CVE-2021-37292
An Access Control vulnerability exists in KevinLAB Inc Building Energy Management System 4ST BEMS 1.0.0 due to an undocumented backdoor account. A malicious user can log in using the backdor account with admin highest privileges and obtain system control...
CVE-2021-37292
CVE-2021-37292 affects KevinLAB Building Energy Management System 4ST BEMS 1.0.0. The NUCLEI template confirms an undocumented backdoor account with admin-level privileges enables login and full remote control, bypassing authentication. Impact is full system control and remote administration. Mit...
PT-2022-10647
Name of the Vulnerable Software and Affected Versions KevinLAB Inc Building Energy Management System 4ST BEMS version 1.0.0 Description An Access Control issue exists due to an undocumented backdoor account. A malicious user can log in using this backdoor account with admin highest privileges and...
Hamas-linked Hackers Targeting High-Ranking Israelis Using 'Catfish' Lures
A threat actor with affiliations to the cyber warfare division of Hamas has been linked to an "elaborate campaign" targeting high-profile Israeli individuals employed in sensitive defense, law enforcement, and emergency services organizations. "The campaign operators use sophisticated social...
PT-2022-2956 · Mitel · Mitel 6900 Series Ip Phones +1
Name of the Vulnerable Software and Affected Versions: Mitel 6800 Series SIP Phones versions 5.1 SP8 5.1.0.8016 and earlier Mitel 6800 Series SIP Phones versions 6.0 6.0.0.368 through 6.1 HF4 6.1.0.165 Mitel 6900 Series SIP Phones versions 5.1 SP8 5.1.0.8016 and earlier Mitel 6900 Series SIP Phon...
Moxa MXView Series Web Application authentication bypass vulnerability
Summary An authentication bypass vulnerability exists in the Web Application functionality of Moxa MXView Series 3.2.4. A specially-crafted HTTP request can lead to unauthorized access. An attacker can send an HTTP request to trigger this vulnerability. Tested Versions Moxa MXView Series 3.2.4...
Rockwell Automation Micrologix Improper Access Control (CVE-2017-14472)
An exploitable access control vulnerability exists in the data, program, and function file permissions functionality of Allen Bradley Micrologix 1400 Series B FRN 21.2 and before. A specially crafted packet can cause a read or write operation resulting in disclosure of sensitive information,...
CVE-2021-36339
The Dell EMC Virtual Appliances before 9.2.2.2 contain undocumented user accounts. A local malicious user may potentially exploit this vulnerability to get privileged access to the virtual appliance...
CVE-2021-36339
The Dell EMC Virtual Appliances before 9.2.2.2 contain undocumented user accounts. A local malicious user may potentially exploit this vulnerability to get privileged access to the virtual appliance...
Design/Logic Flaw
The Dell EMC Virtual Appliances before 9.2.2.2 contain undocumented user accounts. A local malicious user may potentially exploit this vulnerability to get privileged access to the virtual appliance...
CVE-2021-36339
The CVE-2021-36339 issue affects Dell EMC Virtual Appliances prior to version 9.2.2.2, where undocumented user accounts exist. This enables a local attacker with access to the appliance to potentially obtain privileged access. The vulnerability is rooted in the presence of hidden accounts rather ...
CVE-2021-36339
The Dell EMC Virtual Appliances before 9.2.2.2 contain undocumented user accounts. A local malicious user may potentially exploit this vulnerability to get privileged access to the virtual appliance...
CVE-2021-45033
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C All versions V16.20, CP-8000 MASTER MODULE WITH I/O -40/+70°C All versions V16.20, CP-8021 MASTER MODULE All versions V16.20, CP-8022 MASTER MODULE WITH GPRS All versions V16.20. An undocumented debug port uses...
CVE-2021-45033
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C All versions V16.20, CP-8000 MASTER MODULE WITH I/O -40/+70°C All versions V16.20, CP-8021 MASTER MODULE All versions V16.20, CP-8022 MASTER MODULE WITH GPRS All versions V16.20. An undocumented debug port uses...
Hardcoded credentials
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C All versions V16.20, CP-8000 MASTER MODULE WITH I/O -40/+70°C All versions V16.20, CP-8021 MASTER MODULE All versions V16.20, CP-8022 MASTER MODULE WITH GPRS All versions V16.20. An undocumented debug port uses...
CVE-2021-43987
An additional, nondocumented administrative account exists in mySCADA myPRO Versions 8.20.0 and prior that is not exposed through the web interface, which cannot be deleted or changed through the regular web interface...
Design/Logic Flaw
An additional, nondocumented administrative account exists in mySCADA myPRO Versions 8.20.0 and prior that is not exposed through the web interface, which cannot be deleted or changed through the regular web interface...
Unspecified vulnerability in mySCADA myPRO (CNVD-2021-102830)
mySCADA myPRO is an HMI/SCADA system designed primarily for the visualization and control of industrial processes. A security vulnerability exists in mySCADA myPRO, which can be exploited by an attacker to cause an additional, undocumented administrative account to exist in the affected product,...
mySCADA myPRO 安全漏洞
mySCADA myPRO is an HMI/SCADA system designed primarily for the visualization and control of industrial processes. A security vulnerability exists in mySCADA myPRO, which can be exploited by an attacker to cause an additional, undocumented administrative account to exist in the affected product,...
SingleNativeTokenExitV2 only returns single output token
Handle cmichel Vulnerability details The SingleNativeTokenExitV2.exit function performs a list of arbitrary user-defined swaps on the exited token basket. These could result in many different final "output" tokens ending up in the contract after the swaps. However, the contract assumes that there...