38 matches found
EUVD-2026-33553
An uncontrolled allocation of resources without limits or throttling in the e-mail handling in OTRS allows excessive allocation which may lead to the abortion of the webserver.This issue affects OTRS: 8.0.X 2023.X 2024.X 2025.X 2026.X before 2026.4.X Please note that OTRS Community Edition 6.x,...
CVE-2025-10150
Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects smartLink HW-PN: from 1.02 through 1.03 smartLink HW-DP: 1.31...
CVE-2025-10150
Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects smartLink HW-PN: from 1.02 through 1.03 smartLink HW-DP: 1.31...
CVE-2025-10150 Webserver crash caused by scanning on TCP port 80
Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects smartLink HW-PN: from 1.02 through 1.03 smartLink HW-DP: 1.31...
CVE-2025-10150
CVE-2025-10150 refers to a webserver crash in Softing SmartLink gateways/switches triggered by scanning TCP port 80. Affected are SmartLink HW-PN versions 1.02–1.03 and HW-DP version 1.31. Connected advisories confirm the issue and provide remediation guidance: upgrade SmartLink HW-PN to a versio...
EUVD-2025-36438
Webserver crash caused by scanning on TCP port 80 in Softing Industrial Automation GmbH gateways and switch.This issue affects smartLink HW-PN: from 1.02 through 1.03 smartLink HW-DP: 1.31...
Siemens RUGGEDCOM ROS Devices Improper Handling of Exceptional Conditions (CVE-2025-41222)
Affected devices do not properly handle malformed TLS handshake messages. This could allow an attacker with network access to the webserver to cause a denial of service resulting in the web server and the device to crash. This plugin only works with Tenable.ot. Please visit...
EUVD-2019-13340
Malware in sbrugna...
EUVD-2021-21237
Malware in sbrugna...
EUVD-2021-22920
Malware in sbrugna...
EUVD-2021-23957
Malware in sbrugna...
EUVD-2022-27665
Malicious code in bioql PyPI...
CVE-2021-37388
A buffer overflow in D-Link DIR-615 C2 3.03WW. The pingipaddr parameter in pingresponse.cgi POST request allows an attacker to crash the webserver and might even gain remote code execution...
CVE-2019-14243
headerv2.go in mastercactapus proxyprotocol before 0.0.2, as used in the mastercactapus caddy-proxyprotocol plugin through 0.0.2 for Caddy, allows remote attackers to cause a denial of service webserver panic and daemon crash via a crafted HAProxy PROXY v2 request with truncated source/destinatio...
CVE-2021-34587
In Bender/ebee Charge Controllers in multiple versions a long URL could lead to webserver crash. The URL is used as input of an sprintf to a stack variable...
CVE-2021-34587
In Bender/ebee Charge Controllers in multiple versions a long URL could lead to webserver crash. The URL is used as input of an sprintf to a stack variable...
Stack overflow
In Bender/ebee Charge Controllers in multiple versions a long URL could lead to webserver crash. The URL is used as input of an sprintf to a stack variable...
CVE-2021-34587
Summary: CVE-2021-34587 affects Bender ebee Charge Controllers (CC612, CC613, ICC15xx/ICC16xx) with versions prior to 5.11.2, 5.12.5, 5.13.2, or 5.20.2. A long URL used as input to sprintf into a stack variable can crash the webserver. CNNVD notes this could allow bypassing credential checks and ...
CVE-2021-34587 Bender Charge Controller: Long URL could lead to webserver crash
In Bender/ebee Charge Controllers in multiple versions a long URL could lead to webserver crash. The URL is used as input of an sprintf to a stack variable...
CVE-2022-22519
A remote, unauthenticated attacker can send a specific crafted HTTP or HTTPS requests causing a buffer over-read resulting in a crash of the webserver of the CODESYS Control runtime system...