Lucene search
+L

6393 matches found

CVE
CVE
added 2018/09/26 7:0 p.m.52 views

CVE-2018-8856

This CVE affects Philips e-Alert Unit (non-medical device), Versions R2.1 and prior. The issue is the use of a hard-coded cryptographic key for internal data encryption (CWE-798), which enables high-severity impact. Per the connected docs, CVSS v3 base score is 9.8 (critical) with remote/network ...

9.8CVSS9.3AI score0.01378EPSS
SaveExploits0References3Affected Software1
CVE
CVE
added 2018/09/26 7:0 p.m.48 views

CVE-2018-8846

Philips e-Alert Unit (non-medical device), Version R2.1 and prior, contains an input handling flaw that allows cross-site scripting when user-controlled data is placed in web page output. This CVE (CVE-2018-8846) is documented with a CWE-79 XSS pattern and a CVSS v3 base score of 7.1 (AV:N/AC:L/P...

6.1CVSS5.8AI score0.01259EPSS
SaveExploits0References3Affected Software1
CVE
CVE
added 2018/09/26 7:0 p.m.53 views

CVE-2018-8848

Philips e-Alert Unit (non-medical device), Version R2.1 and prior, is affected by CVE-2018-8848 due to incorrect default permissions that expose an object to an unintended actor. This CVE is categorized under CWE-276 (Incorrect Default Permissions). The issue was observed during installation and ...

7.5CVSS7.4AI score0.02026EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2018/09/26 7:0 p.m.25 views

CVE-2018-8854

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software does not properly restrict the size or amount of resources requested or influenced by an actor, which can be used to consume more resources than intended...

7.4AI score0.02523EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2018/09/26 7:0 p.m.26 views

CVE-2018-8844

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request...

8.6AI score0.00873EPSS
SaveExploits0References3
CVE
CVE
added 2018/09/26 7:0 p.m.50 views

CVE-2018-8844

Philips e-Alert Unit (non‑medical device), Version R2.1 and prior, contains a Cross‑Site Request Forgery (CSRF) weakness in which the web application does not sufficiently verify that a user’s request is intentional. This CSRF issue could allow an attacker to perform unauthorized operations when ...

8.8CVSS8.5AI score0.00873EPSS
SaveExploits0References3Affected Software1
CVE
CVE
added 2018/09/26 7:0 p.m.50 views

CVE-2018-8854

CVE-2018-8854 affects Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The issue is Uncontrolled Resource Consumption (Resource Exhaustion): the software does not properly restrict the size/amount of resources requested, allowing an attacker to consume resources. Affects Philips...

7.5CVSS7.3AI score0.02523EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2018/09/26 7:0 p.m.27 views

CVE-2018-8848

Philips e-Alert Unit non-medical device, Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor...

7.5AI score0.02026EPSS
SaveExploits0References3
CVE
CVE
added 2018/09/26 7:0 p.m.58 views

CVE-2018-14803

Philips e-Alert Unit (non-medical device), Version R2.1 and prior, is affected by CVE-2018-14803 which describes an information-disclosure vulnerability: an attacker could obtain extraneous product information (e.g., OS/software components) via HTTP response headers that are normally not exposed....

5.3CVSS4.8AI score0.01738EPSS
SaveExploits0References3Affected Software1
Microsoft KB
Microsoft KB
added 2018/09/18 4:40 a.m.25 views

Description of the cumulative update for Lync Server 2010, Core Components: April 2011

Describes the cumulative update for Lync Server 2010, Core Components that is dated April 2011.SummaryThis article describes the Microsoft Lync Server 2010, Core Components issue that is fixed in the cumulative update for Lync Server 2010, Core Components that is dated April, 2011. This article...

0.3AI score
SaveExploits0
BDU FSTEC
BDU FSTEC
added 2018/09/11 12:0 a.m.9 views

The vulnerability of the input data processing module in Philips e-Alert Unit’s medical system visualization software allows a intruder to gain access to control resources or execute arbitrary code.

The vulnerability of the input data processing module in Philips e-Alert Unit’s medical system visualization solution arises from incorrect validation of input data. Exploiting this vulnerability can allow an attacker to gain access to resources or execute arbitrary codes...

