15 PM
57
2
cve
cve

CVE-2019-7231

The ABB IDAL FTP server is vulnerable to a buffer overflow when a long string is sent by an authenticated attacker. This overflow is handled, but terminates the process. An authenticated attacker can send a FTP command string of 472 bytes or more to overflow a buffer, causing an exception that term...

5.7CVSS

5.8AI Score

0.001EPSS

2019-06-24 08:15 PM
42
2
cve
cve

CVE-2019-7232

The ABB IDAL HTTP server is vulnerable to a buffer overflow when a long Host header is sent in a web request. The Host header value overflows a buffer and overwrites a Structured Exception Handler (SEH) address. An unauthenticated attacker can submit a Host header value of 2047 bytes or more to ove...

8.8CVSS

9.1AI Score

0.009EPSS

2019-06-24 05:15 PM
62
2
cve
cve

CVE-2020-10287

The IRC5 family with UAS service enabled comes by default with credentials that can be found on publicly available manuals. ABB considers this a well documented functionality that helps customer set up however, out of our research, we found multiple production systems running these exact default cr...

9.8CVSS

9.3AI Score

0.002EPSS

2020-07-15 11:15 PM
28
cve
cve

CVE-2020-10288

IRC5 exposes an ftp server (port 21). Upon attempting to gain access you are challenged with a request of username and password, however you can input whatever you like. As long as the field isn't empty it will be accepted.

9.8CVSS

9.4AI Score

0.003EPSS

2020-07-15 11:15 PM
55
4
cve
cve

CVE-2020-11420

UPS Adapter CS141 before 1.90 allows Directory Traversal. An attacker with Admin or Engineer login credentials could exploit the vulnerability by manipulating variables that reference files and by doing this achieve access to files and directories outside the web root folder. An attacker may access...

6.5CVSS

6.3AI Score

0.001EPSS

2020-04-27 02:15 PM
27
cve
cve

CVE-2020-24672

A vulnerability in Base Software for SoftControl allows an attacker to insert and run arbitrary code in a computer running the affected product. This issue affects: .

9.8CVSS

9.3AI Score

0.002EPSS

2021-09-08 04:15 PM
25
2
cve
cve

CVE-2020-24673

In S+ Operations and S+ Historian, a successful SQL injection exploit can read sensitive data from the database, modify database data (Insert/Update/Delete), execute administration operations on the database (such as shutdown the DBMS), recover the content of a given file present on the DBMS file s...

9.8CVSS

9.7AI Score

0.002EPSS

2020-12-22 10:15 PM
52
cve
cve

CVE-2020-24674

In S+ Operations and S+ Historian, not all client commands correctly check user permission as expected. Authenticated but Unauthorized remote users could execute a Denial-of-Service (DoS) attack, execute arbitrary code, or obtain more privilege than intended on the machines.

8.8CVSS

8.9AI Score

0.005EPSS

2020-12-22 10:15 PM
39
2
cve
cve

CVE-2020-24675

In S+ Operations and S+ History, it is possible that an unauthenticated user could inject values to the Operations History server (or standalone S+ History server) and ultimately write values to the controlled process.

9.8CVSS

9.4AI Score

0.003EPSS

2020-12-22 10:15 PM
46
cve
cve

CVE-2020-24676

In Symphony Plus Operations and Symphony Plus Historian, some services can be vulnerable to privilege escalation attacks. An unprivileged (but authenticated) user could execute arbitrary code and result in privilege escalation, depending on the user that the service runs as.

7.8CVSS

8AI Score

0.0004EPSS

2020-12-22 10:15 PM
45
Total number of security vulnerabilities125