Lucene search
+L

89 matches found

ICS
ICS
added 2013/07/04 6:00 a.m.43 views

Siemens SCALANCE X-200 Authentication Bypass Vulnerability

OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on October 01, 2013, and is now being released to the ICS-CERT-Web page. Siemens has identified an authentication bypass vulnerability in the SCALANCE X-200 switch product family. Researcher Eireann Leverett of...

10CVSS6.7AI score0.03203EPSS
SaveExploits0References10
ICS
ICS
added 2013/06/14 6:00 a.m.63 views

Siemens SCALANCE X-200 Web Hijack Vulnerability

OVERVIEW Siemens has identified a Web hijack vulnerability in the SCALANCE X-200 switch product family. Researcher Eireann Leverett of IOActive coordinated disclosure of the vulnerability with Siemens. Siemens has produced a firmware update that mitigates this vulnerability. This vulnerability...

8.3CVSS6.3AI score0.02988EPSS
SaveExploits0References10
NVD
NVD
added 2013/05/24 8:55 p.m.26 views

CVE-2013-3634

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants Versions V5.0.0 for CVE-2013-3633 and versions V4.5.0 for CVE-2013-3634, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.1.0. The implementation of SNMPv3 does not check the use...

7.5CVSS6.6AI score0.01445EPSS
SaveExploits0References1
NVD
NVD
added 2013/05/24 8:55 p.m.18 views

CVE-2013-3633

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants Versions V5.0.0 for CVE-2013-3633 and versions V4.5.0 for CVE-2013-3634, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.1.0. The user privileges for the web interface are only...

8CVSS6.6AI score0.01197EPSS
SaveExploits0References1
Prion
Prion
added 2013/05/24 8:55 p.m.18 views

Command injection

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants Versions V5.0.0 for CVE-2013-3633 and versions V4.5.0 for CVE-2013-3634, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.1.0. The implementation of SNMPv3 does not check the use...

7.5CVSS6.9AI score0.01445EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2013/05/24 8:55 p.m.21 views

Design/Logic Flaw

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants Versions V5.0.0 for CVE-2013-3633 and versions V4.5.0 for CVE-2013-3634, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.1.0. The user privileges for the web interface are only...

8CVSS6.9AI score0.01445EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2013/05/24 8:00 p.m.42 views

CVE-2013-3634

A vulnerability has been identified in SCALANCE X-200 switch family incl. SIPLUS NET variants Versions V5.0.0 for CVE-2013-3633 and versions V4.5.0 for CVE-2013-3634, SCALANCE X-200IRT switch family incl. SIPLUS NET variants All versions V5.1.0. The implementation of SNMPv3 does not check the use...

6.6AI score0.01445EPSS
SaveExploits0References1
CVE
CVE
added 2013/05/24 8:00 p.m.61 views

CVE-2013-3634

Summary (concrete details present): Siemens SCALANCE X-200 and X-200IRT switches (incl. SIPLUS NET variants) are affected by two CVEs (CVE-2013-3633 and CVE-2013-3634). Root cause: SNMPv3 does not sufficiently check user credentials, enabling command execution via SNMP commands, and web interface...

7.5CVSS6.8AI score0.01445EPSS
SaveExploits0References1Affected Software7
CVE
CVE
added 2013/05/24 8:00 p.m.65 views

CVE-2013-3633

Siemens SCALANCE X-200 and X-200IRT switches are affected by two related vulnerabilities (CVE-2013-3633 and CVE-2013-3634). The root cause is that web interface user privileges are enforced only on the client side and not properly verified on the server side (privilege escalation), and the SNMPv3...

8CVSS6.8AI score0.01197EPSS
SaveExploits0References1Affected Software7
Rows per page