Lucene search
+L

404 matches found

osv_cve
osv_cve
•added 2026/01/09 12:15 p.m.•16 views

CVE-2025-66049

Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed,...

7.5CVSS7AI score0.00411EPSS
SaveExploits0References1
osv_cve
osv_cve
•added 2026/01/09 12:15 p.m.•25 views

CVE-2025-66051

Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor ha...

6.5CVSS6AI score0.00826EPSS
SaveExploits0References1
osv_cve
osv_cve
•added 2026/01/09 12:15 p.m.•24 views

CVE-2025-66052

Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "systemntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access...

7.2CVSS7AI score0.01491EPSS
SaveExploits0References1
NVD
NVD
•added 2026/01/09 12:15 p.m.•24 views

CVE-2025-66051

Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor ha...

6.9CVSS0.00826EPSS
SaveExploits0References1
NVD
NVD
•added 2026/01/09 12:15 p.m.•30 views

CVE-2025-66049

Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed,...

8.7CVSS0.00411EPSS
SaveExploits0References1
NVD
NVD
•added 2026/01/09 12:15 p.m.•28 views

CVE-2025-66050

Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions...

9.8CVSS0.00392EPSS
SaveExploits0References1
NVD
NVD
•added 2026/01/09 12:15 p.m.•25 views

CVE-2025-66052

Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "systemntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access...

8.6CVSS0.01491EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2026/01/09 11:54 a.m.•11 views

CVE-2025-66052 Command injection in Vivotek IP7137 cameras

Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "systemntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access...

8.6CVSS7AI score0.01491EPSS
SaveExploits0References1
CVE
CVE
•added 2026/01/09 11:54 a.m.•55 views

CVE-2025-66052

The CVE-2025-66052 entry concerns the Vivotek IP7137 camera with firmware 0200a. The vulnerability is a command injection in /cgi-bin/admin/setparam.cgi via the non-sanitized system_ntpIt parameter, exploitable by a user with administrative privileges. The issue is compounded by CVE-2025-66050, w...

8.6CVSS7AI score0.01491EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2026/01/09 11:54 a.m.•55 views

CVE-2025-66052 Command injection in Vivotek IP7137 cameras

Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "systemntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access...

8.6CVSS0.01491EPSS
SaveExploits0References1
CVE
CVE
•added 2026/01/09 11:54 a.m.•40 views

CVE-2025-66051

CVE-2025-66051 affects the Vivotek IP7137 camera running firmware 0200a. A path traversal flaw allows an authenticated attacker to access resources outside the webroot via a direct HTTP request. The issue is linked to end-of-life status of the product and there is no expected fix. The vulnerabili...

6.9CVSS5.3AI score0.00826EPSS
SaveExploits0References1Affected Software1
Vulnrichment
Vulnrichment
•added 2026/01/09 11:54 a.m.•13 views

CVE-2025-66051 Path traversal in Vivotek IP7137 cameras

Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor ha...

6.9CVSS5.3AI score0.00826EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2026/01/09 11:54 a.m.•51 views

CVE-2025-66051 Path traversal in Vivotek IP7137 cameras

Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. Due to CVE-2025-66050, a password for administration panel is not set by default. The vendor ha...

6.9CVSS0.00826EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2026/01/09 11:53 a.m.•10 views

CVE-2025-66050 No password set for administrative account in Vivotek IP7137 cameras

Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions...

9.3CVSS8.1AI score0.00392EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2026/01/09 11:53 a.m.•77 views

CVE-2025-66050 No password set for administrative account in Vivotek IP7137 cameras

Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions...

9.3CVSS0.00392EPSS
SaveExploits0References1
CVE
CVE
•added 2026/01/09 11:53 a.m.•37 views

CVE-2025-66050

CVE-2025-66050 (Vivotek IP7137, firmware 0200a) is linked to multiple issues: path traversal (CVE-2025-66051), information disclosure via RTSP without authentication (CVE-2025-66049), and command injection through /cgi-bin/admin/setparam.cgi (CVE-2025-66052). All references indicate default admin...

9.8CVSS8.1AI score0.00392EPSS
SaveExploits0References1Affected Software1
Vulnrichment
Vulnrichment
•added 2026/01/09 11:53 a.m.•7 views

CVE-2025-66049 Unprotected RTSP stream in Vivotek IP7137 cameras

Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed,...

8.7CVSS7AI score0.00411EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2026/01/09 11:53 a.m.•55 views

CVE-2025-66049 Unprotected RTSP stream in Vivotek IP7137 cameras

Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed,...

8.7CVSS0.00411EPSS
SaveExploits0References1
CVE
CVE
•added 2026/01/09 11:53 a.m.•60 views

CVE-2025-66049

Affected product: Vivotek IP7137 camera with firmware 0200a. Vulnerabilities: (1) information disclosure via RTSP on port 8554 without authentication, exposing live feed; (2) command injection via /cgi-bin/admin/setparam.cgi with parameter system_ntpIt, exploitable by an admin user; (3) path trav...

8.7CVSS7AI score0.00411EPSS
SaveExploits0References1Affected Software1
Positive Technologies
Positive Technologies
•added 2026/01/09 12:00 a.m.•33 views

PT-2026-1855

Name of the Vulnerable Software and Affected Versions Vivotek IP7137 camera versions prior to firmware version 0200a Description The Vivotek IP7137 camera is susceptible to a path traversal issue. An authenticated attacker can potentially access resources outside the intended webroot directory by...

8.7CVSS6.1AI score0.00826EPSS
SaveExploits0References4
Rows per page
Query Builder