335 matches found
CVE-2025-66050 No password set for administrative account in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions...
CVE-2025-66050
CVE-2025-66050 (Vivotek IP7137, firmware 0200a) is linked to multiple issues: path traversal (CVE-2025-66051), information disclosure via RTSP without authentication (CVE-2025-66049), and command injection through /cgi-bin/admin/setparam.cgi (CVE-2025-66052). All references indicate default admin...
CVE-2025-66050 No password set for administrative account in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions...
CVE-2025-66049 Unprotected RTSP stream in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed,...
CVE-2025-66049 Unprotected RTSP stream in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed,...
CVE-2025-66049
Affected product: Vivotek IP7137 camera with firmware 0200a. Vulnerabilities: (1) information disclosure via RTSP on port 8554 without authentication, exposing live feed; (2) command injection via /cgi-bin/admin/setparam.cgi with parameter system_ntpIt, exploitable by an admin user; (3) path trav...
Vivotek IP7137 访问控制错误漏洞
The Vivotek IP7137 is an IP camera from China's VIVOTEK Communications Vivotek. An access control error vulnerability exists in the Vivotek IP7137 version 0200a, which originates from accessing the live camera feed via the RTSP protocol without authentication, which could lead to information...
Vivotek IP7137 安全漏洞
Vivotek IP7137 is an IP camera from China VIVOTEK Communications Vivotek. A security vulnerability exists in the Vivotek IP7137 version 0200a, which stems from the default situation where no password is required when logging in as administrator, which could lead to unauthorized access...
PT-2026-1856
Name of the Vulnerable Software and Affected Versions Vivotek IP7137 camera versions prior to 0200a Description The Vivotek IP7137 camera is affected by a command injection issue. The /cgi-bin/admin/setparam.cgi API endpoint does not properly sanitize the system ntpIt parameter. This allows a use...
Vivotek IP7137 操作系统命令注入漏洞
The Vivotek IP7137 is an IP camera from China's Vivotek Communications Vivotek. An operating system command injection vulnerability exists in the Vivotek IP7137 version 0200a, which stems from improper cleanup of the parameter systemntpIt, and could lead to a command injection attack...
PT-2026-1855
Name of the Vulnerable Software and Affected Versions Vivotek IP7137 camera versions prior to firmware version 0200a Description The Vivotek IP7137 camera is susceptible to a path traversal issue. An authenticated attacker can potentially access resources outside the intended webroot directory by...
PT-2026-1854
Name of the Vulnerable Software and Affected Versions Vivotek IP7137 camera versions prior to firmware version 0200a Description The Vivotek IP7137 camera, with firmware version 0200a, does not require a password by default when logging in as an administrator. Although setting a password is...
Vivotek IP7137 路径遍历漏洞
The Vivotek IP7137 is an IP camera from China's Vivotek Communications Vivotek. A path traversal vulnerability exists in the Vivotek IP7137 version 0200a, which can be exploited by an authenticated attacker to access resources outside of the web root directory via a direct HTTP request, potential...
PT-2026-1853
Name of the Vulnerable Software and Affected Versions Vivotek IP7137 camera versions prior to 0200a Description The Vivotek IP7137 camera is affected by an information disclosure issue. Live camera footage can be accessed through the Real Time Streaming Protocol RTSP on port 8554 without...
Exploit for CVE-2019-19936
This exploit is based off of this blog post by Larry Cashdollar...
CVE-2025-12592
Legacy Vivotek Device firmware uses default credetials for the root and user login accounts...
Firmwhere? Rediscovering a Vulnerability in Vivotek Legacy Firmware
...
EUVD-2025-198160
Legacy Vivotek Device firmware uses default credetials for the root and user login accounts...
CVE-2025-12592
Legacy Vivotek Device firmware uses default credetials for the root and user login accounts...
CVE-2025-12592
Consolidated data confirms CVE-2025-12592 affects legacy Vivotek device firmware, where default credentials for root and user logins grant unauthorized access. The vulnerability is characterized by high-impact metrics (confidentiality, integrity, availability all High) with network-exploitability...