Lucene search
+L

4620 matches found

Vulnrichment
Vulnrichment
added 2026/02/06 6:32 a.m.10 views

CVE-2026-2000 DCN DCME-320 Web Management Backend bridge_cfg.php apply_config command injection

A vulnerability was found in DCN DCME-320 up to 20260121. Impacted is the function applyconfig of the file /function/system/basic/bridgecfg.php of the component Web Management Backend. Performing a manipulation of the argument iplist results in command injection. The attack is possible to be...

5.8CVSS5.3AI score0.17152EPSS
SaveExploits1References4
EUVD
EUVD
added 2026/02/06 6:32 a.m.12 views

EUVD-2026-5693

A vulnerability was found in DCN DCME-320 up to 20260121. Impacted is the function applyconfig of the file /function/system/basic/bridgecfg.php of the component Web Management Backend. Performing a manipulation of the argument iplist results in command injection. The attack is possible to be...

5.8CVSS5AI score0.17152EPSS
SaveExploits1References4
ATTACKERKB
ATTACKERKB
added 2026/02/06 6:32 a.m.8 views

CVE-2026-2000

A vulnerability was found in DCN DCME-320 up to 20260121. Impacted is the function applyconfig of the file /function/system/basic/bridgecfg.php of the component Web Management Backend. Performing a manipulation of the argument iplist results in command injection. The attack is possible to be...

5.8CVSS5.2AI score0.17152EPSS
SaveExploits1References4Affected Software1
CVE
CVE
added 2026/02/06 6:32 a.m.26 views

CVE-2026-2000

CVE-2026-2000 affects DCN DCME-320 Web Management Backend. The vulnerability is in apply_config() handling of the ip_list argument in /function/system/basic/bridge_cfg.php, where manipulation leads to command injection. It is remotely exploitable and exploits have been published. Public reports (...

7.2CVSS5AI score0.17152EPSS
SaveExploits1References4Affected Software1
Positive Technologies
Positive Technologies
added 2026/02/06 12:00 a.m.15 views

PT-2026-6684

Name of the Vulnerable Software and Affected Versions DCN DCME-320 versions up to 20260121 Description A flaw exists in the Web Management Backend component of DCN DCME-320. Specifically, manipulating the ip list argument within the apply config function of the /function/system/basic/bridge cfg.p...

5.8CVSS5.4AI score0.17152EPSS
SaveExploits1References7
Positive Technologies
Positive Technologies
added 2026/02/06 12:00 a.m.8 views

PT-2026-6775

Name of the Vulnerable Software and Affected Versions D-Link DIR-823X version 250416 Description A security flaw exists in the D-Link DIR-823X version 250416. The issue is located in the Web Management Interface, specifically within the file /goform/set ac server. Manipulation of the ac server...

5.8CVSS5.4AI score0.04413EPSS
SaveExploits1References8
CNNVD
CNNVD
added 2026/02/06 12:00 a.m.14 views

DCN DCME-320 命令注入漏洞

DCN DCME-320 is an Internet exchange gateway router developed by China's DCN Technology Co., Ltd. Versions of DCN DCME-320 prior to 20260121 contained a command injection vulnerability. This vulnerability stemmed from incorrect operations with the parameter iplist in the function applyconfig with...

7.2CVSS5.8AI score0.17152EPSS
SaveExploits1References4
RedhatCVE
RedhatCVE
added 2026/02/05 1:22 a.m.13 views

CVE-2026-1632

MOMA Seismic Station Version v2.4.2520 and prior exposes its web management interface without requiring authentication, which could allow an unauthenticated attacker to modify configuration settings, acquire device data or remotely reset the device...

9.3CVSS5.4AI score0.00474EPSS
SaveExploits0References1
NVD
NVD
added 2026/02/04 12:16 a.m.19 views

CVE-2026-1633

The Synectix LAN 232 TRIO 3-Port serial to ethernet adapter exposes its web management interface without requiring authentication, allowing unauthenticated users to modify critical device settings or factory reset the device...

10CVSS0.0055EPSS
SaveExploits0References2
CVE
CVE
added 2026/02/04 12:00 a.m.21 views

CVE-2025-70545

CVE-2025-70545 describes a stored XSS in the web management CGI of the Belden PPC ONT 2K05X router (firmware v1.1.9_206L). The vulnerability arises from improper handling of user input, enabling a remote, unauthenticated attacker to inject JavaScript that is persistently stored and executed when ...

