CVE-2022-22805
A CWE-120: Buffer Copy without Checking Size of Input 'Classic Buffer Overflow' vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series SMT Series ID=1015: UPS 04.5 and prior, SMC Series SM...
EUVD-2022-27948
A CWE-120: Buffer Copy without Checking Size of Input 'Classic Buffer Overflow' vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series SMT Series ID=1015: UPS 04.5 and prior, SMC Series SM...
CVE-2022-22805
CVE-2022-22805 is a TLS buffer overflow vulnerability in APC Schneider Electric Smart-UPS devices using SmartConnect TLS; impact is remote code execution via unauthenticated network packets during TLS reassembly. Affected lines include SmartConnect SMT, SMC, SMTL, SCL, SMX series (various IDs up ...
CVE-2022-0715
A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series SMT Series ID=18: UPS 09.8 and prior / SMT Series...
CVE-2022-0715
CVE-2022-0715 describes an improper authentication vulnerability in Schneider Electric APC Smart-UPS devices across multiple series (SMT/SMC/SCL/SMX/SRT and SmartConnect/SMTL), where a leaked key could authorize uploading unsigned firmware, allowing an attacker to arbitrarily change UPS behavior....
CVE-2022-0715
A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and used to upload malicious firmware. Affected Product: APC Smart-UPS Family: SMT Series SMT Series ID=18: UPS 09.8 and prior / SMT Series...
Critical Bugs Could Let Attackers Remotely Hack, Damage APC Smart-UPS Devices
Three high-impact security vulnerabilities have been disclosed in APC Smart-UPS devices that could be abused by remote adversaries as a physical weapon to access and control them in an unauthorized manner. Collectively dubbed TLStorm, the flaws "allow for complete remote takeover of Smart-UPS...
PT-2022-1931 · Apc · Apc Smart-Ups Family +1
Name of the Vulnerable Software and Affected Versions: APC Smart-UPS Family: SMT Series versions 09.8 and prior APC Smart-UPS Family: SMT Series versions 01.2 and prior APC Smart-UPS Family: SMT Series versions 03.1 and prior APC Smart-UPS Family: SMC Series versions 14.1 and prior APC Smart-UPS...
多款Schneider Electric产品数据伪造问题漏洞
The Schneider Electric APC Smart-UPS SMC Series, among others, is a product of Schneider Electric, a French company. The Schneider Electric APC Smart-UPS SMT Series is a line interactive power protection for servers, point-of-sale, routers, switches, hubs and other network equipment. The Schneide...
Schneider Electric 多款产品授权问题漏洞
The Schneider Electric APC Smart-UPS SMC Series, among others, is a product of Schneider Electric, a French company. Schneider Electric APC Smart-UPS SMT Series is a line interactive power protection for servers, point-of-sale, routers, switches, hubs and other network devices. Schneider Electric...
Zero-Click Flaws in Widely Used UPS Devices Threaten Critical Infratructure
Three critical security vulnerabilities in widely used smart uninterruptible power supply UPS devices could allow for remote takeover, meaning that malicious actors could cause business disruptions, data loss and even physical harm to critical infrastructure, researchers have found. Researchers a...
pixiv: XSS Reflected at https://sketch.pixiv.net/ Via `next_url`
Hi, I Found XSS Reflected at https://sketch.pixiv.net/ Via Success URL Follow Me : Steps : 1. Open the URL below: https://sketch.pixiv.net/resignrequest/success?nexturl=javascript%3Aalert%2F%2Fdocument.domain 2. Pop ups appear : Impact If an attacker can control a script that is executed in the...
PT-2022-1801 · Apc · Apc Smart-Ups Smc Series +1
Name of the Vulnerable Software and Affected Versions: APC Smart-UPS SMT Series versions 04.5 and prior APC Smart-UPS SMC Series versions 04.2 and prior APC Smart-UPS SMTL Series versions 02.9 and prior APC Smart-UPS SCL Series versions 02.5 and prior APC Smart-UPS SCL Series versions 03.1 and...
WordPress Power Ups for Elementor plugin <= 1.2.1 - Sensitive Information Disclosure vulnerability
Sensitive Information Disclosure vulnerability discovered in WordPress Power Ups for Elementor plugin versions = 1.2.1. Solution Update the WordPress Power Ups for Elementor plugin to the latest available version at least 1.2.2...
WordPress Power Ups for Elementor plugin <= 1.2.1 - Toggle The Debug Mode via Cross-Site Request Forgery (CSRF) vulnerability
Toggle The Debug Mode via Cross-Site Request Forgery CSRF vulnerability discovered in WordPress Power Ups for Elementor plugin versions = 1.2.1. Solution Update the WordPress Power Ups for Elementor plugin to the latest available version at least 1.2.2...
CVE-2021-22813
A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products:...
CVE-2021-22814
A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply UPS using NMC2 including Smart-UPS,...
CVE-2021-22812
A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power...
CVE-2021-22811
A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply UP...
Cross site scripting
A CWE-79: Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products:...