3 matches found
Philips Tasy EMR CVE-2019-13557 Information Disclosure Vulnerability
Description Philips Tasy EMR is prone to an information-disclosure vulnerability. An attacker can exploit this issue to gain unauthorized access to sensitive information. This may lead to further attacks. Philips Tasy EMR version 3.02.1744 and prior are affected. Philips Tasy WebPortal version...
Design/Logic Flaw
In Philips Tasy EMR, Tasy EMR Versions 3.02.1744 and prior, the software incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users...
PT-2019-18165 · Philips · Philips Tasy Emr
Name of the Vulnerable Software and Affected Versions: Philips Tasy EMR versions 3.02.1744 and prior Description: The software incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users. Recommendations: For versions...