CVE-2011-4509

The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account...

10CVSS6.6AI score0.01975EPSS
SaveExploits0References2
NVD
NVD
•added 2012/02/03 8:55 p.m.•32 views

CVE-2011-4877

HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cau...

7.1CVSS6.5AI score0.07259EPSS
SaveExploits1References8
NVD
NVD
•added 2012/02/03 8:55 p.m.•39 views

CVE-2011-4876

Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is...

9.3CVSS6.7AI score0.09046EPSS
SaveExploits1References9
NVD
NVD
•added 2012/02/03 8:55 p.m.•30 views

CVE-2011-4513

Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file,...

10CVSS7.5AI score0.04776EPSS
SaveExploits0References2
NVD
NVD
•added 2012/02/03 8:55 p.m.•37 views

CVE-2011-4514

The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attacker...

10CVSS6.4AI score0.03377EPSS
SaveExploits0References2
Prion
Prion
•added 2012/02/03 8:55 p.m.•35 views

Cross site scripting

Cross-site scripting XSS vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime...

4.3CVSS5.9AI score0.0142EPSS
SaveExploits0References2Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•23 views

Default credentials

The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account...

10CVSS7.1AI score0.01975EPSS
SaveExploits0References2Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•33 views

Crlf injection

CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows...

5CVSS7.3AI score0.0161EPSS
SaveExploits0References2Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•30 views

Authentication flaw

The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attacker...

10CVSS7AI score0.03377EPSS
SaveExploits0References2Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•23 views

Cross site request forgery (csrf)

miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle UR...

8.5CVSS7.2AI score0.12105EPSS
SaveExploits1References8Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•32 views

Cross site scripting

Cross-site scripting XSS vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime...

4.3CVSS5.9AI score0.0142EPSS
SaveExploits0References2Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•27 views

Code injection

Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file,...

10CVSS8.1AI score0.04776EPSS
SaveExploits0References2Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•21 views

Authentication flaw

The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication token...

9.3CVSS7.2AI score0.02979EPSS
SaveExploits0References2Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•29 views

Directory traversal

Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 aka TIA portal before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexibl...

7.8CVSS7.1AI score0.11092EPSS
SaveExploits1References8Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•28 views

Directory traversal

Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is...

9.3CVSS7.2AI score0.09046EPSS
SaveExploits1References9Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•27 views

Code injection

HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cau...

7.1CVSS7.1AI score0.07259EPSS
SaveExploits1References8Affected Software3
Prion
Prion
•added 2012/02/03 8:55 p.m.•28 views

Stack overflow

Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled,...

9.3CVSS8.7AI score0.13841EPSS
SaveExploits1References8Affected Software3
CVE
CVE
•added 2012/02/03 8:00 p.m.•73 views

CVE-2011-4877

CVE-2011-4877 affects Siemens WinCC flexible products (2004–2008) and related SIMATIC HMI panels, WinCC V11 Runtime Advanced, and WinCC flexible Runtime. The issue lies in HmiLoad in the runtime loader; when Transfer Mode is enabled, sending crafted data over TCP can cause a remote denial of serv...

7.1CVSS6.7AI score0.07259EPSS
SaveExploits1References8Affected Software1
Cvelist
Cvelist
•added 2012/02/03 8:00 p.m.•50 views

CVE-2011-4509

The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 aka TIA portal; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account...

6.5AI score0.01975EPSS
SaveExploits0References2
CVE
CVE
•added 2012/02/03 8:00 p.m.•78 views

CVE-2011-4514

CVE-2011-4514 concerns the TELNET daemon in Siemens WinCC flexible (2004–2008) and WinCC V11 (TIA Portal), plus related SIMATIC HMI panels, which does not perform authentication, enabling remote access via TCP sessions. Affected products include WinCC flexible 2004/2005/2007/2008, WinCC V11, TP/O...