Lucene search
K

8 matches found

Tenable Nessus
Tenable Nessus
added 2024/07/22 12:0 a.m.12 views

Siemens SITOP UPS1600 Out-of-bounds Write (CVE-2023-26554)

mstolfp in libntp/mstolfp.c in NTP 4.2.8p15 has an out-of-bounds write when adding a '\0' character. An adversary may be able to attack a client ntpq process, but cannot attack ntpd. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...

5.6CVSS6.8AI score0.0035EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2024/07/22 12:0 a.m.24 views

Siemens SITOP UPS1600 Out-of-bounds Write (CVE-2023-26553)

mstolfp in libntp/mstolfp.c in NTP 4.2.8p15 has an out-of-bounds write when copying the trailing number. An adversary may be able to attack a client ntpq process, but cannot attack ntpd. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...

5.6CVSS6.8AI score0.00681EPSS
Exploits0References3
Tenable Nessus
Tenable Nessus
added 2024/07/22 12:0 a.m.23 views

Siemens SITOP UPS1600 Out-of-Bounds Write (CVE-2023-26552)

mstolfp in libntp/mstolfp.c in NTP 4.2.8p15 has an out-of-bounds write when adding a decimal point. An adversary may be able to attack a client ntpq process, but cannot attack ntpd. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...

5.6CVSS6.8AI score0.00282EPSS
Exploits0References3
ICS
ICS
added 2024/06/11 12:0 a.m.24 views

Siemens SITOP UPS1600

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...

5.6CVSS6.5AI score0.00681EPSS
Exploits0References12
Tenable Nessus
Tenable Nessus
added 2019/07/09 12:0 a.m.10 views

Siemens SITOP UPS1600 20A Uninterrupted Power Supply with Ethernet/PROFINET interface

Binary data 764693.prm...

7.3AI score
Exploits0
Tenable Nessus
Tenable Nessus
added 2019/07/09 12:0 a.m.21 views

Siemens SITOP UPS1600 10A Uninterrupted Power Supply with Ethernet/PROFINET interface

Binary data 764692.prm...

7.3AI score
Exploits0
Tenable Nessus
Tenable Nessus
added 2019/07/09 12:0 a.m.18 views

Siemens SITOP UPS1600 40A Uninterrupted Power Supply with Ethernet/PROFINET interface

Binary data 764694.prm...

7.3AI score
Exploits0
ICS
ICS
added 2017/05/09 12:0 a.m.22 views

Siemens devices using the PROFINET Discovery and Configuration Protocol (Update H)

CVSS v3 6.5 ATTENTION: Exploitable from an adjacent network/low skill level to exploit. Vendor: Siemens Equipment: Devices using the PROFINET Discovery and Configuration Protocol DCP Vulnerability: Denial of Service UPDATE INFORMATION This updated advisory is a follow-up to the updated advisory...

7.1CVSS0.3AI score0.02335EPSS
Exploits0References75
Rows per page
Query Builder