6.1CVSS5.2AI score0.00306EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2026/02/04 12:00 a.m.42 views

CVE-2025-70545

A stored cross-site scripting XSS vulnerability exists in the web management interface of the PPC Belden ONT 2K05X router running firmware v1.1.9206L. The Common Gateway Interface CGI component improperly handles user-supplied input, allowing a remote, unauthenticated attacker to inject arbitrary...

0.00306EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2026/02/03 10:59 p.m.7 views

CVE-2026-1632 RISS SRL MOMA Seismic Station Missing Authentication for Critical Function

MOMA Seismic Station Version v2.4.2520 and prior exposes its web management interface without requiring authentication, which could allow an unauthenticated attacker to modify configuration settings, acquire device data or remotely reset the device...

9.3CVSS5.4AI score0.00474EPSS
SaveExploits0References2
CVE
CVE
added 2026/02/03 10:59 p.m.25 views

CVE-2026-1632

The CVE affects MOMA Seismic Station, specifically versions v2.4.2520 and prior, where the web management interface is exposed without authentication. The root cause is missing access control on the web UI, enabling an unauthenticated attacker to modify configuration settings, exfiltrate device d...

9.3CVSS5.4AI score0.00474EPSS
SaveExploits0References2
OSV
OSV
added 2026/02/03 7:16 p.m.9 views

CVE-2026-24426

Shenzhen Tenda AC7 firmware version V03.03.03.01cn and prior contain an improper output encoding vulnerability in the web management interface. User-supplied input is reflected in HTTP responses without adequate escaping, allowing injection of arbitrary HTML or JavaScript in a victim’s browser...

6.1CVSS5.9AI score0.00188EPSS
SaveExploits0References2
NVD
NVD
added 2026/02/03 7:16 p.m.13 views

CVE-2026-24427

Shenzhen Tenda AC7 firmware version V03.03.03.01cn and prior expose sensitive information in web management responses. Administrative credentials, including the router and/or admin panel password, are included in plaintext within configuration response bodies. In addition, responses lack...

6.8CVSS0.00118EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2026/02/03 7:13 p.m.7 views

CVE-2026-24434

Shenzhen Tenda AC7 firmware version V03.03.03.01cn and prior does not implement CSRF protections for administrative functions in the web management interface. The interface does not enforce anti-CSRF tokens or robust origin validation, which can allow an attacker to induce a logged-in administrat...

5.1CVSS5.5AI score0.00146EPSS
SaveExploits0References3
EUVD
EUVD
added 2026/02/03 7:13 p.m.10 views

EUVD-2026-5154

Shenzhen Tenda AC7 firmware version V03.03.03.01cn and prior does not implement CSRF protections for administrative functions in the web management interface. The interface does not enforce anti-CSRF tokens or robust origin validation, which can allow an attacker to induce a logged-in administrat...

5.1CVSS5.5AI score0.00146EPSS
SaveExploits0References2
EUVD
EUVD
added 2026/02/03 7:11 p.m.9 views

EUVD-2026-5184

Shenzhen Tenda AC7 firmware version V03.03.03.01cn and prior expose sensitive information in web management responses. Administrative credentials, including the router and/or admin panel password, are included in plaintext within configuration response bodies. In addition, responses lack...

6.8CVSS5.4AI score0.00118EPSS
SaveExploits0References2
ATTACKERKB
ATTACKERKB
added 2026/02/03 7:09 p.m.10 views

CVE-2026-24426

Shenzhen Tenda AC7 firmware version V03.03.03.01cn and prior contain an improper output encoding vulnerability in the web management interface. User-supplied input is reflected in HTTP responses without adequate escaping, allowing injection of arbitrary HTML or JavaScript in a victim’s browser...

5.1CVSS5.5AI score0.00188EPSS
SaveExploits0References3
CNNVD
CNNVD
added 2026/02/03 12:00 a.m.15 views

Tenda AC7 安全漏洞

The Tenda AC7 is a wireless router produced by the Chinese company Tenda. The Tenda AC7 V03.03.03.01cn and earlier versions have security vulnerabilities. These vulnerabilities stem from the exposure of sensitive information during web management responses, which may lead to credential leaks...

6.8CVSS5.8AI score0.00118EPSS
SaveExploits0References3
Rows per page
Query Builder