46 matches found
EUVD-2022-33828
Malicious code in bioql PyPI...
EUVD-2024-44446
Malicious code in bioql PyPI...
EUVD-2022-25059
Malicious code in bioql PyPI...
The vulnerability of the software for the Hitachi Energy MicroSCADA X SYS600 system, related to insecure management of privileges, allows a perpetrator to disclose protected information.
The vulnerability of the software used in the Hitachi Energy MicroSCADA X SYS600 equipment management system is related to insecure management of privileges. Exploiting this vulnerability could allow an attacker to disclose protected information...
CVE-2025-39205
A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product. The certificate validation of the TLS protocol allows remote Man-in-the-Middle attack due to missing proper validation...
CVE-2025-39205
A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product. The certificate validation of the TLS protocol allows remote Man-in-the-Middle attack due to missing proper validation...
CVE-2025-39205
A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product. The certificate validation of the TLS protocol allows remote Man-in-the-Middle attack due to missing proper validation...
CVE-2025-39204
The CVE-2025-39204 entry affects Hitachi MicroSCADA X SYS600, specifically a vulnerability in the Web interface where a malformed filtering query can leak file content via the Web UI. Affected component: the Web interface filtering logic; root cause: malformed queries exposing data. Impact: infor...
CVE-2025-39203
The CVE-2025-39203 entry concerns the IEC 61850 component of Hitachi Energy’s MicroSCADA X SYS600. The connected documents provide concrete details: a crafted IEC 61850-8 message from an IED or remote system can cause a denial of service, resulting in a disconnection loop in SYS600. The issue is ...
Hitachi Energy MicroSCADA X SYS600 安全漏洞
Hitachi MicroSCADA X SYS600 is a Hitachi Energy MicroSCADA X SYS600, a data acquisition and monitoring control system primarily used in power systems. A security vulnerability exists in Hitachi Energy MicroSCADA X SYS600 that originates from a denial of service due to improper handling of IEC...
PT-2025-26716 · Unknown · Microscada X Sys600
Name of the Vulnerable Software and Affected Versions: MicroSCADA X SYS600 affected versions not specified Description: A vulnerability exists in the Monitor Pro interface of the MicroSCADA X SYS600 product, allowing an authenticated user with low privileges to see and overwrite files. This can...
PT-2025-26718 · Unknown · Microscada X Sys600
Name of the Vulnerable Software and Affected Versions: MicroSCADA X SYS600 affected versions not specified Description: A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product, where an IEC 61850-8 crafted message content from IED or remote system can cause a denial of service,...
PT-2025-26719 · Unknown · Microscada X Sys600
Name of the Vulnerable Software and Affected Versions: MicroSCADA X SYS600 affected versions not specified Description: A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product, where the filtering query can be malformed, leading to unauthorized information leakage to the...
CVE-2024-3982
An attacker with local access to machine where MicroSCADA X SYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already established session. By default, the session logging level is not enabled and only users with administrator...
CVE-2024-3982
An attacker with local access to machine where MicroSCADA X SYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already established session. By default, the session logging level is not enabled and only users with administrator...
CVE-2024-3982
An attacker with local access to machine where MicroSCADA X SYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already established session. By default, the session logging level is not enabled and only users with administrator...
PT-2024-28675 · Unknown · Microscada Pro/X Sys600
Name of the Vulnerable Software and Affected Versions: MicroSCADA Pro/X SYS600 affected versions not specified Description: The product allows an authenticated user input to control or influence paths or file names that are used in filesystem operations. If exploited, this issue allows the attack...
Hitachi Energy MicroSCADA X SYS600 安全漏洞
Hitachi Energy MicroSCADA X SYS600 is a SCADA product from Hitachi, Japan. It ensures optimal control and reliable operation of your switching station through seamless integration and connectivity between different devices and systems. A security vulnerability exists in Hitachi Energy MicroSCADA ...
PT-2024-38706 · Hitachi Energy · Microscada X Sys600
Name of the Vulnerable Software and Affected Versions: No specific software or versions are mentioned in the provided descriptions. Description: The issue allows an HTTP parameter to contain a URL value, which can cause the web application to redirect the request to the specified URL. An attacker...
PT-2024-8680 · Unknown · Microscada X Sys600
Name of the Vulnerable Software and Affected Versions: MicroSCADA X SYS600 affected versions not specified Description: The issue is related to bypassing the authentication procedure in the MicroSCADA X SYS600 system. An attacker with local access to the machine where MicroSCADA X SYS600 is...