2213 matches found
CVE-2021-30195
CVE-2021-30195 affects the CODESYS V2 runtime system prior to 2.4.7.55. The vulnerability is caused by Improper Input Validation, leading to an out-of-bounds read that can cause a denial-of-service. Affected components are the CODESYS Runtime Toolkit 32‑bit full and PLCWinNT prior to 2.4.7.55. Mi...
CVE-2021-30195
CODESYS V2 runtime system before 2.4.7.55 has Improper Input Validation...
CVE-2021-30188
CVE-2021-30188 affects the CODESYS V2 runtime system SPs prior to 2.4.7.55. A stack-based buffer overflow in the affected runtime (stack-based CWE-121) can lead to denial of service and, in some cases, remote code execution. Public sources consistently identify the vulnerable component as the COD...
CVE-2021-30186
CVE-2021-30186 affects CODESYS V2 runtime system SP prior to 2.4.7.55, where a heap-based buffer overflow is triggered by a crafted request. Public sources describe this as a vulnerability in the CODESYS Runtime Toolkit/PLCWinNT stack, enabling denial-of-service and, per ICS background, potential...
CVE-2021-30186
CODESYS V2 runtime system SP before 2.4.7.55 has a Heap-based Buffer Overflow...
Command injection
CODESYS V2 runtime system SP before 2.4.7.55 has Improper Neutralization of Special Elements used in an OS Command...
CVE-2021-30193
CVE-2021-30193 affects CODESYS V2 Web-Server before 1.1.9.20. The vulnerability is an Out-of-bounds Write in the web server component, enabling crafted requests to write to arbitrary memory in the CODESYS Control runtime (potential remote code execution or crash). Affected products include CODESY...
CVE-2021-30193
CODESYS V2 Web-Server before 1.1.9.20 has an Out-of-bounds Write...
CVE-2021-30192
CVE-2021-30192 affects CODESYS V2 Web-Server prior to 1.1.9.20. The vulnerability is an Improperly Implemented Security Check (CWE-358) that enables bypass of security protections on the web server, with consequences including the potential to read/write values or upload boot‑related files withou...
CVE-2021-30192
CODESYS V2 Web-Server before 1.1.9.20 has an Improperly Implemented Security Check...
CVE-2021-30190
CODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control...
CVE-2021-30190
The CVE-2021-30190 entry covers CODESYS V2 Web-Server prior to version 1.1.9.20 with an Improper Access Control flaw. Public sources (ICSA-21-173-02, CNVD/NVD, 3rd-party advisories) describe that unauthorized remote requests can bypass authentication to read or write values on the PLC via the web...
CVE-2021-30187
CODESYS V2 runtime system SP before 2.4.7.55 has Improper Neutralization of Special Elements used in an OS Command...
CVE-2021-30187
Summary: CVE-2021-30187 affects the CODESYS V2 Runtime System SPs prior to 2.4.7.55, enabling an OS command injection via the SysFile library. Affected product/component: CODESYS Control/Runtime Toolkit 32‑bit full SP before 2.4.7.55 (CODESYS V2 Runtime System). Root cause: Improper neutralizatio...
3S-Smart Software Solutions CODESYS V2 Web-Server 缓冲区错误漏洞
3S-Smart Software Solutions CODESYS V2 Web-Server is an application from 3S-Smart Software Solutions, Germany. A web server. An out-of-bounds read vulnerability exists in 3S-Smart Software Solutions CODESYS V2 Web-Server versions prior to 1.1.9.20, which can be exploited by an attacker with the...
CODESYS V2 Web-Server 缓冲区错误漏洞
3S-Smart Software Solutions CODESYS V2 Web-Server is an application from 3S-Smart Software Solutions, Germany. A web server. A buffer overflow vulnerability exists in 3S-Smart Software Solutions CODESYS V2 Web-Server versions prior to 1.1.9.20, which can be exploited by an attacker with the help ...
Input validation
The USB firmware update script of homee Brain Cube v2 2.28.2 and 2.28.4 devices allows an attacker with physical access to install compromised firmware. This occurs because of insufficient validation of the firmware image file and can lead to code execution on the device...
Hardcoded credentials
homee Brain Cube v2 2.28.2 and 2.28.4 devices have sensitive SSH keys within downloadable and unencrypted firmware images. This allows remote attackers to use the support server as a SOCKS proxy...
CVE-2020-24396
homee Brain Cube v2 2.28.2 and 2.28.4 devices have sensitive SSH keys within downloadable and unencrypted firmware images. This allows remote attackers to use the support server as a SOCKS proxy...
CVE-2020-24396
CVE-2020-24396 affects homee Brain Cube v2 (firmware 2.28.2 and 2.28.4). The issue is that sensitive SSH keys are stored within downloadable and unencrypted firmware images, enabling remote attackers to use the support server as a SOCKS proxy. Documented impact is exposure of credentials and pote...