Lucene search
K

9 matches found

EUVD
EUVD
added 2025/10/07 12:30 a.m.2 views

EUVD-2014-2415

Malware in sbrugna...

7.6CVSS6.4AI score0.00189EPSS
Exploits0References2
NVD
NVD
added 2014/09/05 5:55 p.m.8 views

CVE-2014-2378

Sensys Networks VSN240-F and VSN240-T sensors VDS before 2.10.1 and TrafficDOT before 2.10.3 do not verify the integrity of downloaded updates, which allows remote attackers to execute arbitrary code via a Trojan horse update...

7.6CVSS7.7AI score0.00189EPSS
Exploits0References4
NVD
NVD
added 2014/09/05 5:55 p.m.11 views

CVE-2014-2379

Sensys Networks VSN240-F and VSN240-T sensors VDS before 2.10.1 and TrafficDOT before 2.10.3 do not use encryption, which allows remote attackers to interfere with traffic control by replaying transmissions on a wireless network...

5.4CVSS6.7AI score0.00046EPSS
Exploits0References4
Prion
Prion
added 2014/09/05 5:55 p.m.12 views

Code injection

Sensys Networks VSN240-F and VSN240-T sensors VDS before 2.10.1 and TrafficDOT before 2.10.3 do not use encryption, which allows remote attackers to interfere with traffic control by replaying transmissions on a wireless network...

5.4CVSS7.2AI score0.00046EPSS
Exploits0References1Affected Software2
Prion
Prion
added 2014/09/05 5:55 p.m.15 views

Code injection

Sensys Networks VSN240-F and VSN240-T sensors VDS before 2.10.1 and TrafficDOT before 2.10.3 do not verify the integrity of downloaded updates, which allows remote attackers to execute arbitrary code via a Trojan horse update...

7.6CVSS8.2AI score0.00189EPSS
Exploits0References1Affected Software2
Cvelist
Cvelist
added 2014/09/05 5:0 p.m.15 views

CVE-2014-2379 Sensys Networks Traffic Sensor Missing Encryption of Sensitive Data

Sensys Networks VSN240-F and VSN240-T sensors VDS before 2.10.1 and TrafficDOT before 2.10.3 do not use encryption, which allows remote attackers to interfere with traffic control by replaying transmissions on a wireless network...

4.3CVSS6.7AI score0.00046EPSS
Exploits0References3
Cvelist
Cvelist
added 2014/09/05 5:0 p.m.13 views

CVE-2014-2378 Sensys Networks Traffic Sensor Download of Code Without Integrity Check

Sensys Networks VSN240-F and VSN240-T sensors VDS before 2.10.1 and TrafficDOT before 2.10.3 do not verify the integrity of downloaded updates, which allows remote attackers to execute arbitrary code via a Trojan horse update...

6.5CVSS7.7AI score0.00189EPSS
Exploits0References3
CVE
CVE
added 2014/09/05 5:0 p.m.49 views

CVE-2014-2379

CVE-2014-2379 affects Sensys Networks VSN240-F/VSN240-T sensors and TrafficDOTs prior to the fixed versions. The root cause is missing encryption for wireless communications, enabling an attacker in an adjacent network to replay transmissions and potentially influence traffic data or sensor integ...

5.4CVSS6.9AI score0.00046EPSS
Exploits0References4Affected Software3
CVE
CVE
added 2014/09/05 5:0 p.m.44 views

CVE-2014-2378

The CVE-2014-2378 vulnerability affects Sensys Networks VSN240-F and VSN240-T traffic sensors (VDS before 2.10.1 and TrafficDOT before 2.10.3). The root cause is failure to verify the integrity of downloaded updates, allowing a Trojan horse update to execute arbitrary code on the device after del...

7.6CVSS7.9AI score0.00189EPSS
Exploits0References4Affected Software3
Rows per page
Query Builder