Lucene search
+L

5583 matches found

Cvelist
Cvelist
added 2019/07/02 8:33 p.m.31 views

CVE-2017-11578

It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the...

5.8AI score0.02049EPSS
SaveExploits1References3
CVE
CVE
added 2019/07/02 8:33 p.m.177 views

CVE-2017-11578

CVE-2017-11578 affects the Blipcare wireless blood pressure monitor. The device exposes its web management interface over plain HTTP (non-SSL), allowing an attacker on the same wireless network to conduct a MITM and sniff the user’s Wi‑Fi credentials. The impact is disclosure of credentials witho...

5.9CVSS5.7AI score0.02049EPSS
SaveExploits1References3Affected Software1
ThreatPost
ThreatPost
added 2019/06/21 9:13 p.m.215 views

MobOk Malware Hides in Photo Editors on Google Play, Siphons Cash

A powerful money-siphoning malware known as MobOk has been found hiding in seemingly legitimate photo editing apps available on the Google Play store. The Pink Camera and Pink Camera 2 apps, now removed, had been installed around 10,000 times, according to researchers at Kaspersky. They included...

0.7AI score
SaveExploits0References4
myhack58
myhack58
added 2019/06/21 12:00 a.m.326 views

TP-Link Wi-Fi extender remote code execution vulnerability analysis-vulnerability warning-the black bar safety net

WiFi extender can enlarge the WiFi signal, mainly used for large or multi-storey residential, and the router signal can not cover the family's case. The extender's principle is from the main router to get a WiFi signal, and broadcast channel other WiFi signal weak or no signal area. IBM X-Force...

0.4AI score
SaveExploits0
OSV
OSV
added 2019/06/20 2:15 p.m.22 views

CVE-2019-6962

A shell injection issue in cosawifiapis.c in the RDK RDKB-20181217-1 CcspWifiAgent module allows attackers with login credentials to execute arbitrary shell commands under the CcspWifiSsp process running as root if the platform was compiled with the ENABLEFEATUREMESHWIFI macro. The attack is...

7.5CVSS8.1AI score
SaveExploits0References1
Prion
Prion
added 2019/06/20 2:15 p.m.25 views

Sql injection

A shell injection issue in cosawifiapis.c in the RDK RDKB-20181217-1 CcspWifiAgent module allows attackers with login credentials to execute arbitrary shell commands under the CcspWifiSsp process running as root if the platform was compiled with the ENABLEFEATUREMESHWIFI macro. The attack is...

8.5CVSS8.1AI score0.01591EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2019/06/20 1:45 p.m.30 views

CVE-2019-6962

A shell injection issue in cosawifiapis.c in the RDK RDKB-20181217-1 CcspWifiAgent module allows attackers with login credentials to execute arbitrary shell commands under the CcspWifiSsp process running as root if the platform was compiled with the ENABLEFEATUREMESHWIFI macro. The attack is...

8.1AI score0.01591EPSS
SaveExploits0References1
CVE
CVE
added 2019/06/20 1:45 p.m.90 views

CVE-2019-6962

The CVE-2019-6962 issue affects the RDK B/CcspWifiAgent stack (RDKB-20181217-1) via the cosa_wifi_apis.c shell-injection path. If ENABLE_FEATURE_MESHWIFI is enabled, an attacker with login credentials can craft the Wi‑Fi network password to include escape characters, enabling arbitrary shell comm...

8.5CVSS8AI score0.01591EPSS
SaveExploits0References1Affected Software1
myhack58
myhack58
added 2019/06/19 12:00 a.m.114 views

TP-LINK Wi-Fi Repeater to a vulnerability that can be used for remote code execution-vulnerability warning-the black bar safety net

IBM X-Force researcher Grzegorz Wypych recently issued a warning that some of the TP-Link Wi-Fi Repeater devices there is a serious remote code execution vulnerability, the vulnerability can lead to external attackers access device privileges and execute arbitrary commands. ! IBM Security section...

2.8AI score
SaveExploits0
NVD
NVD
added 2019/06/17 10:15 p.m.38 views

CVE-2017-10720

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the desktop application used to connect to the device suffers from a stack overflow if more than 26 characters are passed to it as the Wi-Fi name. This application is installe...

7.8CVSS8AI score0.00735EPSS
SaveExploits1References3
NVD
NVD
added 2019/06/17 10:15 p.m.23 views

CVE-2017-10722

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the desktop application used to connect to the device suffers from a stack overflow if more than 26 characters are passed to it as the Wi-Fi password. This application is...

7.8CVSS8AI score0.00735EPSS
SaveExploits1References3
NVD
NVD
added 2019/06/17 10:15 p.m.22 views

CVE-2017-10724

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that an attacker connected to the device Wi-Fi SSID can exploit a memory corruption issue and execute remote code on the device. This device acts as an Endoscope camera that allows...

8.8CVSS9.2AI score0.02569EPSS
SaveExploits1References3
Prion
Prion
added 2019/06/17 10:15 p.m.17 views

Stack overflow

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the desktop application used to connect to the device suffers from a stack overflow if more than 26 characters are passed to it as the Wi-Fi password. This application is...

4.6CVSS8AI score0.00735EPSS
SaveExploits1References3
Prion
Prion
added 2019/06/17 10:15 p.m.16 views

Stack overflow

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the desktop application used to connect to the device suffers from a stack overflow if more than 26 characters are passed to it as the Wi-Fi name. This application is installe...

4.6CVSS8AI score0.00735EPSS
SaveExploits1References3
Prion
Prion
added 2019/06/17 10:15 p.m.20 views

Memory corruption

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that an attacker connected to the device Wi-Fi SSID can exploit a memory corruption issue and execute remote code on the device. This device acts as an Endoscope camera that allows...

6.5CVSS9.1AI score0.02569EPSS
SaveExploits1References3
Cvelist
Cvelist
added 2019/06/17 9:41 p.m.31 views

CVE-2017-10720

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the desktop application used to connect to the device suffers from a stack overflow if more than 26 characters are passed to it as the Wi-Fi name. This application is installe...

8AI score0.00735EPSS
SaveExploits1References3
CVE
CVE
added 2019/06/17 9:41 p.m.87 views

CVE-2017-10720

CVE-2017-10720 concerns the Shekar Endoscope desktop software. The issue is a stack overflow in the desktop application when more than 26 characters are provided for the Wi‑Fi name. The vulnerable code path involves the DLL avilib.dll and a function flow culminating in a memmove call that uses a ...

7.8CVSS8AI score0.00735EPSS
SaveExploits1References3Affected Software1
Cvelist
Cvelist
added 2019/06/17 9:39 p.m.33 views

CVE-2017-10722

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the desktop application used to connect to the device suffers from a stack overflow if more than 26 characters are passed to it as the Wi-Fi password. This application is...

8AI score0.00735EPSS
SaveExploits1References3
CVE
CVE
added 2019/06/17 9:39 p.m.74 views

CVE-2017-10722

CVE-2017-10722 concerns a stack overflow in the Shekar Endoscope’s desktop controller when a Wi‑Fi password longer than 26 characters is processed. The vulnerable path involves the avilib.dll routine that handles a change-password action via sendchangepass, with the input length contributing to a...

7.8CVSS8AI score0.00735EPSS
SaveExploits1References3Affected Software1
Cvelist
Cvelist
added 2019/06/17 9:36 p.m.26 views

CVE-2017-10724

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that an attacker connected to the device Wi-Fi SSID can exploit a memory corruption issue and execute remote code on the device. This device acts as an Endoscope camera that allows...

9.2AI score0.02569EPSS
SaveExploits1References3
Rows per page
Query Builder