76 matches found
CVE-2021-36260
CVE-2021-36260 CVE-2021-36260 ./CVE-2021-36260.py --rhost 192.168.57.20 --rport 8080 --check 안전 및 비안전 취약점/검증 점검: '안전 점검'으로 검증되지 않은 경우에만 '비안전 점검'을 사용합니다 $./CVE-2021-36260.py --rhost 192.168.57.20 --rport 8080 --check --reboot 비안전 취약점/검증 점검: $./CVE-2021-36260.py --rhost 192.168.57.20 --rport 8080...
CVE-2022-30525_check
CVE-2022-30525check Description: Ce script vérifie la présence de la vulnérabilité d'injection de commandes système CVE-2022-30525 sur les appareils Zyxel USG FLEX exécutant les versions de firmware 5.00 à 5.21 Patch 1. La vulnérabilité permet à un attaquant de modifier des fichiers spécifiques e...
CVE-2022-30525
CVE-2022-30525 Injection de commandes à distance dans le pare-feu Zyxel Un exploit basé sur python pour CVE-2022-30525 Résumé de la vulnérabilité NIST Une vulnérabilité d'injection de commandes OS dans le programme CGI des versions de firmware Zyxel USG FLEX 100W de 5.00 à 5.21 Patch 1 incluse, d...
CVE-2022-30525_Exploit
CVE-2022-30525 Injection de commandes à distance dans le pare-feu Zyxel Un exploit basé sur Python pour CVE-2022-30525 Résumé de la vulnérabilité NIST Une vulnérabilité d'injection de commandes OS dans le programme CGI des versions de firmware Zyxel USG FLEX 100W 5.00 jusqu'à 5.21 Patch 1 inclus,...
CVE-2026-14818
CVE-2026-14818 describes a path traversal vulnerability in the CLI command used to execute configuration files on Zyxel devices. Affected firmware ranges include Zyxel ATP series (V4.32–V5.42 Patch 1), USG FLEX series (V4.50–V5.42 Patch 1), USG FLEX 50(W) series (V4.16–V5.42 Patch 1), and USG20(W...
CVE-2025-9133
Summary of CVE-2025-9133 (Zyxel devices) Technical details in the connected PT-2025-42828 entry show a missing authorization flaw in Zyxel ATP series, Zyxel USG FLEX series, and Zyxel USG20(W)-VPN devices. The vulnerability arises from insufficient input validation/logic in the CGI interface, spe...
CVE-2025-8078
A post-authentication command injection vulnerability in Zyxel ATP series firmware versions from V4.32 through V5.40, USG FLEX series firmware versions from V4.50 through V5.40, USG FLEX 50W series firmware versions from V4.16 through V5.40, and USG20W-VPN series firmware versions from V4.16...
CVE-2025-8078
A post-authentication command injection vulnerability in Zyxel ATP series firmware versions from V4.32 through V5.40, USG FLEX series firmware versions from V4.50 through V5.40, USG FLEX 50W series firmware versions from V4.16 through V5.40, and USG20W-VPN series firmware versions from V4.16...
PT-2025-42828
Name of the Vulnerable Software and Affected Versions Zyxel ATP series versions V4.32 through V5.40 Zyxel USG FLEX series versions V4.50 through V5.40 Zyxel USG FLEX 50W series versions V4.16 through V5.40 Zyxel USG20W-VPN series versions V4.16 through V5.40 Description A missing authorization fl...
EUVD-2023-27017
Malicious code in bioql PyPI...
EUVD-2023-27015
Malicious code in bioql PyPI...
EUVD-2025-12140
Malicious code in bioql PyPI...
EUVD-2023-58231
Malicious code in bioql PyPI...
EUVD-2023-27016
Malicious code in bioql PyPI...
EUVD-2023-38241
Malicious code in bioql PyPI...
EUVD-2025-12335
Malicious code in bioql PyPI...
CVE-2023-22914
A path traversal vulnerability in the “accountprint.cgi” CGI program of Zyxel USG FLEX series firmware versions 4.50 through 5.35, and VPN series firmware versions 4.30 through 5.35, which could allow a remote authenticated attacker with administrator privileges to execute unauthorized OS command...
CVE-2023-5960
An improper privilege management vulnerability in the hotspot feature of the Zyxel USG FLEX series firmware versions 4.50 through 5.37 and VPN series firmware versions 4.30 through 5.37 could allow an authenticated local attacker to access the system files on an affected device...
Zyxel USG FLEX H Series Firewall 1.20 < 1.32 Privilege Escalation
Firmware version of the Zyxel USG is less than uOS 1.32. This means the Zyxel device is vulnerable to mualtiple privilege escalation vulnerability. The incorrect permission assignment vulnerability in the PostgreSQL commands of certain USG FLEX H series uOS firmware versions could allow an...
Zyxel USG FLEX H Series Firewall < 1.30 Privilege Escalation
Firmware version of the Zyxel USG is less than uOS 1.30. This means the Zyxel device is vulnerable to a privilege escalation vulnerability. The insufficiently protected credentials vulnerability in the CLI command of the USG FLEX H series firewalls could allow an authenticated local attacker to...