ICS
ICS
added 2022/03/08 12:00 a.m.85 views

Siemens Polarion ALM

1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Polarion ALM Vulnerability: Cross-site Scripting 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-22-069-08 Siemens Polarion ALM that...

6.1CVSS6.9AI score0.00761EPSS
SaveExploits0References11
ICS
ICS
added 2022/02/03 12:00 a.m.290 views

Sensormatic PowerManage (Update A)

1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Sensormatic Electronics, LLC, a subsidiary of Johnson Controls Inc Equipment: PowerManage Vulnerability: Improper Input Validation 2. UPDATE INFORMATION This update advisory is a follow-up to the...

10CVSS10AI score0.99999EPSS
SaveExploits361References5
ICS
ICS
added 2021/12/16 12:00 a.m.76 views

Siemens Healthineers syngo fastView (Update A)

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Siemens Healthineers, a subsidiary of Siemens Equipment: syngo fastView --------- Begin Update A Part 1 of 2 -------- Vulnerabilities: Out-of-bounds Write, Write-what-where Condition --------- End Update A Part 1 of 2...

7.8CVSS8.1AI score0.00323EPSS
SaveExploits0References4
ICS
ICS
added 2021/12/02 12:00 a.m.81 views

Hitachi Energy APM Edge

1. EXECUTIVE SUMMARY CVSS v3 8.2 ATTENTION: Low attack complexity Vendor: Hitachi Energy Equipment: Transformer Asset Performance Management APM Edge Vulnerability: Reliance on Uncontrolled Component 2. UPDATE OR REPOSTED INFORMATION This updated advisory is a follow-up to the original advisory...

7.8AI score
SaveExploits0References4
ICS
ICS
added 2021/11/11 12:00 a.m.59 views

Siemens Climatix POL909 (Update A)

1. EXECUTIVE SUMMARY CVSS v3 6.4 ATTENTION: Exploitable remotely Vendor: Siemens --------- Begin Update A Part 1 of 3 --------- Equipment: Climatix POL909 AWM and AWB modules --------- End Update A Part 1 of 3 --------- Vulnerability: Missing Encryption of Sensitive Data 2. RISK EVALUATION...

7.4CVSS7.5AI score0.00408EPSS
SaveExploits0References5
ICS
ICS
added 2021/10/07 12:00 a.m.132 views

InHand Networks IR615 Router (Update A)

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: InHand Networks Equipment: IR615 Router Vulnerabilities: Improper Restriction of Rendered UI Layers or Frames, Improper Authorization, Cross-site Request Forgery, Inadequate Encryption Strength, Imprope...

9.8CVSS9.6AI score0.02762EPSS
SaveExploits0References5
ICS
ICS
added 2021/09/14 12:00 a.m.51 views

Siemens SIPROTEC 5 (Update A)

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIPROTEC 5 Vulnerability: Improper Input Validation 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-21-257-16 Siemens SIPROTEC 5 that...

7.5CVSS7.9AI score0.01433EPSS
SaveExploits0References11
ICS
ICS
added 2021/09/14 12:00 a.m.70 views

Siemens RUGGEDCOM ROX (Update A)

1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM ROX --------- Begin Update A Part 1 of 2 --------- Vulnerabilities: Improper Privilege Management, Execution with Unnecessary Privileges, Improper Handling of Insufficient...

9CVSS8.3AI score0.01606EPSS
SaveExploits0References11
ICS
ICS
added 2021/08/10 12:00 a.m.106 views

Siemens SIMATIC CP (Update A)

1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC Vulnerabilities: Out-of-Bounds Read, Use After Free 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-21-222-07 Siemens SIMATIC...

9CVSS9.1AI score0.12045EPSS
SaveExploits1References11
ICS
ICS
added 2021/07/13 12:00 a.m.205 views

Schneider Electric Modicon Controllers and Software (Update A)

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor : Schneider Electric Equipment : EcoStruxure Control Expert, EcoStruxure Process Expert, SCADAPack RemoteConnect x70, SCADAPack x70 RTUs, and Modicon M580 and M340 control products Vulnerabilities :...

