101 matches found
EUVD-2017-14270
Malware in sbrugna...
EUVD-2012-4302
Malware in sbrugna...
EUVD-2012-4301
Malware in sbrugna...
CVE-2011-4037
Buffer overflow in Sielco Sistemi Winlog PRO before 2.07.09 and Winlog Lite before 2.07.09 allows user-assisted remote attackers to execute arbitrary code via invalid data in unspecified fields of a project file...
CVE-2012-4356
Multiple directory traversal vulnerabilities in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allow remote attackers to read arbitrary files via port-46824 TCP packets specifying a file-open operation with opcode 0x78 and a .. dot dot in a pathname, followed ...
CVE-2012-4354
TCPIPSStory.dll in Sielco Sistemi Winlog Pro SCADA before 2.07.17 and Winlog Lite SCADA before 2.07.17 allows remote attackers to execute arbitrary code via a port-46824 TCP packet with a crafted positive integer after the opcode, triggering incorrect function-pointer processing that can lead to ...
Sielco Sistemi Winlog Remote File Access
This module requires Metasploit: https://metasploit.com/download Current source: https://github.com/rapid7/metasploit-framework class MetasploitModule 'Sielco Sistemi Winlog Remote File Access', 'Description' = %q This module exploits a directory traversal in Sielco Sistemi Winlog. The...
Sielco Sistemi Winlog 2.07.16 Buffer Overflow
require 'msf/core' class MetasploitModule 'Sielco Sistemi Winlog %q This module exploits a stack based buffer overflow found in Sielco Sistemi Winlog 'James Fitts' , 'License' = MSFLICENSE, 'Version' = '$Revision: $', 'References' = , 'Privileged' = true, 'DefaultOptions' = 'EXITFUNC' = 'thread',...
Sielco Sistemi Winlog 2.07.16 - Buffer Overflow Exploit
Exploit for windows platform in category remote exploits require 'msf/core' class MetasploitModule 'Sielco Sistemi Winlog %q This module exploits a stack based buffer overflow found in Sielco Sistemi Winlog 'James Fitts' , 'License' = MSFLICENSE, 'Version' = '$Revision: $', 'References' = ,...
Sielco Sistemi Winlog 2.07.16 - Remote Buffer Overflow (Metasploit)
require 'msf/core' class MetasploitModule 'Sielco Sistemi Winlog %q This module exploits a stack based buffer overflow found in Sielco Sistemi Winlog 'James Fitts' , 'License' = MSFLICENSE, 'Version' = '$Revision: $', 'References' = , 'Privileged' = true, 'DefaultOptions' = 'EXITFUNC' = 'thread',...
Sielco Sistemi Winlog 2.07.16 - Remote Buffer Overflow (Metasploit)
Sielco Sistemi Winlog 2.07.16 - Remote Buffer Overflow Metasploit require 'msf/core' class MetasploitModule 'Sielco Sistemi Winlog %q This module exploits a stack based buffer overflow found in Sielco Sistemi Winlog 'James Fitts' , 'License' = MSFLICENSE, 'Version' = '$Revision: $', 'References' ...
Sistemi Winlog SCADA Software DLL Hijacking
Sielco Sistemi Winlog SCADA Software Insecure Library Loading Allows Code Execution Vendor: Sielco Sistemi Equipment: Winlog SCADA Software Vulnerability: Uncontrolled Search Path Element ICS-CERT Advisory https://ics-cert.us-cert.gov/advisories/ICSA-17-038-01 AFFECTED PRODUCTS The following Siel...
CVE-2017-5161
An issue was discovered in Sielco Sistemi Winlog Lite SCADA Software, versions prior to Version 3.02.01, and Winlog Pro SCADA Software, versions prior to Version 3.02.01. An uncontrolled search path element DLL Hijacking vulnerability has been identified. Exploitation of this vulnerability could...
CVE-2017-5161
An issue was discovered in Sielco Sistemi Winlog Lite SCADA Software, versions prior to Version 3.02.01, and Winlog Pro SCADA Software, versions prior to Version 3.02.01. An uncontrolled search path element DLL Hijacking vulnerability has been identified. Exploitation of this vulnerability could...
CVE-2017-5161
CVE-2017-5161 concerns a DLL hijacking (Uncontrolled Search Path Element) vulnerability in Sielco Sistemi Winlog Lite/Pro SCADA software prior to 3.02.01. The root cause is an uncontrolled search path element that could allow a local attacker to load a malicious DLL and gain the same privileges a...
Sielco Sistemi Winlog Pro/ Winlog Lite DLL Load Local Code Execution Vulnerability
SIELCO SISTEMI Winlog is an application for data acquisition and remote control of SCADA HMI monitoring software. A local code execution vulnerability exists in Sielco Sistemi Winlog Pro and Winlog Lite. An attacker could exploit this vulnerability to execute arbitrary code in the affected...
ICSA-17-038-01_Sielco Sistemi Winlog SCADA Software
CVSS v3 7.2 Vendor: Sielco Sistemi Equipment: Winlog SCADA Software Vulnerability: Uncontrolled Search Path Element AFFECTED PRODUCTS The following Sielco Sistemi products are affected: Winlog Lite SCADA Software, versions prior to Version 3.02.01, and Winlog Pro SCADA Software, versions prior to...
Sielco Sistemi Winlog Buffer Overflow - Ver2 (CVE-2012-3815)
A stack-based buffer overflow vulnerability has been reported in Sielco Sistemi Winlog. The vulnerability is due to insufficient sanitation of TCP requests. A remote attacker can exploit this issue by sending a specially crafted TCP request to the affected server. Successful exploitation would...
sielco sistemi winlog 2.07.16 - Multiple Vulnerabilities
No description provided by source. Luigi Auriemma Application: Sielco Sistemi Winlog http://www.sielcosistemi.com/en/products/winlogscadahmi/ Versions: = 2.07.16 Platforms: Windows Bugs: A DbiGetRecordCount code execution B @Db@TDataSet@Close$qqrv code execution C DbiSetToRecordNo code execution ...
Sielco Sistemi Winlog <= 2.07.16 Buffer Overflow
No description provided by source. !/usr/bin/ruby Exploit Title: Sielco Sistemi Winlog Buffer Overflow = v2.07.16 Date: 05.06.2012 Exploit Author: m1k3 Vendor Homepage: http://www.sielcosistemi.com/en/download/public/winloglite.html Software Link:...