Lucene search

K

Simatic Pcs7 Security Vulnerabilities

cve
cve

CVE-2012-3015

Untrusted search path vulnerability in Siemens SIMATIC STEP7 before 5.5 SP1, as used in SIMATIC PCS7 7.1 SP3 and earlier and other products, allows local users to gain privileges via a Trojan horse DLL in a STEP7 project folder.

6.7AI Score

0.001EPSS

2012-07-26 10:41 AM
47
4
cve
cve

CVE-2012-3028

Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service.

7.5AI Score

0.002EPSS

2012-09-18 02:55 PM
31
cve
cve

CVE-2012-3030

WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, stores sensitive information under the web root with insufficient access control, which allows remote attackers to read a (1) log file or (2) configuration file via a direct request.

6.4AI Score

0.003EPSS

2012-09-18 02:55 PM
24
cve
cve

CVE-2012-3031

Multiple cross-site scripting (XSS) vulnerabilities in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allow remote attackers to inject arbitrary web script or HTML via a (1) GET parameter, (2) POST parameter, or (3) Referer HTTP header.

5.8AI Score

0.002EPSS

2012-09-18 02:55 PM
31
cve
cve

CVE-2012-3032

SQL injection vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to execute arbitrary SQL commands via a crafted SOAP message.

8.4AI Score

0.002EPSS

2012-09-18 02:55 PM
38
cve
cve

CVE-2012-3034

WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to discover a username and password via crafted parameters to unspecified methods in ActiveX controls.

7AI Score

0.003EPSS

2012-09-18 02:55 PM
25
cve
cve

CVE-2013-0674

Buffer overflow in the RegReader ActiveX control in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to execute arbitrary code via a long parameter.

8.1AI Score

0.233EPSS

2013-03-21 03:55 PM
117
cve
cve

CVE-2013-0675

Buffer overflow in CCEServer (aka the central communications component) in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to cause a denial of service via a crafted packet.

7AI Score

0.002EPSS

2013-03-21 03:55 PM
28
cve
cve

CVE-2013-0676

Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly assign privileges for the database containing WebNavigator credentials, which allows remote authenticated users to obtain sensitive information via a SQL query.

6.3AI Score

0.001EPSS

2013-03-21 03:55 PM
34
cve
cve

CVE-2013-0677

The web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote attackers to obtain sensitive information or cause a denial of service via a crafted project file.

6.7AI Score

0.004EPSS

2013-03-21 03:55 PM
30
cve
cve

CVE-2013-0678

Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, does not properly represent WebNavigator credentials in a database, which makes it easier for remote authenticated users to obtain sensitive information via a SQL query.

6.2AI Score

0.001EPSS

2013-03-21 03:55 PM
31
cve
cve

CVE-2013-0679

Directory traversal vulnerability in the web server in Siemens WinCC before 7.2, as used in SIMATIC PCS7 before 8.0 SP1 and other products, allows remote authenticated users to read arbitrary files via vectors involving a query for a pathname.

6.4AI Score

0.001EPSS

2013-03-21 03:55 PM
31
cve
cve

CVE-2013-3957

SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors.

8.5AI Score

0.002EPSS

2013-06-14 07:55 PM
26
cve
cve

CVE-2013-3958

The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request.

6.8AI Score

0.005EPSS

2013-06-14 07:55 PM
31
cve
cve

CVE-2013-3959

The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL...

6.4AI Score

0.001EPSS

2013-06-14 07:55 PM
29
cve
cve

CVE-2014-4682

The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request.

6.2AI Score

0.003EPSS

2014-07-24 02:55 PM
35
cve
cve

CVE-2014-4683

The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request.

6.6AI Score

0.001EPSS

2014-07-24 02:55 PM
27
cve
cve

CVE-2014-4684

The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433.

6.6AI Score

0.002EPSS

2014-07-24 02:55 PM
28
cve
cve

CVE-2014-4685

Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control.

6.6AI Score

0.0004EPSS

2014-07-24 02:55 PM
32
cve
cve

CVE-2014-4686

The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during t...

6.1AI Score

0.004EPSS

2014-07-24 02:55 PM
33
cve
cve

CVE-2014-8551

The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets.

7.7AI Score

0.015EPSS

2014-11-26 11:59 AM
38
cve
cve

CVE-2014-8552

The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets.

6.8AI Score

0.003EPSS

2014-11-26 11:59 AM
33
cve
cve

CVE-2016-7165

A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (Al...

6.4CVSS

6.9AI Score

0.001EPSS

2016-11-15 07:30 PM
34
cve
cve

CVE-2017-12069

An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC WinCC (All versions < V7.4 SP1), SIMATIC WinCC Runtime ...

8.2CVSS

8AI Score

0.006EPSS

2017-08-30 07:29 PM
62
cve
cve

CVE-2017-14023

An Improper Input Validation issue was discovered in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V7.3 Upd 13, and V8.2 all versions. The improper input validation vulnerability has been identified, which may allow an authenticated remote attacker who is a member of the administrators gr...

4.9CVSS

5AI Score

0.002EPSS

2017-11-06 10:29 PM
44