Lucene search
+L

568 matches found

Positive Technologies
Positive Technologies
added 2022/05/11 12:00 a.m.7 views

PT-2022-9746 · Suse · Suse

Name of the Vulnerable Software and Affected Versions: No specific software or versions are mentioned in the provided descriptions. Description: The issue is related to insufficient bound checks in the System Management Unit SMU, which may cause a system voltage malfunction. This could potentiall...

8.8CVSS5.2AI score0.00491EPSS
SaveExploits0References57
CNNVD
CNNVD
added 2022/05/11 12:00 a.m.10 views

AMD System Management Unit 输入验证错误漏洞

The AMD System Management Unit SMU is a system management unit at UltraMicroelectronics AMD. The AMD System Management Unit suffers from an input validation error vulnerability that originates from an insufficient boundary check in the System Management Unit SMU, which can lead to a system voltag...

5.5CVSS5.6AI score0.00212EPSS
SaveExploits0References6
ATTACKERKB
ATTACKERKB
added 2022/05/10 8:00 p.m.5 views

CVE-2021-26373

Insufficient bound checks in the System Management Unit SMU may result in a system voltage malfunction that could result in denial of resources and/or possibly denial of service...

5.5CVSS5.6AI score0.00212EPSS
SaveExploits0References3
OSV
OSV
added 2022/04/12 9:15 a.m.8 views

CVE-2022-25755

A vulnerability has been identified in SCALANCE X302-7 EEC 230V, SCALANCE X302-7 EEC 230V, coated, SCALANCE X302-7 EEC 24V, SCALANCE X302-7 EEC 24V, coated, SCALANCE X302-7 EEC 2x 230V, SCALANCE X302-7 EEC 2x 230V, coated, SCALANCE X302-7 EEC 2x 24V, SCALANCE X302-7 EEC 2x 24V, coated, SCALANCE...

7.5CVSS5.8AI score0.01329EPSS
SaveExploits0References1
zdt
zdt
added 2022/02/05 12:00 a.m.361 views

Voltage SecureMail Server Business Logic Bypass Vulnerability

======================================================================= title: Business Logic Bypass - Mail Relay Post-authenticated product: Voltage SecureMail Server vulnerable version: Voltage SecureMail Server v7.3.0.1 fixed version: Voltage SecureMail Server v7.3.0.1 CVE number: CVE-2021-381...

6.5CVSS0.3AI score0.00857EPSS
SaveExploits2
NVD
NVD
added 2022/02/04 11:15 p.m.54 views

CVE-2021-38130

A potential Information leakage vulnerability has been identified in versions of Micro Focus Voltage SecureMail Mail Relay prior to 7.3.0.1. The vulnerability could be exploited to create an information leakage attack...

6.5CVSS0.00857EPSS
SaveExploits2References1
OSV
OSV
added 2022/02/04 11:15 p.m.8 views

CVE-2021-38130

A potential Information leakage vulnerability has been identified in versions of Micro Focus Voltage SecureMail Mail Relay prior to 7.3.0.1. The vulnerability could be exploited to create an information leakage attack...

6.5CVSS5.7AI score0.00857EPSS
SaveExploits2References1
Cvelist
Cvelist
added 2022/02/04 10:29 p.m.45 views

CVE-2021-38130

A potential Information leakage vulnerability has been identified in versions of Micro Focus Voltage SecureMail Mail Relay prior to 7.3.0.1. The vulnerability could be exploited to create an information leakage attack...

6.5AI score0.00857EPSS
SaveExploits2References1
Packet Storm
Packet Storm
added 2022/02/04 12:00 a.m.308 views

Voltage SecureMail Server Business Logic Bypass

Security Advisory ======================================================================= title: Business Logic Bypass - Mail Relay Post-authenticated product: Voltage SecureMail Server vulnerable version: Voltage SecureMail Server v7.3.0.1 fixed version: Voltage SecureMail Server v7.3.0.1 CVE...

0.2AI score0.00857EPSS
SaveExploits2
CNNVD
CNNVD
added 2022/02/04 12:00 a.m.13 views

Micro Focus Voltage SecureMail Server 安全漏洞

Micro Focus Voltage SecureMail Server is a Saas-secure email encryption solution from Micro Focus UK. A security vulnerability exists in Micro Focus Voltage SecureMail Mail Relay versions prior to 7.3.0.1, which stems from a lack of protection for sensitive information in the software. The...

