32 matches found
Code injection
A vulnerability has been identified in SIMATIC Drive Controller family All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC incl. SIPLUS variants All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 incl. SIPLUS variants All versions = V20.8, SIMATIC S7-1200 CPU family incl. SIPL...
CVE-2019-10943
A vulnerability has been identified in SIMATIC Drive Controller family All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC incl. SIPLUS variants All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 incl. SIPLUS variants All versions = V20.8, SIMATIC S7-1200 CPU family incl. SIPL...
Siemens S7-1200 Series PLC CPU User Program Block Protection Remote Bypass
Binary data 142.prm...
CSRF vulnerability and missing permission checks in AbsInt Astrée Plugin allowed launching programs on the Jenkins controller
AbsInt Astrée Plugin did not perform permission checks on a method implementing form validation. This allowed users with Overall/Read access to Jenkins to run a user-specified program on the Jenkins controller. Additionally, this form validation method did not require POST requests, resulting in ...
Allen Bradley Micrologix 1400 Series B FRN Access Control Vulnerability (CNVD-2018-08279)
Allen Bradley Micrologix 1400 Series B FRN is a programmable logic controller from Rockwell Automation. An access control vulnerability exists in the data, program, and function file permissions function in Allen Bradley Micrologix 1400 Series B FRN 21.2 and earlier. When a memory module is not...
PLC Blaster Worm Targets Industrial Control PLCs
LAS VEGAS – Security researchers at Black Hat USA described a proof-of-concept worm that targets weaknesses within automated industrial control systems used to manage critical infrastructure and manufacturing. The worm, according to OpenSource Security, has the capability to autonomously search f...
CVE-2016-2846
Siemens SIMATIC S7-1200 CPU devices before 4.0 allow remote attackers to bypass a "user program block" protection mechanism via unspecified vectors...
Design/Logic Flaw
Siemens SIMATIC S7-1200 CPU devices before 4.0 allow remote attackers to bypass a "user program block" protection mechanism via unspecified vectors...
CVE-2016-2846
Siemens SIMATIC S7-1200 CPU devices before 4.0 allow remote attackers to bypass a "user program block" protection mechanism via unspecified vectors...
PT-2016-5235
Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1200 CPU devices versions prior to 4.0 Description The issue allows remote attackers to bypass a user program block protection mechanism. Recommendations For versions prior to 4.0, update to version 4.0 or later to resolve t...
Siemens SIMATIC S7-1200 CPU Privilege Bypass Vulnerability
The Siemens SIMATIC S7-1200 CPU device is a small programmable controller from Siemens that meets the needs of small and medium-sized automation systems. A privilege bypass vulnerability exists in Siemens SIMATIC S7-1200 CPU versions prior to 4.0, which can be exploited by an attacker to bypass t...
CVE-2011-3006
The MyAsUtil ActiveX control in MyAsUtil5.2.0.603.dll in McAfee SaaS Endpoint Protection 5.2.1 and earlier allows remote attackers to bypass the MyASUtil.SecureObjectFactory.CreateSecureObject domain execution policy using a cross-site scripting XSS attack, execute arbitrary code using the...