9.1CVSS8.4AI score0.01023EPSS
SaveExploits0References5
ICS
ICS
added 2021/07/13 12:00 a.m.60 views

Siemens SINUMERIK ONE and SINUMERIK MC (Update A)

1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINUMERIK ONE and SINUMERIK MC Vulnerability: Improper Restriction of Operations within the Bounds of a Memory Buffer 2. UPDATE INFORMATION This updated advisory is a follow-up to the...

9.8CVSS10AI score0.05184EPSS
SaveExploits0References11
ICS
ICS
added 2021/06/29 12:00 a.m.209 views

AVEVA System Platform (Update A)

1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable from adjacent network/low attack complexity Vendor: AVEVA Software, LLC Equipment: System Platform Vulnerabilities: Missing Authentication for Critical Function, Uncaught Exception, Path Traversal, Origin Validation Error, Improper...

9.8CVSS8.4AI score0.0121EPSS
SaveExploits0References5
ICS
ICS
added 2021/05/17 12:00 a.m.313 views

ICSA-21-040-06_Siemens JT2Go and Teamcenter Visualization (Update A)

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: JT2Go and Teamcenter Visualization Vulnerabilities: Out-of-bounds Read, Improper Restriction of Operations within the Bounds of a Memory Buffer, Stack-based Buffer overflow, Out-of-Bounds Write, Type...

8.8CVSS8.7AI score0.03991EPSS
SaveExploits0References11
ICS
ICS
added 2021/04/13 12:00 a.m.208 views

Siemens Nucleus Products DNS Module (Update A)

1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens --------- Begin Update A Part 1 of 3 --------- Equipment: Nucleus NET, Nucleus Source Code, Capital VSTAR --------- End Update A Part 1 of 3 --------- Vulnerabilities: Out-of-bounds Write, Use...

8.1CVSS8.7AI score0.07194EPSS
SaveExploits0References11
ICS
ICS
added 2021/03/09 12:00 a.m.74 views

Siemens SCALANCE and RUGGEDCOM Devices (Update A)

1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE and RUGGEDCOM Devices Vulnerability: Stack-based Buffer Overflow 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-21-068-03...

8.8CVSS9.2AI score0.00859EPSS
SaveExploits0References11
ICS
ICS
added 2021/02/09 12:00 a.m.345 views

Open Design Alliance Drawings SDK (Update A)

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Open Design Alliance Equipment: Drawings SDK --------- Begin Update A Part 1 of 3 --------- Vulnerabilities: Stack-based Buffer Overflow, Type Confusion, Untrusted Pointer Dereference, Incorrect Type Conversion or Cast,...

8.8CVSS8.8AI score0.03991EPSS
SaveExploits0References11
ICS
ICS
added 2021/01/12 12:00 a.m.110 views

Siemens SCALANCE X Products (Update B)

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE X Products Vulnerabilities: Missing Authentication for Critical Function, Heap-based Buffer Overflow 2. UPDATE INFORMATION This updated advisory is a follow-up to the...

9.8CVSS9.3AI score0.01652EPSS
SaveExploits0References11
ICS
ICS
added 2020/11/10 12:00 a.m.62 views

Siemens SIMATIC S7-300 CPUs and SINUMERIK Controller (Update A)

1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: SIMATIC S7-300 CPUs and SINUMERIK Controller Vulnerability: Uncontrolled Resource Consumption 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-20-315-04...

7.8CVSS7.6AI score0.01666EPSS
SaveExploits0References11
ICS
ICS
added 2020/08/11 12:00 a.m.78 views

Yokogawa CENTUM (Update A)

1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Yokogawa Equipment: CENTUM Vulnerabilities: Improper Authentication, Path Traversal 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-20-224-01...

9.8CVSS10AI score0.01587EPSS
SaveExploits0References5
ICS
ICS
added 2020/06/25 12:00 a.m.108 views

ENTTEC Lighting Controllers (Update A)

1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low skill level to exploit/public exploits are available Vendor: ENTTEC Equipment: Datagate Mk2, Storm 24, Pixelator, E-Streamer Mk2 Vulnerabilities: Use of Hard-coded Cryptographic Key, Cross-site Scripting, Improper Access Control...

10CVSS8.5AI score0.02016EPSS
SaveExploits4References5