Lucene search
+L

158 matches found

RedhatCVE
RedhatCVE
added 2025/05/22 10:8 p.m.14 views

CVE-2022-22809

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk V2.6.2 and prior, Wiser for KNX formerly...

5.3CVSS6.9AI score0.00778EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 10:8 p.m.11 views

CVE-2022-22810

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to manipulate the admin after numerous attempts at guessing credentials. Affected Product: spaceLYnk V2.6.2 and prior, Wiser for KNX formerly homeLYnk V2.6.2 and prior, fellerLYn...

9.8CVSS7AI score0.01091EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 8:31 p.m.9 views

CVE-2021-22806

A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a malicious website. Affected Product: spaceLYnk V2.6.1 and prior, Wiser for KNX V2.6.1 and prior, fellerLYnk V2.6.1 and prior...

7.5CVSS6.9AI score0.00954EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 4:48 p.m.17 views

CVE-2020-7525

Improper Restriction of Excessive Authentication Attempts vulnerability exists in all hardware versions of spaceLYnk and Wiser for KNX formerly homeLYnk which could allow an attacker to guess a password when brute force is used...

7.5CVSS7.1AI score0.01484EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/05/22 8:48 a.m.10 views

CVE-2019-6832

A CWE-287: Authentication vulnerability exists in spaceLYnk all versions before 2.4.0 and Wiser for KNX all versions before 2.4.0 - formerly known as homeLYnk, which could cause loss of control when an attacker bypasses the authentication...

8.3CVSS7AI score0.01461EPSS
SaveExploits0References1
CISA
CISA
added 2025/04/22 12:0 p.m.7 views

CISA Releases Five Industrial Control Systems Advisories

CISA released five Industrial Control Systems ICS advisories on April 22, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-112-01 Siemens TeleControl Server Basic SQL ICSA-25-112-02 Siemens TeleControl Server...

7AI score
SaveExploits0References5
RedhatCVE
RedhatCVE
added 2025/02/06 4:18 a.m.11 views

CVE-2021-22783

A CWE-200: Information Exposure vulnerability exists which could allow a session hijack when the door panel is communicating with the door. Affected Product: Ritto Wiser Door All versions...

8.8CVSS6.8AI score0.0037EPSS
SaveExploits0References1
NVD
NVD
added 2024/12/13 3:15 p.m.33 views

CVE-2023-41690

Missing Authorization vulnerability in Wiser Notify WiserNotify Social Proof allows Exploiting Incorrectly Configured Access Control Security Levels.This issue affects WiserNotify Social Proof: from n/a through 2.5...

5.3CVSS0.00461EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2024/07/11 12:0 a.m.7 views

Schneider Electric Wiser Home Controller WHC-5918A Information Disclosure Vulnerability

The Schneider Electric Wiser Home Controller WHC-5918A is a home controller from Schneider Electric France. The Schneider Electric Wiser Home Controller WHC-5918A is vulnerable to an information disclosure vulnerability that stems from the presence of an information disclosure vulnerability that...

9.8CVSS6.2AI score0.00426EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
added 2024/07/11 12:0 a.m.7 views

PT-2024-37601 · Schneider Electric · Wiser Home Controller Whc-5918A +1

Name of the Vulnerable Software and Affected Versions: No specific software or versions are mentioned in the provided descriptions. Description: An Information Exposure issue exists, potentially leading to the disclosure of credentials when a specially crafted message is sent to the device. This...

9.8CVSS5.8AI score0.00426EPSS
SaveExploits0References7
BDU FSTEC
BDU FSTEC
added 2023/04/20 12:0 a.m.9 views

The vulnerability of the microprogrammed software of Schneider Electric Ritto Wiser Door sensor, related to information disclosure during data exchange, allows a intruder to intercept the session.

The vulnerability of Schneider Electric Ritto Wiser Door door sensors’ microprogramming software is related to the disclosure of information during data exchange. Exploiting this vulnerability could allow a intruder to intercept a session...

8.3CVSS7.2AI score0.0037EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/03/29 12:0 a.m.20 views

Schneider Electric Wiser Smart Use of Hard-coded Credentials (CVE-2022-30234)

A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 V4.5 and prior This plugin only works with Tenable.ot. Please visit...

10CVSS8.6AI score0.01115EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2023/03/29 12:0 a.m.34 views

Schneider Electric Wiser Smart Improper Restriction of Excessive Authentication Attempts (CVE-2022-30235)

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow unauthorized access when an attacker uses brute force. Affected Products: Wiser Smart, EER21000 & EER21001 V4.5 and prior This plugin only works with Tenable.ot. Please visit...

9.8CVSS8.4AI score0.00948EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2023/03/29 12:0 a.m.24 views

Schneider Electric Wiser Smart Improper Input Validation (CVE-2022-30233)

A CWE-20: Improper Input Validation vulnerability exists that could allow the product to be maliciously manipulated when the user is tricked into performing certain actions on a webpage. Affected Products: Wiser Smart, EER21000 & EER21001 V4.5 and prior This plugin only works with Tenable.ot...

6.5CVSS6.5AI score0.00687EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2023/03/29 12:0 a.m.23 views

Schneider Electric Wiser Smart Missing Encryption of Sensitive Data (CVE-2022-30237)

A CWE-311: Missing Encryption of Sensitive Data vulnerability exists that could allow authentication credentials to be recovered when an attacker breaks the encoding. Affected Products: Wiser Smart, EER21000 & EER21001 V4.5 and prior This plugin only works with Tenable.ot. Please visit...

8.2CVSS7.3AI score0.00301EPSS
SaveExploits0References2
NVD
NVD
added 2023/01/30 11:15 p.m.18 views

CVE-2022-32513

A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC Versions prior to V1.10.0, Wiser for C-Bus Automation Controller -...

9.8CVSS9.7AI score0.00695EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2023/01/30 12:0 a.m.15 views

CVE-2022-32514

A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC Versions prior to V1.10.0, Wiser for C-Bus Automation Controller - LSS5500SHAC...

9.8CVSS9.7AI score0.00788EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2023/01/30 12:0 a.m.10 views

Schneider Electric C-Bus多款产品 授权问题漏洞

Schneider Electric C-Bus Home Automation is a series of bus-based home automation systems from French company Schneider Electric. An authorization issue vulnerability exists in various Schneider Electric C-Bus products, which stems from an improper authentication mechanism that allows an attacker...

9.8CVSS8.5AI score0.00788EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2023/01/30 12:0 a.m.26 views

CVE-2022-32513

A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC Versions prior to V1.10.0, Wiser for C-Bus Automation Controller -...

9.8CVSS9.8AI score0.00695EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2023/01/30 12:0 a.m.39 views

CVE-2022-32514

A CWE-287: Improper Authentication vulnerability exists that could allow an attacker to gain control of the device when logging into a web page. Affected Products: C-Bus Network Automation Controller - LSS5500NAC Versions prior to V1.10.0, Wiser for C-Bus Automation Controller - LSS5500SHAC...

9.8CVSS9.8AI score0.00788EPSS
SaveExploits0References1
Rows per page