178 matches found
EUVD-2026-36672
A vulnerability was identified in VS Revo RevoUninstaller 2.5.x/2.6.x. The affected element is the function IOCtlHandler in the library RevoDetector.sys of the component IOCTL Handler. Such manipulation leads to heap-based buffer overflow. The attack must be carried out locally. The exploit is...
CVE-2026-12193
A vulnerability was identified in VS Revo RevoUninstaller 2.5.x/2.6.x. The affected element is the function IOCtlHandler in the library RevoDetector.sys of the component IOCTL Handler. Such manipulation leads to heap-based buffer overflow. The attack must be carried out locally. The exploit is...
CVE-2026-12193 VS Revo RevoUninstaller IOCTL RevoDetector.sys IOCtl_Handler heap-based overflow
A vulnerability was identified in VS Revo RevoUninstaller 2.5.x/2.6.x. The affected element is the function IOCtlHandler in the library RevoDetector.sys of the component IOCTL Handler. Such manipulation leads to heap-based buffer overflow. The attack must be carried out locally. The exploit is...
PT-2026-49113
Name of the Vulnerable Software and Affected Versions VS Revo RevoUninstaller versions 2.5.x through 2.6.x Description A heap-based buffer overflow exists in the IOCtl Handler function within the RevoDetector.sys library of the IOCTL Handler component. This issue requires local access to be...
CVE-2026-26191
Fleet is open source device management software. Prior to version 4.81.0, a vulnerability in Fleet's software installer pipeline could allow a crafted software package to execute arbitrary commands as root macOS/Linux or SYSTEM Windows on managed endpoints when an uninstall is triggered. When a...
EUVD-2020-31224
IObit Uninstaller 9.5.0.15 contains an unquoted service path vulnerability in the IObitUnSvr service that allows local attackers to escalate privileges to SYSTEM level. Attackers can place a malicious executable named IObit.exe in the C:\Program Files x86\IObit directory and restart the service t...
CVE-2020-37223
IObit Uninstaller 9.5.0.15 contains an unquoted service path vulnerability in the IObitUnSvr service that allows local attackers to escalate privileges to SYSTEM level. Attackers can place a malicious executable named IObit.exe in the C:\Program Files x86\IObit directory and restart the service t...
CVE-2020-37223 IObit Uninstaller 9.5.0.15 Unquoted Service Path Privilege Escalation
IObit Uninstaller 9.5.0.15 contains an unquoted service path vulnerability in the IObitUnSvr service that allows local attackers to escalate privileges to SYSTEM level. Attackers can place a malicious executable named IObit.exe in the C:\Program Files x86\IObit directory and restart the service t...
CVE-2020-37223 IObit Uninstaller 9.5.0.15 Unquoted Service Path Privilege Escalation
IObit Uninstaller 9.5.0.15 contains an unquoted service path vulnerability in the IObitUnSvr service that allows local attackers to escalate privileges to SYSTEM level. Attackers can place a malicious executable named IObit.exe in the C:\Program Files x86\IObit directory and restart the service t...
CVE-2020-37223
IObit Uninstaller 9.5.0.15 contains an unquoted service path vulnerability in the IObitUnSvr service that allows local attackers to escalate privileges to SYSTEM level. Attackers can place a malicious executable named IObit.exe in the C:\Program Files x86\IObit directory and restart the service t...
CVE-2020-37223
CVE-2020-37223 concerns IObit Uninstaller 9.5.0.15, where an unquoted service path in the IObitUnSvr service enables local privilege escalation to SYSTEM. The attack scenario described: an attacker places a malicious executable named IObit.exe in C:\Program Files (x86)\IObit and restarts the IObi...
IObit Uninstaller 代码问题漏洞
IObit Uninstaller is a Windows software tool designed for forced uninstallation by IObit Corporation. Version 9.5.0.15 of IObit Uninstaller has a code vulnerability. This vulnerability stems from an issue with unreferenced service paths within the IObitUnSvr service, which may allow local attacke...
PT-2026-40624
IObit Uninstaller 9.5.0.15 contains an unquoted service path vulnerability in the IObitUnSvr service that allows local attackers to escalate privileges to SYSTEM level. Attackers can place a malicious executable named IObit.exe in the C:Program Files x86IObit directory and restart the service to...
Command Injection
Overview Affected versions of this package are vulnerable to Command Injection via the software installer pipeline that generates uninstall shell scripts without sanitization. An attacker can execute arbitrary system commands with elevated privileges by crafting malicious software package metadat...
EUVD-2026-16160
The VSL privileged helper does utilize NSXPC for IPC. The implementation of the "shouldAcceptNewConnection" function, which is used by the NSXPC framework to validate if a client should be allowed to connect to the XPC listener, does not validate clients at all. This means that any process can...
CVE-2026-24068
The VSL privileged helper does utilize NSXPC for IPC. The implementation of the "shouldAcceptNewConnection" function, which is used by the NSXPC framework to validate if a client should be allowed to connect to the XPC listener, does not validate clients at all. This means that any process can...
CVE-2026-24068
The VSL privileged helper does utilize NSXPC for IPC. The implementation of the "shouldAcceptNewConnection" function, which is used by the NSXPC framework to validate if a client should be allowed to connect to the XPC listener, does not validate clients at all. This means that any process can...
CVE-2026-24068 Missing XPC Client & NSXPC endpoint validation leads to privilege escalation in Vienna Assistant (MacOS) - Vienna Symphonic Library
The VSL privileged helper does utilize NSXPC for IPC. The implementation of the "shouldAcceptNewConnection" function, which is used by the NSXPC framework to validate if a client should be allowed to connect to the XPC listener, does not validate clients at all. This means that any process can...
CVE-2026-24068
The CVE-2026-24068 issue affects Vienna Assistant (MacOS) via the VSL privileged helper that uses NSXPC for IPC. The core problem is that shouldAcceptNewConnection does not validate clients, allowing any process to connect and invoke HelperToolProtocol functions, notably writeReceiptFile and runU...
PT-2026-28337
Name of the Vulnerable Software and Affected Versions Vienna Assistant affected versions not specified Description The Vienna Assistant privileged helper utilizes NSXPC for Inter-Process Communication IPC. The implementation of the shouldAcceptNewConnection function, used by the NSXPC framework t...