350 matches found
Schneider Electric Modicon M221 Programmable Logic Controller Use of a One-Way Hash with a Predictable Salt (CVE-2020-28214)
A CWE-760: Use of a One-Way Hash with a Predictable Salt vulnerability exists in Modicon M221 all references, all versions, that could allow an attacker to pre-compute the hash value using dictionary attack technique such as rainbow tables, effectively disabling the protection that an unpredictab...
Schneider Electric Modicon M221 Programmable Logic Controller Missing Encryption of Sensitive Data (CVE-2020-7567)
A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Modicon M221 all references, all versions that could allow the attacker to find the password hash when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller and broke t...
Sub-IoT DASH 7 Alliance Protocol stack implementation
1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Sub-IoT project Equipment: DASH 7 Alliance Protocol stack implementation Vulnerability: Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to...
North Korean Hackers Targeting Healthcare with Ransomware to Fund its Operations
State-backed hackers from North Korea are conducting ransomware attacks against healthcare and critical infrastructure facilities to fund illicit activities, U.S. and South Korean cybersecurity and intelligence agencies warned in a joint advisory. The attacks, which demand cryptocurrency ransoms ...
The rise of multi-threat ransomware
Today we have a ten minute YouTube expedition into the murky world of ransomware. In the video, "The rise of multi-threat ransomware" embedded below, I cover a couple of key talking points that always seem to come up in conversation. Single, double, triple? The video covers how ransomware made th...
Delta Electronics DVW-W02W2-E2
1. EXECUTIVE SUMMARY CVSS v3 9.9 ATTENTION: Public exploit available/exploitable remotely/low attack complexity Vendor: Delta Electronics Equipment: DVW-W02W2-E2 Vulnerabilities: OS Command Injection 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a threat actor with...
Delta Electronics CNCSoft ScreenEditor
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Delta Electronics Equipment: CNCSoft Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a buffer overflow condition, which could allow remote code...
SOCOMEC MODULYS GP (UPDATE A)
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.7 ATTENTION : Exploitable remotely/low attack complexity Vendor : SOCOMEC Equipment : MODULYS GP Vulnerability : Weak Encoding for Password 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to obtain sensitive...
Beware: Tainted VPNs Being Used to Spread EyeSpy Surveillanceware
Tainted VPN installers are being used to deliver a piece of surveillanceware dubbed EyeSpy as part of a malware campaign that started in May 2022. It uses "components of SecondEye – a legitimate monitoring application – to spy on users of 20Speed VPN, an Iranian-based VPN service, via trojanized...
Omron CX-Programmer
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Omron Equipment: CX-Programmer Vulnerability: Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of this vulnerability could allow arbitrary code execution or loss of sensitive information if a user opens a...
Rockwell Automation Studio 5000 Logix Emulate
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Rockwell Automation Equipment: Studio 5000 Logix Emulate Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a malicious user to perform remote code execution,...
Priva TopControl Suite
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Priva Equipment: TopControl Suite Vulnerability: Use of Password Hash with Insufficient Computational Effort 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to...
Delta 4G Router DX-3021
1. EXECUTIVE SUMMARY CVSS v3 7.2 ATTENTION: Exploitable remotely/low attack complexity Vendor : Delta Industrial Automation Equipment: 4G Router DX-3021 Vulnerabilities: Command Injection 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a remote unauthenticated user to...
Rockwell Automation MicroLogix 1100 and 1400
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: MicroLogix 1100 and 1400 Vulnerabilities: Cross-site Scripting, Improper Restriction of Rendered UI Layers or Frames 2. RISK EVALUATION Successful exploitation of these...
Siemens SIMATIC S7-1500 CPU GNU/Linux subsystem (Update A)
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
Siemens APOGEE/TALON Field Panels
1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: APOGEE PXC/TALON TC Vulnerabilities: Predictable Exact Value from Previous Values 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to hijack...
Siemens Polarion ALM
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please seeSiemens' ProductCERT Security Advisories CERT Services | Services |...
Siemens APOGEE and TALON
1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: APOGEE and TALON Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a low privilege authenticated attacker to gain...
Siemens Mendix Email Connector
1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Mendix Email Connector Vulnerability: Improper Access Control 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an authenticated remote attacker to read and...
Siemens Mendix Workflow Commons
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...