Lucene search
K

34 matches found

EUVD
EUVD
added 2025/10/07 12:30 a.m.4 views

EUVD-2017-4261

Malware in sbrugna...

5.3CVSS6.7AI score0.00849EPSS
Exploits0References4
EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2017-4263

Malware in sbrugna...

8.1CVSS8.3AI score0.00459EPSS
Exploits0References3
EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2017-4265

Malware in sbrugna...

7.5CVSS7.6AI score0.00222EPSS
Exploits0References3
EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2017-4259

Malware in sbrugna...

8.1CVSS8.3AI score0.01234EPSS
Exploits0References3
EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2017-4260

Malware in sbrugna...

5.9CVSS6.4AI score0.00126EPSS
Exploits0References3
NVD
NVD
added 2018/02/15 10:29 a.m.16 views

CVE-2017-12721

An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...

5.9CVSS6.4AI score0.00126EPSS
Exploits0References2
Prion
Prion
added 2018/02/15 10:29 a.m.12 views

Input validation

An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...

4.3CVSS6.3AI score0.00126EPSS
Exploits0References2Affected Software1
Prion
Prion
added 2018/02/15 10:29 a.m.12 views

Hardcoded credentials

A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured ...

6.8CVSS8AI score0.00459EPSS
Exploits0References2Affected Software1
NVD
NVD
added 2018/02/15 10:29 a.m.10 views

CVE-2017-12725

A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establis...

6.8CVSS6.3AI score0.00178EPSS
Exploits0References2
NVD
NVD
added 2018/02/15 10:29 a.m.17 views

CVE-2017-12726

A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that i...

7.5CVSS7.6AI score0.00222EPSS
Exploits0References2
OSV
OSV
added 2018/02/15 10:29 a.m.2 views

CVE-2017-12722

An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the...

5.3CVSS5.8AI score0.00849EPSS
Exploits0References3
Prion
Prion
added 2018/02/15 10:29 a.m.13 views

Improper access control

An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections...

6.8CVSS8.1AI score0.01234EPSS
Exploits0References2Affected Software1
NVD
NVD
added 2018/02/15 10:29 a.m.16 views

CVE-2017-12718

A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on t...

8.1CVSS8.5AI score0.25769EPSS
Exploits3References4
NVD
NVD
added 2018/02/15 10:29 a.m.8 views

CVE-2017-12723

A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications...

4.3CVSS5.2AI score0.00175EPSS
Exploits0References2
OSV
OSV
added 2018/02/15 10:29 a.m.3 views

CVE-2017-12723

A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications...

3.7CVSS5.8AI score0.00175EPSS
Exploits0References2
NVD
NVD
added 2018/02/15 10:29 a.m.8 views

CVE-2017-12720

An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections...

8.1CVSS8.2AI score0.01234EPSS
Exploits0References2
NVD
NVD
added 2018/02/15 10:29 a.m.17 views

CVE-2017-12724

A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured ...

8.1CVSS8.1AI score0.00459EPSS
Exploits0References2
Prion
Prion
added 2018/02/15 10:29 a.m.11 views

Hardcoded credentials

A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establis...

6.8CVSS6.2AI score0.00178EPSS
Exploits0References2Affected Software1
CVE
CVE
added 2018/02/15 10:0 a.m.50 views

CVE-2017-12721

This CVE concerns the Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump and its failure to validate host certificates, enabling potential MITM attacks. Affected firmware versions are 1.1, 1.5, and 1.6. The underlying issue is Improper Certificate Validation, which can allow remote atta...

5.9CVSS5.6AI score0.00126EPSS
Exploits0References2Affected Software1
Cvelist
Cvelist
added 2018/02/15 10:0 a.m.17 views

CVE-2017-12724

A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured ...

8.1AI score0.00459EPSS
Exploits0References2