6.5CVSS6.5AI score0.00857EPSS
SaveExploits2References3
Positive Technologies
Positive Technologies
added 2022/02/03 12:00 a.m.12 views

PT-2022-10694 · Micro Focus · Micro Focus Voltage Securemail Mail Relay +1

Name of the Vulnerable Software and Affected Versions: Micro Focus Voltage SecureMail Mail Relay versions prior to 7.3.0.1 Description: A potential information leakage issue has been identified. This could be exploited to create an information leakage attack. The issue is related to a business...

6.5CVSS6.2AI score0.00857EPSS
SaveExploits2References3
CNVD
CNVD
added 2022/01/16 12:00 a.m.52 views

Schneider Electric Easergy P5 Buffer Overflow Vulnerability

The Schneider Electric Easergy P5 is a protective relay for demanding medium voltage applications from Schneider Electric, France. The Schneider Electric Easergy P5 is vulnerable to a buffer overflow vulnerability that exists due to a boundary error when handling untrusted input. An attacker coul...

8.8CVSS9.1AI score0.02822EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/01/16 12:00 a.m.58 views

Schneider Electric Easergy P5 Trust Management Issue Vulnerability

The Schneider Electric Easergy P5 is a protective relay for demanding medium voltage applications from Schneider Electric, France. The Schneider Electric Easergy P5 is vulnerable to a trust management issue, which exists due to the presence of hard-coded credentials in the application code. An...

7.5CVSS7.6AI score0.02371EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2021/12/02 8:15 p.m.5 views

CVE-2021-43327

An issue was discovered on Renesas RX65 and RX65N devices. With a VCC glitch, an attacker can extract the security ID key from the device. Then, the protected firmware can be extracted...

4.6CVSS5.8AI score0.00329EPSS
SaveExploits1References2
CNVD
CNVD
added 2021/08/05 12:00 a.m.63 views

Unspecified Vulnerability in Siemens Interniche IP Stack Low Voltage Devices

The SENTRON 3WA COM190 is an accessory module for 3WA circuit breakers providing connectivity via PROFINET IO and Modbus TCP.The SENTRON 3WL COM35 is an accessory module for 3WL circuit breakers providing connectivity via PROFINET IO and Modbus TCP.The SENTRON 7KM PAC The Switched Ethernet PROFIN...

9.1CVSS9.2AI score0.02051EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2021/08/04 12:00 a.m.13 views

HCC Embedded InterNiche 安全特征问题漏洞

The SENTRON 3WA COM190 is an accessory module for 3WA circuit breakers providing connectivity via PROFINET IO and Modbus TCP.The SENTRON 3WL COM35 is an accessory module for 3WL circuit breakers providing connectivity via PROFINET IO and Modbus TCP.The SENTRON 7KM PAC The Switched Ethernet PROFIN...

9.1CVSS5.5AI score0.02051EPSS
SaveExploits0References8
NVD
NVD
added 2021/07/22 5:15 p.m.27 views

CVE-2021-33478

The TrustZone implementation in certain Broadcom MediaxChange firmware could allow an unauthenticated, physically proximate attacker to achieve arbitrary code execution in the TrustZone Trusted Execution Environment TEE of an affected device. This, for example, affects certain Cisco IP Phone and...

6.8CVSS0.00304EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2021/07/22 4:53 p.m.34 views

CVE-2021-33478

The TrustZone implementation in certain Broadcom MediaxChange firmware could allow an unauthenticated, physically proximate attacker to achieve arbitrary code execution in the TrustZone Trusted Execution Environment TEE of an affected device. This, for example, affects certain Cisco IP Phone and...

7.2AI score0.00304EPSS
SaveExploits0References1
NVD
NVD
added 2021/06/28 1:15 p.m.29 views

CVE-2021-31337

The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products SINAMICS SL15...

9.8CVSS0.01678EPSS
SaveExploits0References1
Prion
Prion
added 2021/06/28 1:15 p.m.28 views

Authentication flaw

The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products SINAMICS SL15...

6.8CVSS9.4AI score0.01678EPSS
SaveExploits0References1
Rows per page
Query Builder