Lucene search
+L

335 matches found

Positive Technologies
Positive Technologies
added 2024/02/29 12:0 a.m.9 views

PT-2024-21419 · Vivotek · Vivotek Network Cameras

Name of the Vulnerable Software and Affected Versions: vivotek Network Camera version v.FD8166A-VVTK-0204j Description: An issue in the vivotek Network Camera allows a remote attacker to execute arbitrary code via a crafted payload to the "upload file.cgi" component. Recommendations: For version...

9.8CVSS7.4AI score0.01107EPSS
SaveExploits0References6
Vulnrichment
Vulnrichment
added 2024/02/29 12:0 a.m.15 views

CVE-2024-26548

An issue in vivotek Network Camera v.FD8166A-VVTK-0204j allows a remote attacker to execute arbitrary code via a crafted payload to the uploadfile.cgi component...

7.8AI score0.01107EPSS
SaveExploits0References1
CNNVD
CNNVD
added 2021/04/28 12:0 a.m.8 views

Vivotek VIVOTEK IP Camera 操作系统命令注入漏洞

Vivotek VIVOTEK IP Camera is an IP camera from Vivotek, Taiwan, China. The IP camera device suffers from an operating system command injection vulnerability, which originates from the NTP Server configuration not being verified with special parameters. This vulnerability can be exploited by a...

9CVSS7.7AI score0.03786EPSS
SaveExploits0References5
Check Point Advisories
Check Point Advisories
added 2021/01/25 12:0 a.m.21 views

VIVOTEK Network Camera Directory Traversal (CVE-2017-9829)

A directory traversal vulnerability exists in VIVOTEK Network Cameras. Successful exploitation of this vulnerability could allow an attacker to access arbitrary files on the affected system...

5CVSS5.5AI score0.68744EPSS
SaveExploits1
NVD
NVD
added 2020/05/28 1:15 p.m.21 views

CVE-2020-11950

VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x and before XXXXX-VVTK-0XXXXBeta2 allows an authenticated user to upload and execute a script with resultant execution of OS commands. For example, this affects IT9388-HT devices...

9CVSS8.8AI score0.02685EPSS
SaveExploits0References1
OSV
OSV
added 2020/05/28 1:15 p.m.5 views

CVE-2020-11950

VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x and before XXXXX-VVTK-0XXXXBeta2 allows an authenticated user to upload and execute a script with resultant execution of OS commands. For example, this affects IT9388-HT devices...

8.8CVSS7.4AI score0.02685EPSS
SaveExploits0References1
OSV
OSV
added 2020/05/28 1:15 p.m.6 views

CVE-2020-11949

testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x and before XXXXX-VVTK-0XXXXBeta2 allows an authenticated user to obtain arbitrary files from a camera's local filesystem. For example, this affects IT9388-HT devices...

6.5CVSS6.7AI score0.01194EPSS
SaveExploits0References1
NVD
NVD
added 2020/05/28 1:15 p.m.15 views

CVE-2020-11949

testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x and before XXXXX-VVTK-0XXXXBeta2 allows an authenticated user to obtain arbitrary files from a camera's local filesystem. For example, this affects IT9388-HT devices...

6.5CVSS6.3AI score0.01194EPSS
SaveExploits0References1
Prion
Prion
added 2020/05/28 1:15 p.m.22 views

Design/Logic Flaw

VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x and before XXXXX-VVTK-0XXXXBeta2 allows an authenticated user to upload and execute a script with resultant execution of OS commands. For example, this affects IT9388-HT devices...

9CVSS8.6AI score0.02685EPSS
SaveExploits0References1Affected Software200
Prion
Prion
added 2020/05/28 1:15 p.m.24 views

Code injection

testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x and before XXXXX-VVTK-0XXXXBeta2 allows an authenticated user to obtain arbitrary files from a camera's local filesystem. For example, this affects IT9388-HT devices...

4CVSS6.3AI score0.01194EPSS
SaveExploits0References1Affected Software193
Cvelist
Cvelist
added 2020/05/28 12:44 p.m.22 views

CVE-2020-11950

VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x and before XXXXX-VVTK-0XXXXBeta2 allows an authenticated user to upload and execute a script with resultant execution of OS commands. For example, this affects IT9388-HT devices...

8.8AI score0.02685EPSS
SaveExploits0References1
CVE
CVE
added 2020/05/28 12:44 p.m.154 views

CVE-2020-11950

CVE-2020-11950 affects VIVOTEK Network Cameras prior to XXXXX-VVTK-2.2002.xx.01x and prior to XXXXX-VVTK-0XXXX_Beta2, where an authenticated user can upload and execute a script, resulting in OS command execution (example affected device: IT9388-HT).

9CVSS8.6AI score0.02685EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2020/05/28 12:43 p.m.157 views

CVE-2020-11949

CVE-2020-11949 affects VIVOTEK Network Cameras and their web service (testserver.cgi) before XXXXX-VVTK-2.2002.xx.01x and before XXXXX-VVTK-0XXXX_Beta2. An authenticated user can obtain arbitrary files from a camera’s local filesystem (affecting devices such as IT9388-HT). The underlying cause is...

6.5CVSS6.3AI score0.01194EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/05/28 12:43 p.m.24 views

CVE-2020-11949

testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x and before XXXXX-VVTK-0XXXXBeta2 allows an authenticated user to obtain arbitrary files from a camera's local filesystem. For example, this affects IT9388-HT devices...

6.3AI score0.01194EPSS
SaveExploits0References1
NVD
NVD
added 2020/01/24 7:15 p.m.20 views

CVE-2013-1598

A Command Injection vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via the system.ntp parameter to the farseer.out binary file, which cold let a malicious user execute arbitrary code...

9CVSS9AI score0.20463EPSS
SaveExploits6References5
NVD
NVD
added 2020/01/24 7:15 p.m.17 views

CVE-2013-1597

A Directory Traversal vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via a specially crafted GET request, which could let a malicious user obtain user credentials...

6.5CVSS6.3AI score0.14193EPSS
SaveExploits6References5
Prion
Prion
added 2020/01/24 7:15 p.m.12 views

Command injection

A Command Injection vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via the system.ntp parameter to the farseer.out binary file, which cold let a malicious user execute arbitrary code...

9CVSS7.9AI score0.20463EPSS
SaveExploits6References5Affected Software1
Prion
Prion
added 2020/01/24 7:15 p.m.15 views

Directory traversal

A Directory Traversal vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via a specially crafted GET request, which could let a malicious user obtain user credentials...

4CVSS6.8AI score0.14193EPSS
SaveExploits6References5Affected Software1
Cvelist
Cvelist
added 2020/01/24 6:32 p.m.24 views

CVE-2013-1598

A Command Injection vulnerability exists in Vivotek PT7135 IP Cameras 0300a and 0400a via the system.ntp parameter to the farseer.out binary file, which cold let a malicious user execute arbitrary code...

9.6AI score0.20463EPSS
SaveExploits6References5
CVE
CVE
added 2020/01/24 6:32 p.m.63 views

CVE-2013-1598

Vivotek PT7135 IP cameras with firmware 0300a and 0400a are affected by CVE-2013-1598, an OS command injection in the binary farseer.out via the system.ntp parameter that lets an attacker execute arbitrary commands. The vulnerability spans pre-auth (0300a) and post-auth (0400a) access in the admi...

9CVSS9.4AI score0.20463EPSS
SaveExploits6References5Affected Software1
Rows per page
Query Builder