570 matches found
CVE-2008-2476
The IPv6 Neighbor Discovery Protocol NDP implementation in 1 FreeBSD 6.3 through 7.1, 2 OpenBSD 4.2 and 4.3, 3 NetBSD, 4 Force10 FTOS before E7.7.1.1, 5 Juniper JUNOS, and 6 Wind River VxWorks 5.x through 6.4 does not validate the origin of Neighbor Discovery messages, which allows remote attacke...
Multiple Cross-Site Scripting Vulnerabilities in Nordex NC2
Nordex Control 2 is a web-based SCADA system for wind power stations. Multiple cross-site scripting vulnerabilities exist in the Nordex Control 2 NC2 SCADA 16 and earlier versions, Wind Farm Portal application. A remote attacker can exploit this vulnerability to inject arbitrary web script or HTM...
Cross site scripting
Multiple cross-site scripting XSS vulnerabilities in the Wind Farm Portal application in Nordex Control 2 NC2 SCADA 16 and earlier allow remote attackers to inject arbitrary web script or HTML via unspecified vectors...
CVE-2015-6477
Multiple cross-site scripting XSS vulnerabilities in the Wind Farm Portal application in Nordex Control 2 NC2 SCADA 16 and earlier allow remote attackers to inject arbitrary web script or HTML via unspecified vectors...
CVE-2015-6477
Multiple cross-site scripting XSS vulnerabilities in the Wind Farm Portal application in Nordex Control 2 NC2 SCADA 16 and earlier allow remote attackers to inject arbitrary web script or HTML via unspecified vectors...
PT-2015-7264
Name of the Vulnerable Software and Affected Versions Nordex Control 2 NC2 SCADA versions 16 and earlier Description The issue concerns multiple cross-site scripting XSS vulnerabilities in the Wind Farm Portal application. These vulnerabilities allow remote attackers to inject arbitrary web scrip...
Wind River VxWorks Integer Overflow Vulnerability
VxWorks is a real-time operating system widely used on ICS-related devices. An integer overflow vulnerability exists in the implementation of Wind River VxWorks versions 5.5-6.9.4.1. Successful exploitation could allow an attacker to remotely execute arbitrary code in the operating system, corrup...
XZERES 442SR Wind Turbine Cross-site Scripting Vulnerability
OVERVIEW This updated advisory is a follow-up to the updated advisory titled ICSA-15-342-01B XZERES 442SR Wind Turbine Cross-site Scripting Vulnerability that was published March 21, 2016, on the NCCIC/ICS-CERT web site. --------- Begin Update C Part 1 of 2 -------- Independent researchers Karn...
CVE-2015-3963
Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnetcoreip 1.2.2.0, as used on Schneider Electric SAGE RTU devices before J2 and other devices, does not properly generate TCP initial sequence number ISN values, which...
Code injection
Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnetcoreip 1.2.2.0, as used on Schneider Electric SAGE RTU devices before J2 and other devices, does not properly generate TCP initial sequence number ISN values, which...
Nordex NC2 XSS Vulnerability
OVERVIEW Independent researcher Karn Ganeshen has identified a cross-site scripting vulnerability in Nordex’s NC2 Wind Farm Portal application. Nordex has produced an update to mitigate this vulnerability. This vulnerability could be exploited remotely. AFFECTED PRODUCTS The following Nordex NC2...
Wind River VxWorks TCP Predictability Vulnerability
According to its self-reported version, the Wind River VxWorks remote device is potentially affected by a TCP predictability vulnerability that allows a man-in-the-middle attacker to predict the TCP initial sequence numbers based on previous values. This can exploited to spoof or disrupt TCP...
TCP Vulnerability Haunts Wind River VxWorks Embedded OS
There is a TCP prediction vulnerability in Wind River’s widely deployed VxWorks embedded software that can enable an attacker to disrupt or spoof the TCP connections to and from target devices. VxWorks is an embedded operating system that’s used in a large number of ICS products that are deployed...
Wind River VXWorks TCP Predictable Vulnerability
VxWorks is a real-time operating system widely used on ICS-related devices. VxWorks software generates predictable initial TCP sequential numbers that can be predicted by an attacker based on previous values to spoof or interrupt TCP connections...
Wind River VXWorks TCP Predictability Vulnerability in ICS Devices (Update B)
OVERVIEW This updated advisory is a follow-up to the updated advisory titled ICSA-15-169-01A Wind River VxWorks TCP Predictability Vulnerability in ICS Devices that was published November 5, 2015, on the NCCIC/ICS-CERT web site. Raheem Beyah, David Formby, and San Shin Jung of Georgia Tech, via a...
Plaintext Credentials Threaten RLE Wind Turbine HMI
A week after disclosing a cross-site request forgery vulnerability in small wind turbines manufactured by a company called XZERES, a security researcher has discovered a serious bug in the human-machine interface for turbines made by German company RLE International GmbH. Researcher Maxim Rupp...
RLE Nova-Wind Turbine HMI Insecure Credentials Vulnerability
The Nova-Wind Turbine HMI is the human-machine interface for wind turbines. The Nova-Wind Turbine HMI stores credentials in plain document files, which can allow a malicious user to access the equipment, obtain sensitive information, and change the configuration...
CVE-2015-3951
RLE Nova-Wind Turbine HMI devices store cleartext credentials, which allows remote attackers to obtain sensitive information via unspecified vectors...