10CVSS5.8AI score0.03834EPSS
SaveExploits0References2
BDU FSTEC
BDU FSTEC
added 2018/09/11 12:0 a.m.12 views

The vulnerability of the encryption module for internal data in Philips e-Alert Unit software solutions allows a intruder to gain full access to the device’s data.

The vulnerability of the encryption module for internal data in Philips e-Alert Unit medical visualization systems arises from the rigid encoding of the cryptographic key used for encrypting internal data. Exploiting this vulnerability could allow an attacker, operating remotely, to gain full...

10CVSS5.5AI score0.01378EPSS
SaveExploits0References2
Pen Test Partners Blog
Pen Test Partners Blog
added 2018/09/07 10:20 a.m.53 views

Automotive theft affects shipping security

Cars and ships – there’s not that much in common with two areas that we carry out a lot of research in to. One uses CAN for safety critical controls, the other uses serial and +/- 10V. Yet, security of the two sectors is linked through vehicle theft and fraud: Most modern vehicles have telematic...

7.2AI score
SaveExploits0
OSV
OSV
added 2018/08/17 6:29 p.m.6 views

UBUNTU-CVE-2018-15468

An issue was discovered in Xen through 4.11.x. The DEBUGCTL MSR contains several debugging features, some of which virtualise cleanly, but some do not. In particular, Branch Trace Store is not virtualised by the processor, and software has to be careful to configure it suitably not to lock up the...

6CVSS6.7AI score0.00337EPSS
SaveExploits0References3
Fedora
Fedora
added 2018/08/16 8:8 a.m.16 views

[SECURITY] Fedora 28 Update: units-2.17-5.fc28

Units converts an amount from one unit to another, or tells you what mathematical operation you need to perform to convert from one unit to another. The units program can handle multiplicative scale changes as well as conversions such as Fahrenheit to Celsius...

1.8AI score
SaveExploits0
OSV
OSV
added 2018/08/15 6:29 p.m.7 views

UBUNTU-CVE-2018-14780

An out-of-bounds read issue was discovered in the Yubico-Piv 1.5.0 smartcard driver. The file lib/ykpiv.c contains the following code in the function ykpivfetchobject: % highlight c % ifsw == SWSUCCESS sizet outlen; int offs = ykpivgetlengthdata + 1, &outlen; ifoffs == 0 return YKPIVSIZEERROR;...

4.6CVSS6.6AI score0.00445EPSS
SaveExploits1References5
OSV
OSV
added 2018/08/15 6:29 p.m.6 views

DEBIAN-CVE-2018-14780

An out-of-bounds read issue was discovered in the Yubico-Piv 1.5.0 smartcard driver. The file lib/ykpiv.c contains the following code in the function ykpivfetchobject: % highlight c % ifsw == SWSUCCESS sizet outlen; int offs = ykpivgetlengthdata + 1, &outlen; ifoffs == 0 return YKPIVSIZEERROR;...

4.6CVSS7.2AI score0.00445EPSS
SaveExploits1References1
PyPA
PyPA
added 2018/07/23 8:29 a.m.11 views

PYSEC-2018-62

An issue was discovered in aubio 0.4.6. A SEGV signal can occur in aubiopitchsetunit in pitch/pitch.c, as demonstrated by aubionotes...

8.8CVSS7AI score0.01964EPSS
SaveExploits1References4Affected Software1
OSV
OSV
added 2018/07/23 8:29 a.m.4 views

DEBIAN-CVE-2018-14522

An issue was discovered in aubio 0.4.6. A SEGV signal can occur in aubiopitchsetunit in pitch/pitch.c, as demonstrated by aubionotes...

8.8CVSS7.9AI score0.01964EPSS
SaveExploits1References1
Gitee
Gitee
added 2018/07/21 12:40 p.m.6 views

2016PilotOneClick

This is a collection of utilities and scripts to gain root access on a 2016 model Honda Pilot head unit and simplify the installation of third-party non-Honda apps. The scripts implement a dirtyCOW exploit to gain root access and use a bash script to automate the installation process. The scripts...

7.2AI score
SaveExploits0
Rows per page