Lucene search
+L

7041 matches found

RedHat Linux
RedHat Linux
•added 2019/11/12 8:49 p.m.•15 views

hw: Machine Check Error on Page Size Change (IFU)

A flaw was found in the way Intel CPUs handle inconsistency between, virtual to physical memory address translations in CPU's local cache and system software's Paging structure entries. A privileged guest user may use this flaw to induce a hardware Machine Check Error on the host processor,...

6.5CVSS6.6AI score0.00915EPSS
SaveExploits0References6
RedHat Linux
RedHat Linux
•added 2019/11/12 8:48 p.m.•19 views

hw: Intel GPU Denial Of Service while accessing MMIO in lower power state

A flaw was found in Intel graphics hardware GPU where a local attacker with the ability to issue an ioctl could trigger a hardware level crash if MMIO registers were read while the graphics card was in a low-power state. This creates a denial of service situation and the GPU and connected display...

5.5CVSS6.7AI score0.00646EPSS
SaveExploits0References6
CNVD
CNVD
•added 2019/11/11 12:00 a.m.•22 views

NVIDIA Windows GPU Display Driver Denial of Service Vulnerability (CNVD-2019-40475)

NVIDIA Windows GPU Display Driver is a graphics processor GPU graphics card driver from NVIDIA dedicated to the Windows platform. A denial of service vulnerability exists in the kernel mode layer nvlddmkm.sys of the NVIDIA Windows GPU Display Driver. The vulnerability stems from a program that...

5.5CVSS6.7AI score0.00274EPSS
SaveExploits0References1
CNVD
CNVD
•added 2019/11/11 12:00 a.m.•20 views

NVIDIA Windows GPU Display Driver Null Pointer Dereference Vulnerability

NVIDIA Windows GPU Display Driver is a graphics processor GPU graphics card driver from NVIDIA dedicated to the Windows platform. A null pointer dereference vulnerability exists in the kernel mode layer nvlddmkm.sys handler for DxgkDdiEscape in the NVIDIA Windows GPU Display Driver. An attacker...

7.8CVSS6.7AI score0.00364EPSS
SaveExploits0References1
Tenable Nessus
Tenable Nessus
•added 2019/11/08 12:00 a.m.•31 views

Siemens En100 Improper Authentication

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

10CVSS4.8AI score0.0286EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
•added 2019/11/08 12:00 a.m.•26 views

Siemens En100 Improper Authentication

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

9CVSS5.7AI score0.02113EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
•added 2019/11/08 12:00 a.m.•35 views

Siemens En100 Unspecified Vulnerability

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

7.8CVSS3.5AI score0.03002EPSS
SaveExploits0References6
Tenable Nessus
Tenable Nessus
•added 2019/11/08 12:00 a.m.•21 views

Siemens SIMATIC Compact Field Unit PA Edition PROFINET Interface Detection

Binary data 765350.prm...

7.3AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
•added 2019/11/08 12:00 a.m.•42 views

Siemens Siprotec Unspecified Vulnerability

A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

7.8CVSS3.6AI score0.74497EPSS
SaveExploits7References7
Tenable Nessus
Tenable Nessus
•added 2019/11/08 12:00 a.m.•73 views

EulerOS 2.0 SP5 : libdwarf (EulerOS-SA-2019-2204)

According to the versions of the libdwarf package installed, the EulerOS installation on the remote host is affected by the following vulnerabilities : - dwarfleb.c in libdwarf allows attackers to cause a denial of service SIGSEGV.CVE-2015-8538 - The dwarfdealloc function in libdwarf before...

7.5CVSS6.5AI score0.04379EPSS
SaveExploits7References9
osv_cve
osv_cve
•added 2019/10/28 1:15 p.m.•22 views

CVE-2019-14925

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames,...

6.5CVSS6.6AI score0.0126EPSS
SaveExploits1References2
Positive Technologies
Positive Technologies
•added 2019/10/28 12:00 a.m.•16 views

PT-2019-13872 · Mitsubishi · Me-Rtu

Name of the Vulnerable Software and Affected Versions: Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 INEA ME-RTU devices through 3.0 Description: An issue was discovered that allows an attacker to gain unauthorized access to the RTU due to undocumented hard-coded user passwords for...

10CVSS7.3AI score0.02343EPSS
SaveExploits1References4
Positive Technologies
Positive Technologies
•added 2019/10/28 12:00 a.m.•26 views

PT-2019-13873

Name of the Vulnerable Software and Affected Versions Mitsubishi Electric Europe B.V. ME-RTU devices versions 2.02 and earlier INEA ME-RTU devices versions 3.0 and earlier Description An unauthenticated remote OS Command Injection issue allows an attacker to execute arbitrary commands on the RTU...

10CVSS8.4AI score0.57376EPSS
SaveExploits3References7
Positive Technologies
Positive Technologies
•added 2019/10/28 12:00 a.m.•23 views

PT-2019-13869 · Mitsubishi · Me-Rtu

Name of the Vulnerable Software and Affected Versions: Mitsubishi Electric Europe B.V. ME-RTU devices versions 2.02 and earlier INEA ME-RTU devices versions 3.0 and earlier Description: An unauthenticated remote configuration download issue allows an attacker to download the smartRTU's...

7.5CVSS7.2AI score0.4088EPSS
SaveExploits3References5
Prion
Prion
•added 2019/10/25 6:15 p.m.•27 views

Authentication flaw

Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on an...

5CVSS8.1AI score0.01035EPSS
SaveExploits1References2Affected Software1
Prion
Prion
•added 2019/10/25 6:15 p.m.•33 views

Hardcoded credentials

Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems is configured using hard-coded credentials. These credentials could allow attackers to influence the primary operations of the affected systems, namely...

10CVSS9.5AI score0.02297EPSS
SaveExploits1References2Affected Software1
Cvelist
Cvelist
•added 2019/10/25 5:46 p.m.•73 views

CVE-2019-13553

Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems is configured using hard-coded credentials. These credentials could allow attackers to influence the primary operations of the affected systems, namely...

9.7AI score0.02297EPSS
SaveExploits1References2
Cvelist
Cvelist
•added 2019/10/25 5:43 p.m.•71 views

CVE-2019-13549

Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on an...

7.7AI score0.01035EPSS
SaveExploits1References2
CNVD
CNVD
•added 2019/10/18 12:00 a.m.•19 views

eQ-3 Homematic CCU3 Remote Code Execution Vulnerability (CNVD-2020-14281)

The eQ-3 Homematic CCU3 is a central control unit for smart home systems from eQ-3 Germany. A remote code execution vulnerability exists in the ReGa.runScript method in the eQ-3 Homematic CCU3 using firmware version 3.41.11, which can be exploited by an attacker to execute code and compromise the...

9CVSS8.3AI score0.15555EPSS
SaveExploits1References1
CNVD
CNVD
•added 2019/10/18 12:00 a.m.•22 views

eQ-3 Homematic CCU3 Session Fixation Vulnerability

The eQ-3 Homematic CCU3 is a central control unit for smart home systems from eQ-3 Germany. A session fixation vulnerability exists in the eQ-3 Homematic CCU3 using firmware version 3.41.11, which can be exploited by an attacker to log in and control the system by creating a session ID and sendin...

7.3CVSS6.9AI score0.00824EPSS
SaveExploits1References1
Rows per page