Lucene search
+L

17223 matches found

CVE
CVE
added 2025/08/26 4:26 p.m.20 views

CVE-2025-36729

The connected sources confirm CVE-2025-36729 concerns RACOM M!DGE2 devices where a non-primary administrator with web-interface rights (no shell access) can view device configuration, exposing the master admin password, and can escalate to shell access with root gid. The root cause is improper pe...

7.2CVSS6.5AI score0.00439EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2025/08/26 12:0 a.m.4 views

CVE-2025-50975

IPFire 2.29 web-based firewall interface firewall.cgi fails to sanitize several rule parameters such as PROT, SRCPORT, TGTPORT, dnatport, key, ruleremark, srcaddr, stdnettgt, and tgtaddr, allowing an authenticated administrator to inject persistent JavaScript. This stored XSS payload is executed...

5.4AI score0.00263EPSS
SaveExploits1References1
Positive Technologies
Positive Technologies
added 2025/08/26 12:0 a.m.13 views

PT-2025-34808 · Ipfire · Ipfire

Name of the Vulnerable Software and Affected Versions: IPFire version 2.29 Description: The web-based firewall interface firewall.cgi fails to sanitize several rule parameters, including PROT, SRC PORT, TGT PORT, dnatport, key, ruleremark, src addr, std net tgt, and tgt addr. This allows an...

5.4CVSS5.6AI score0.00263EPSS
SaveExploits1References5
Positive Technologies
Positive Technologies
added 2025/08/26 12:0 a.m.10 views

PT-2025-34793 · Ubiquiti · Ubiquiti Unifi

Name of the Vulnerable Software and Affected Versions: affected versions not specified Description: A non-primary administrator user with admin rights to the web interface, but without shell access permissions, can view the device configuration, including the master admin password. This also allo...

7.2CVSS7.1AI score0.00439EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2025/08/25 12:0 a.m.6 views

Linux Distros Unpatched Vulnerability : CVE-2017-7178

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - CSRF was discovered in the web UI in Deluge before 1.3.14. The exploitation methodology involves 1 hosting a crafted plugin that executes an arbitrary program...

8.8CVSS8.3AI score0.04018EPSS
SaveExploits2References2
Positive Technologies
Positive Technologies
added 2025/08/25 12:0 a.m.15 views

PT-2025-34744

Name of the Vulnerable Software and Affected Versions: egOS WebGUI affected versions not specified Description: The JWT secret key is embedded in the egOS WebGUI backend and is readable to the default user. An unauthenticated remote attacker can generate valid HS256 tokens and bypass...

9.8CVSS6.5AI score0.00522EPSS
SaveExploits0References13
RedhatCVE
RedhatCVE
added 2025/08/24 3:14 a.m.9 views

CVE-2025-41452

Post-authenticated external control of system web interface configuration setting vulnerability in Danfoss AK-SM8xxA Series prior to 4.3.1, which could allow for a denial of service attack induced by improper handling of exceptional conditions...

6.8CVSS7.2AI score0.00253EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/08/24 12:13 a.m.7 views

CVE-2022-43110

Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password,...

9.8CVSS7.7AI score0.0066EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/08/24 12:13 a.m.6 views

CVE-2022-31491

Voltronic Power ViewPower through 1.04-24215, ViewPower Pro through 2.0-22165, and PowerShield Netguard before 1.04-23292 allows a remote attacker to run arbitrary code via an unspecified web interface related to detection of a managed UPS shutting down. An unauthenticated attacker can use this t...

10CVSS8AI score0.00804EPSS
SaveExploits1References1
Tenable Nessus
Tenable Nessus
added 2025/08/24 12:0 a.m.8 views

Linux Distros Unpatched Vulnerability : CVE-2016-10026

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - ikiwiki 3.20161219 does not properly check if a revision changes the access permissions for a page on sites with the git and recentchanges plugins and the CGI...

