Lucene search
+L

12 matches found

EUVD
EUVD
•added 2025/10/07 12:30 a.m.•20 views

EUVD-2017-17361

Malware in sbrugna...

7.5CVSS7.3AI score0.02705EPSS
SaveExploits1References5
NCSC
NCSC
•added 2022/09/14 12:00 a.m.•22 views

Vulnerabilities fixed in Zoom

Vulnerabilities have been fixed in Zoom. The vulnerabilities allow a malicious person to carry out attacks that result in the following categories of damage: Manipulation of data Circumvention of security measure Accessing sensitive data The vulnerabilities with characteristics CVE-2022-28758 and...

8.6CVSS6.7AI score0.00694EPSS
SaveExploits0
CNNVD
CNNVD
•added 2021/04/02 12:00 a.m.•24 views

de Consumentenbond Sannce Smart HD Baby Monitor 授权问题漏洞

The de Consumentenbond Sannce Smart HD Baby Monitor is a webcam from de Consumentenbond in the Netherlands. It provides monitoring functionality. A security vulnerability exists in the Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices, which can be exploited by an attacker to gain...

7.5CVSS7.4AI score0.01668EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/04/02 12:00 a.m.•13 views

CVE-2019-20464: Improper Authentication

An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. By default, a mobile application is used to stream over UDP. However, the device offers many more services that also enable streaming. Although the service used by the mobile application requires a...

7.5CVSS5.8AI score0.01668EPSS
SaveExploits1References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/07/02 12:00 a.m.•11 views

CVE-2017-8405: Improper Authentication

An issue was discovered on D-Link DCS-1130 and DCS-1100 devices. The binary rtspd in /sbin folder of the device handles all the rtsp connections received by the device. It seems that the binary loads at address 0x00012CF4 a flag called "Authenticate" that indicates whether a user should be...

7.5CVSS5.8AI score0.02656EPSS
SaveExploits1References2
NVD
NVD
•added 2019/06/17 10:15 p.m.•36 views

CVE-2017-10723

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that an attacker connected to the device Wi-Fi SSID can exploit a memory corruption issue and execute remote code on the device. This device acts as an Endoscope camera that allows...

8.8CVSS9.2AI score0.02522EPSS
SaveExploits1References3
Cvelist
Cvelist
•added 2019/06/17 9:28 p.m.•44 views

CVE-2017-10718

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that any malicious user connecting to the device can change the default SSID and password thereby denying the owner an access to his/her own device. This device acts as an Endoscop...

6.6AI score0.0183EPSS
SaveExploits1References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/06/17 12:00 a.m.•9 views

CVE-2017-10719: Exposure of Sensitive Information to an Unauthorized Actor

Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that the device has default Wi-Fi credentials that are exactly the same for every device. This device acts as an Endoscope camera that allows its users to use it in various...

6.5CVSS5.8AI score0.02031EPSS
SaveExploits1References2
Positive Technologies
Positive Technologies
•added 2019/06/17 12:00 a.m.•5 views

PT-2019-7865

Name of the Vulnerable Software and Affected Versions Shekar Endoscope affected versions not specified Description The Shekar Endoscope device has Telnet functionality enabled by default in its most recent firmware. This device is used in various industrial systems, car garages, and medical clini...

6.5CVSS0.01595EPSS
SaveExploits1References5
Positive Technologies
Positive Technologies
•added 2019/06/17 12:00 a.m.•6 views

PT-2019-7862

Name of the Vulnerable Software and Affected Versions Shekar Endoscope affected versions not specified Description The issue concerns the Shekar Endoscope, a device used in various industrial settings, car garages, and medical clinics to access hard-to-reach areas. A malicious user connecting to...

6.5CVSS0.0183EPSS
SaveExploits1References5
NVD
NVD
•added 2013/10/16 10:52 a.m.•24 views

CVE-2013-5535

The analytics page on Cisco Video Surveillance 4000 IP cameras has hardcoded credentials, which allows remote attackers to watch the video feed by leveraging knowledge of the password, aka Bug IDs CSCuj70402 and CSCuj70419...

6.4CVSS6.7AI score0.01154EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2013/09/30 12:00 a.m.•8 views

CVE-2013-3417: Improper Authentication

The administrative web interface in Cisco Video Surveillance Operations Manager does not properly perform authentication, which allows remote attackers to watch video feeds via a crafted URL, aka Bug ID CSCtg72262...

5CVSS5.8AI score0.01284EPSS
SaveExploits0References2
Rows per page
Query Builder