11472 matches found
PT-2022-7119
Name of the Vulnerable Software and Affected Versions OpenImageIO version 2.4.7.1 Description A denial of service issue exists in the FitsOutput::close functionality of OpenImageIO, related to uncontrolled recursion. This can be triggered by a specially crafted ImageOutput Object, allowing a remo...
Mitsubishi Electric MELSEC-Q Series and MELSEC-L Series CPU Modules Uncontrolled Resource Consumption (CVE-2019-13555)
In Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU: serial number 21081 and prior, Q04/06/13/26UDPVCPU: serial number 21081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 21081 and prior, MELSEC-L Series L02/06/26CPU, L26CPU-BT: serial number 21101 and prior,...
Mitsubishi Electric MELSEC-Q Series Ethernet Module Uncontrolled Resource Consumption (CVE-2019-10977)
In Mitsubishi Electric MELSEC-Q series Ethernet module QJ71E71-100 serial number 20121 and prior, an attacker could send crafted TCP packets against the FTP service, forcing the target devices to enter an error mode and cause a denial-of-service condition. This plugin only works with Tenable.ot...
Siemens PROFINET Devices Uncontrolled Resource Consumption (CVE-2019-10936)
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200SP Open Controller CPU 1515SP P...
Siemens PROFINET-IO Stack Uncontrolled Resource Consumption (CVE-2019-13946)
Profinet-IO PNIO stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable...
Siemens SIMATIC S7-300 CPUs and SINUMERIK Controller over Profinet Uncontrolled Resource Consumption (CVE-2019-18336)
A vulnerability has been identified in SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions V3.X.17, SIMATIC TDC CP51M1 All versions V1.1.8, SIMATIC TDC CPU555 All versions V1.1.1, SINUMERIK 840D sl All versions V4.8.6, SINUMERIK 840D sl All versions V4.94. Speciall...
Mitsubishi Electric MELSEC-Q Series PLCs Uncontrolled Resource Consumption (CVE-2019-6535)
Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. A remote attacker can send specific bytes over Port 5007 that will result in an Ethernet...
Mitsubishi Electric MELSEC iQ-R Series Uncontrolled Resource Consumption (CVE-2020-5668)
Uncontrolled resource consumption vulnerability in MELSEC iQ-R Series modules R00/01/02CPU firmware version '19' and earlier, R04/08/16/32/120 EN CPU firmware version '51' and earlier, R08/16/32/120SFCPU firmware version '22' and earlier, R08/16/32/120PCPU firmware version '25' and earlier,...
Mitsubishi Electric MELSEC iQ-R Series C Controller Module Uncontrolled Resource Consumption (CVE-2021-20600)
Uncontrolled resource consumption in MELSEC iQ-R series C Controller Module R12CCPU-V all versions allows a remote unauthenticated attacker to cause a denial-of-service DoS condition by sending a large number of packets in a short time while the module starting up. System reset is required for...
Siemens SIMATIC S7-300 CPUs and SINUMERIK Controller Uncontrolled Resource Consumption (CVE-2020-15783)
A vulnerability has been identified in SIMATIC S7-300 CPU family incl. related ET200 CPUs and SIPLUS variants All versions, SIMATIC TDC CPU555 All versions, SINUMERIK 840D sl All versions. Sending multiple specially crafted packets to the affected devices could cause a Denial-of-Service on port...
Mitsubishi Electric MELSEC iQ-R Series Uncontrolled Resource Consumption (CVE-2020-5666)
Uncontrolled resource consumption vulnerability in MELSEC iQ-R Series CPU Modules R00/01/02CPU Firmware versions from '05' to '19' and R04/08/16/32/120ENCPU Firmware versions from '35' to '51' allows a remote attacker to cause an error in a CPU unit via a specially crafted HTTP packet, which may...
The vulnerability of the Adobe Creative Cloud Desktop Application’s graphic editor app relates to an uncontrolled search path element, allowing attackers to escalate their privileges.
The vulnerability of the Adobe Creative Cloud Desktop Application’s graphic editor app relates to an uncontrolled search path element. Exploiting this vulnerability can allow attackers to enhance their privileges within the system using a specially crafted file...
Mitsubishi Electric MELSEC iQ-R, Q and L Series Uncontrolled Resource Consumption (CVE-2020-5652)
Uncontrolled resource consumption vulnerability in Ethernet Port on MELSEC iQ-R, Q and L series CPU modules R 00/01/02 CPU firmware versions '20' and earlier, R 04/08/16/32/120 EN CPU firmware versions '52' and earlier, R 08/16/32/120 SFCPU firmware versions '22' and earlier, R 08/16/32/120 PCPU...
Mitsubishi Electric MELSEC iQ-R Series Uncontrolled Resource Consumption (CVE-2020-16850)
Mitsubishi MELSEC iQ-R Series PLCs with firmware 49 allow an unauthenticated attacker to halt the industrial process by sending a crafted packet over the network. This denial of service attack exposes Improper Input Validation. After halting, physical access to the PLC is required in order to...
Siemens SIMATIC S7 Uncontrolled Resource Consumption (CVE-2019-13940)
A vulnerability has been identified in SIMATIC ET 200pro IM154-8 PN/DP CPU All versions V3.X.17, SIMATIC ET 200pro IM154-8F PN/DP CPU All versions V3.X.17, SIMATIC ET 200pro IM154-8FX PN/DP CPU All versions V3.X.17, SIMATIC ET 200S IM151-8 PN/DP CPU All versions V3.X.17, SIMATIC ET 200S IM151-8F...
Siemens SIMATIC S7-200 SMART CPU Family Uncontrolled Resource Consumption (CVE-2020-7584)
A vulnerability has been identified in SIMATIC S7-200 SMART CPU family All versions = V2.2 = V2.2 V2.5.1. Affected devices do not properly handle large numbers of new incomming connections and could crash under certain circumstances. An attacker may leverage this to cause a Denial-of-Service...
Mitsubishi Electric MELSEC iQ-R Series Uncontrolled Resource Consumption (CVE-2021-20591)
Uncontrolled Resource Consumption vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules R00/01/02CPU all versions, R04/08/16/32/120ENCPU all versions, R08/16/32/120SFCPU all versions, R08/16/32/120PCPU all versions, R08/16/32/120PSFCPU all versions allows a remote unauthenticated...
Mitsubishi Electric MELSEC Uncontrolled Resource Consumption (CVE-2020-5527)
When MELSOFT transmission port UDP/IP of Mitsubishi Electric MELSEC iQ-R series all versions, MELSEC iQ-F series all versions, MELSEC Q series all versions, MELSEC L series all versions, and MELSEC F series all versions receives massive amount of data via unspecified vectors, resource consumption...
Siemens PROFINET DCP Uncontrolled Resource Consumption (CVE-2017-2680)
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment Layer 2. Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. This plugin only works with Tenable.ot. Please visit...
Apache ActiveMQ Artemis Uncontrolled Resource Consumption (DoS)
In Apache ActiveMQ Artemis prior to 2.20.0 or 2.19.1, an attacker could partially disrupt availability DoS through uncontrolled resource consumption of memory...