7.5CVSS6.9AI score0.02129EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2025/08/24 12:0 a.m.3 views

Linux Distros Unpatched Vulnerability : CVE-2017-7557

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - dnsdist version 1.1.0 is vulnerable to a flaw in authentication mechanism for REST API potentially allowing CSRF attack. CVE-2017-7557 Note that Nessus relies o...

8.8CVSS7.9AI score0.00831EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2025/08/24 12:0 a.m.5 views

Linux Distros Unpatched Vulnerability : CVE-2014-4722

The Linux/Unix host has one or more packages installed that are impacted by a vulnerability without a vendor supplied patch available. - Multiple cross-site scripting XSS vulnerabilities in the OCS Reports Web Interface in OCS Inventory NG allow remote attackers to inject arbitrary web script or...

4.3CVSS5.4AI score0.02347EPSS
SaveExploits0References3
RedhatCVE
RedhatCVE
added 2025/08/23 8:13 p.m.11 views

CVE-2010-20113

EasyFTP Server 1.7.0.11 and earlier contains a stack-based buffer overflow vulnerability in its HTTP interface. When processing a GET request to list.html, the server fails to properly validate the length of the path parameter. Supplying an excessively long value causes a buffer overflow on the...

9.8CVSS7.9AI score0.01555EPSS
SaveExploits1References1
NVD
NVD
added 2025/08/22 8:15 p.m.8 views

CVE-2022-31491

Voltronic Power ViewPower through 1.04-24215, ViewPower Pro through 2.0-22165, and PowerShield Netguard before 1.04-23292 allows a remote attacker to run arbitrary code via an unspecified web interface related to detection of a managed UPS shutting down. An unauthenticated attacker can use this t...

10CVSS0.00804EPSS
SaveExploits1References2
RedhatCVE
RedhatCVE
added 2025/08/22 4:35 p.m.10 views

CVE-2010-20059

FreeNAS 0.7.2 prior to revision 5543 includes an unauthenticated command‐execution backdoor in its web interface. The execraw.php script exposes a cmd parameter that is passed directly to the underlying shell without sanitation...

9.3CVSS7.2AI score0.01022EPSS
SaveExploits1References1
RedhatCVE
RedhatCVE
added 2025/08/22 4:35 p.m.9 views

CVE-2025-20269

A vulnerability in the web-based management interface of Cisco Evolved Programmable Network Manager EPNM and Cisco Prime Infrastructure could allow an authenticated, low-privileged, remote attacker to retrieve arbitrary files from the underlying file system on an affected device. This vulnerabili...

6.5CVSS7.3AI score0.00413EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
added 2025/08/22 7:36 a.m.9 views

CVE-2025-9225

Stored cross-site scripting XSS in the web interface of MiR software versions prior to 3.0.0 on MiR Robots and MiR Fleet allows execution of arbitrary JavaScript code in a victim’s browser...

5.5CVSS6.1AI score0.00258EPSS
SaveExploits0References1
CVE
CVE
added 2025/08/22 2:40 a.m.26 views

CVE-2025-41452

Danfoss AK-SM8xxA Series before 4.3.1 contains a post-authenticated external control of the system Web interface configuration, with improper handling of exceptional conditions that could cause a DoS. CVSS 6.8 (Network, high attack complexity, high impact on availability). Remediation: update to ...

6.8CVSS7.2AI score0.00253EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2025/08/22 2:40 a.m.16 views

CVE-2025-41452 Post auth nginx configuration injection in Danfoss AK-SM8xxA Series

Post-authenticated external control of system web interface configuration setting vulnerability in Danfoss AK-SM8xxA Series prior to 4.3.1, which could allow for a denial of service attack induced by improper handling of exceptional conditions...

6.8CVSS0.00253EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
added 2025/08/22 12:0 a.m.4 views

CVE-2022-31491

Voltronic Power ViewPower through 1.04-24215, ViewPower Pro through 2.0-22165, and PowerShield Netguard before 1.04-23292 allows a remote attacker to run arbitrary code via an unspecified web interface related to detection of a managed UPS shutting down. An unauthenticated attacker can use this t...

7.9AI score0.00804EPSS
SaveExploits1References2
Rows per page
Query Builder