2175 matches found
Ansys SpaceClaim 缓冲区错误漏洞
Ansys SpaceClaim is a solid modeling CAD software from Ansys Corporation. A buffer error vulnerability exists in Ansys SpaceClaim 2022 R1, which stems from a specific flaw in the parsing of XB files, where a pointer is not properly initialized before being accessed, and can be exploited by an...
Siemens Simcenter Femap and Parasolid Uninitialized Pointer Access Vulnerability
Parasolid is a 3D geometric modeling tool that supports a variety of techniques, including solid modeling, direct editing, and free-form/sheet modeling.Simcenter Femap is an advanced simulation application for creating, editing, and examining finite element models of complex products or...
Siemens Simcenter Femap and Parasolid Uninitialized Pointer Access Vulnerability (CNVD-2022-62987)
Parasolid is a 3D geometric modeling tool that supports a variety of techniques, including solid modeling, direct editing, and free-form/sheet modeling.Simcenter Femap is an advanced simulation application for creating, editing, and examining finite element models of complex products or...
(0Day) Ansys SpaceClaim X_B File Parsing Uninitialized Pointer Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Ansys SpaceClaim. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XB...
PT-2022-25442 · Ansys · Ansys Spaceclaim
Name of the Vulnerable Software and Affected Versions: Ansys SpaceClaim version 2022 R1 Description: This issue allows remote attackers to execute arbitrary code on affected installations. User interaction is required, where the target must visit a malicious page or open a malicious file. The fla...
(0Day) Ansys SpaceClaim X_B File Parsing Uninitialized Pointer Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Ansys SpaceClaim. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XB...
PT-2022-25446 · Ansys · Ansys Spaceclaim
Name of the Vulnerable Software and Affected Versions: Ansys SpaceClaim version 2022 R1 Description: This issue allows remote attackers to execute arbitrary code on affected installations. User interaction is required, where the target must visit a malicious page or open a malicious file. The fla...
The vulnerability of the QEMU hardware emulation software, related to access to an uninitialized pointer, allows a hacker to trigger a service failure.
The vulnerability of the QEMU hardware emulation software is related to access to an uninitialized pointer. Exploiting this vulnerability can allow a malicious actor to cause a system failure...
CVE-2022-39146
A vulnerability has been identified in Parasolid V33.1 All versions = V33.1.262 = V35.0.161 V35.0.164, Simcenter Femap V2022.1 All versions V2022.1.3, Simcenter Femap V2022.2 All versions V2022.2.2. The affected application is vulnerable to uninitialized pointer access while parsing specially...
CVE-2022-39146
A vulnerability has been identified in Parasolid V33.1 All versions = V33.1.262 = V35.0.161 V35.0.164, Simcenter Femap V2022.1 All versions V2022.1.3, Simcenter Femap V2022.2 All versions V2022.2.2. The affected application is vulnerable to uninitialized pointer access while parsing specially...
CVE-2022-39147
A vulnerability has been identified in Parasolid V33.1 All versions = V33.1.262 = V35.0.161 V35.0.164, Simcenter Femap V2022.1 All versions V2022.1.3, Simcenter Femap V2022.2 All versions V2022.2.2. The affected application is vulnerable to uninitialized pointer access while parsing specially...
CVE-2022-39147
A vulnerability has been identified in Parasolid V33.1 All versions = V33.1.262 = V35.0.161 V35.0.164, Simcenter Femap V2022.1 All versions V2022.1.3, Simcenter Femap V2022.2 All versions V2022.2.2. The affected application is vulnerable to uninitialized pointer access while parsing specially...
CVE-2022-39146
A vulnerability has been identified in Parasolid V33.1 All versions = V33.1.262 = V35.0.161 V35.0.164, Simcenter Femap V2022.1 All versions V2022.1.3, Simcenter Femap V2022.2 All versions V2022.2.2. The affected application is vulnerable to uninitialized pointer access while parsing specially...
Design/Logic Flaw
A vulnerability has been identified in Parasolid V33.1 All versions = V33.1.262 = V35.0.161 V35.0.164, Simcenter Femap V2022.1 All versions V2022.1.3, Simcenter Femap V2022.2 All versions V2022.2.2. The affected application is vulnerable to uninitialized pointer access while parsing specially...
Design/Logic Flaw
A vulnerability has been identified in Parasolid V33.1 All versions = V33.1.262 = V35.0.161 V35.0.164, Simcenter Femap V2022.1 All versions V2022.1.3, Simcenter Femap V2022.2 All versions V2022.2.2. The affected application is vulnerable to uninitialized pointer access while parsing specially...
CVE-2022-39147
Summary (CVE-2022-39147) : Siemens Parasolid and Simcenter Femap are affected by an uninitialized pointer access vulnerability while parsing X_T files, enabling code execution in the context of the current process. Affected products/versions include Parasolid V33.1 (pre-262 and 262–263 ranges), V...
CVE-2022-39146
The CVE-2022-39146 entry affects Siemens Parasolid and Simcenter Femap: uninitialized pointer access when parsing X_T files. Affected Parasolid versions include V33.1 (all < V33.1.262 and V33.1.262–263), V34.0 (< V34.0.252), V34.1 (< V34.1.242), and V35.0 (= V35.0.161 < V35.0.164). Af...
CVE-2022-39146
A vulnerability has been identified in Parasolid V33.1 All versions = V33.1.262 = V35.0.161 V35.0.164, Simcenter Femap V2022.1 All versions V2022.1.3, Simcenter Femap V2022.2 All versions V2022.2.2. The affected application is vulnerable to uninitialized pointer access while parsing specially...
Siemens Parasolid 缓冲区错误漏洞
Parasolid is a 3D geometric modeling tool that supports a variety of techniques, including solid modeling, direct editing, and free-form/sheet modeling.Simcenter Femap is an advanced simulation application for creating, editing, and examining finite element models of complex products or...
Siemens Parasolid 缓冲区错误漏洞
Parasolid is a 3D geometric modeling tool that supports a variety of techniques, including solid modeling, direct editing, and free-form/sheet modeling.Simcenter Femap is an advanced simulation application for creating, editing, and examining finite element models of complex products or...