Multiple Websense Product 'explorer_wse' Path Access Bypass Vulnerabilities
Websense, Inc. NASDAQ: WBSN is the world's leading provider of integrated Web, information and data security protection solutions. Multiple Websense products are vulnerable to an "explorerwse" path access bypass vulnerability. This vulnerability allows attackers to bypass certain security...
CVE-2015-2748
Websense TRITON AP-WEB before 8.0.0 does not properly restrict access to files in explorerwse/, which allows remote attackers to obtain sensitive information via a direct request to a 1 Web Security incident report or the 2 Explorer configuration websense.ini file...
CVE-2015-2747
Multiple cross-site scripting XSS vulnerabilities in the data loss prevention DLP incident Forensics Preview in Websense Triton 7.8.3 and V-Series 7.7 appliances allow remote attackers to inject arbitrary web script or HTML via a crafted 1 email or 2 HTTP request, which triggers a DLP Policy...
CVE-2015-2746
The network diagnostics tool CommandLineServlet in the Appliance Manager command line utility CLU in Websense TRITON 7.8.3 and V-Series appliances before 7.8.4 Hotfix 02 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the "second" parameter of a command...
Information disclosure
Websense TRITON AP-WEB before 8.0.0 does not properly restrict access to files in explorerwse/, which allows remote attackers to obtain sensitive information via a direct request to a 1 Web Security incident report or the 2 Explorer configuration websense.ini file...
Command injection
The network diagnostics tool CommandLineServlet in the Appliance Manager command line utility CLU in Websense TRITON 7.8.3 and V-Series appliances before 7.8.4 Hotfix 02 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the "second" parameter of a command...
Cross site scripting
Multiple cross-site scripting XSS vulnerabilities in the data loss prevention DLP incident Forensics Preview in Websense Triton 7.8.3 and V-Series 7.7 appliances allow remote attackers to inject arbitrary web script or HTML via a crafted 1 email or 2 HTTP request, which triggers a DLP Policy...
CVE-2015-2748
CVE-2015-2748 affects Websense TRITON AP-WEB (and related Web Security/Explorer components) prior to version 8.0.0. The issue arises from failing to properly restrict access to the explorer_wse/ directory, allowing remote attackers to obtain sensitive information by directly requesting a Web Secu...
CVE-2015-2748
Websense TRITON AP-WEB before 8.0.0 does not properly restrict access to files in explorerwse/, which allows remote attackers to obtain sensitive information via a direct request to a 1 Web Security incident report or the 2 Explorer configuration websense.ini file...
CVE-2015-2746
The network diagnostics tool CommandLineServlet in the Appliance Manager command line utility CLU in Websense TRITON 7.8.3 and V-Series appliances before 7.8.4 Hotfix 02 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the "second" parameter of a command...
CVE-2015-2747
Multiple cross-site scripting XSS vulnerabilities in the data loss prevention DLP incident Forensics Preview in Websense Triton 7.8.3 and V-Series 7.7 appliances allow remote attackers to inject arbitrary web script or HTML via a crafted 1 email or 2 HTTP request, which triggers a DLP Policy...
CVE-2015-2747
CVE-2015-2747 corresponds to multiple XSS/HTML injection vulnerabilities in Websense TRITON/V-Series products. Public sources confirm affected components include the DLP/Forensics Preview in Websense Triton 7.8.3 and V-Series 7.7 (initial CVE description), with connected CNVD data indicating HTML...
Multiple Websense Product Cross-Site Scripting Vulnerabilities
Websense TRITON is the Unified Content Architecture for data security. A cross-site scripting vulnerability in Investigative Reports in multiple Websense TRITON products allows remote attackers to exploit the vulnerability to inject malicious script or HTML code, which can be used to gain access ...
Websense TRITON AP-EMAIL and V-Series Module Cross-Site Scripting Vulnerability
Websense TRITON AP-EMAIL and V-Series are both products of Websense, Inc. of the U.S.A. TRITON AP-EMAIL is an email security solution that identifies targeted attacks, high-risk users, and insider threats, while enabling mobile workers to take countermeasures and ensure their safe use of...
Websense TRITON AP-WEB and V-Series Module Cross-Site Scripting Vulnerability
Websense TRITON AP-WEB and V-Series are both products of Websense, Inc. The TRITON AP-WEB is available as a unified solution for local, remote, mobile, and cloud users through the V-Series, which is a V-Series module used in Websense applications. A cross-site scripting vulnerability exists in...
CVE-2015-2703
Multiple cross-site scripting XSS vulnerabilities in Websense TRITON AP-WEB before 8.0.0 and V-Series 7.7 appliances allow remote attackers to inject arbitrary web script or HTML via the 1 ws-userip in the ws-encdata parameter to cve-bin/moreBlockInfo.cgi in the Data Security block page or 2...
CVE-2015-2702
Cross-site scripting XSS vulnerability in the Message Log in the Email Security Gateway in Websense TRITON AP-EMAIL before 8.0.0 and V-Series 7.7 appliances allows remote attackers to inject arbitrary web script or HTML via the sender address in an email...
CVE-2014-9711
Multiple cross-site scripting XSS vulnerabilities in the Investigative Reports in Websense TRITON AP-WEB before 8.0.0 and Web Security and Filter, Web Security Gateway, and Web Security Gateway Anywhere 7.8.3 before Hotfix 02 and 7.8.4 before Hotfix 01 allow remote attackers to inject arbitrary w...
Cross site scripting
Multiple cross-site scripting XSS vulnerabilities in Websense TRITON AP-WEB before 8.0.0 and V-Series 7.7 appliances allow remote attackers to inject arbitrary web script or HTML via the 1 ws-userip in the ws-encdata parameter to cve-bin/moreBlockInfo.cgi in the Data Security block page or 2...
Cross site scripting
Cross-site scripting XSS vulnerability in the Message Log in the Email Security Gateway in Websense TRITON AP-EMAIL before 8.0.0 and V-Series 7.7 appliances allows remote attackers to inject arbitrary web script or HTML via the sender address in an email...