Lucene search
K

8 matches found

RedhatCVE
RedhatCVE
added 2026/01/09 12:11 p.m.10 views

CVE-2018-18881

A Denial of Service DOS issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can configure invalid network settings, stopping TCP based communications to the device. A physical factory rese...

6.8CVSS6.6AI score0.016EPSS
Exploits0References1
RedhatCVE
RedhatCVE
added 2026/01/09 12:9 p.m.7 views

CVE-2018-18882

A stored cross-site scripting XSS issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can inject arbitrary script via setup.html in the web interface...

5.4CVSS5.7AI score0.00746EPSS
Exploits1References1
NVD
NVD
added 2019/03/21 4:0 p.m.14 views

CVE-2018-18881

A Denial of Service DOS issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can configure invalid network settings, stopping TCP based communications to the device. A physical factory rese...

6.8CVSS6.2AI score0.016EPSS
Exploits0References2
NVD
NVD
added 2019/03/21 4:0 p.m.28 views

CVE-2018-18882

A stored cross-site scripting XSS issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can inject arbitrary script via setup.html in the web interface...

5.4CVSS5.5AI score0.00746EPSS
Exploits1References2
OSV
OSV
added 2019/03/21 4:0 p.m.2 views

CVE-2018-18881

A Denial of Service DOS issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can configure invalid network settings, stopping TCP based communications to the device. A physical factory rese...

6.5CVSS5.8AI score0.016EPSS
Exploits0References2
Prion
Prion
added 2019/03/21 4:0 p.m.23 views

Design/Logic Flaw

A Denial of Service DOS issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can configure invalid network settings, stopping TCP based communications to the device. A physical factory rese...

6.8CVSS6.2AI score0.016EPSS
Exploits0References2Affected Software1
Cvelist
Cvelist
added 2019/03/17 9:9 p.m.27 views

CVE-2018-18881

A Denial of Service DOS issue was discovered in ControlByWeb X-320M-I Web-Enabled Instrumentation-Grade Data Acquisition module 1.05 with firmware revision v1.05. An authenticated user can configure invalid network settings, stopping TCP based communications to the device. A physical factory rese...

6.2AI score0.016EPSS
Exploits0References2
CVE
CVE
added 2019/03/17 9:9 p.m.43 views

CVE-2018-18881

CVE-2018-18881 affects ControlByWeb X-320M-I (firmware v1.05 and earlier). The issue is a Denial of Service caused by an authenticated user configuring invalid network settings, which stops TCP communications and requires a physical factory reset to recover. Red Hat and NVD entries corroborate th...