Lucene search
+L

9 matches found

Cvelist
Cvelist
added 2025/10/15 1:55 p.m.13 views

CVE-2025-60015 F5OS out-of-bounds write vulnerability

An out-of-bounds write vulnerability exists in F5OS-A and F5OS-C that could lead to memory corruption. Note: Software versions which have reached End of Technical Support EoTS are not evaluated...

6.9CVSS0.00196EPSS
SaveExploits0References1
HPE Security Bulletins
HPE Security Bulletins
added 2024/11/12 12:0 a.m.6 views

HPESBUX04729 rev.1 - HP-UX NTP Software, Denial of Service (DoS)

Potential Security Impact: Remote: Denial of Service DoS, Unauthorized Write Access to the File System, Null pointer dereference SUPPORTED SOFTWARE VERSIONS: ONLY impacted versions are listed. HP-UX NTP Software - Prior to C.4.2.8.7.0 CVSS Scores: | CVE | CVSS Vector | Base Score | | --- | --- |...

6.4CVSS6.1AI score0.00703EPSS
SaveExploits0
OSV
OSV
added 2021/12/27 7:15 p.m.8 views

CVE-2021-43552

The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX PIC iX Versions B.02, C.02, and C.03...

5.5CVSS5.8AI score0.00213EPSS
SaveExploits0References1
OSV
OSV
added 2021/12/27 7:15 p.m.7 views

CVE-2021-43548

Patient Information Center iX PIC iX Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly...

6.5CVSS5.8AI score0.00366EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2021/11/18 3:34 p.m.2 views

CVE-2021-33017

The standard access path of the IntelliBridge EC 40 and 60 Hub C.00.04 and prior requires authentication, but the product has an alternate path or channel that does not require authentication...

8.8CVSS7AI score0.00453EPSS
SaveExploits0References2
OSV
OSV
added 2020/09/11 2:15 p.m.10 views

CVE-2020-16224

In Patient Information Center iX PICiX Versions C.02, C.03, the software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the application on the surveillance station to...

6.5CVSS6.6AI score0.00594EPSS
SaveExploits0References2
Prion
Prion
added 2020/09/11 1:15 p.m.22 views

Design/Logic Flaw

In Patient Information Center iX PICiX Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct...

5.8CVSS8.6AI score0.00549EPSS
SaveExploits0References2Affected Software2
Positive Technologies
Positive Technologies
added 2020/09/11 12:0 a.m.10 views

PT-2020-14813 · Philips · Patient Information Center Ix

Name of the Vulnerable Software and Affected Versions: Patient Information Center iX PICiX versions B.02, C.02, C.03 Description: The software saves user-provided information into a comma-separated value CSV file, but it does not neutralize or incorrectly neutralizes special elements that could b...

5.8CVSS5AI score0.00586EPSS
SaveExploits0References4
OpenVAS
OpenVAS
added 2012/06/19 12:0 a.m.25 views

Asterisk SIP Channel Driver DoS Vulnerability

Asterisk is prone to a denial of service DoS vulnerability. SPDX-FileCopyrightText: 2012 NopSec Inc. Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-or-later CPE = "cpe:/a:digium:asterisk";...

6.5CVSS6.2AI score0.0219EPSS
SaveExploits0References1
Rows per page
Query Builder