Lucene search
+L

1023 matches found

Github Security Blog
Github Security Blog
added 2020/03/16 10:46 p.m.112 views

Insufficient Nonce Validation in Eclipse Milo Client

Impact Credential replay affecting those connected to a server when all 3 of the following conditions are met: - SecurityPolicy is None - using username/password or X509-based authentication - the server has a defect causing it to send null/empty or zeroed nonces Patches The problem has been...

7.4CVSS0.5AI score0.01043EPSS
SaveExploits0References6Affected Software1
OSV
OSV
added 2020/03/16 4:15 p.m.12 views

CVE-2019-19135

In OPC Foundation OPC UA .NET Standard codebase 1.4.357.28, servers do not create sufficiently random numbers in OPCFoundation.NetStandard.Opc.Ua before 1.4.359.31, which allows man in the middle attackers to reuse encrypted user credentials sent over the network...

7.4CVSS6.8AI score
SaveExploits0References2
CVE
CVE
added 2020/03/16 3:47 p.m.87 views

CVE-2019-19135

CVE-2019-19135 concerns the OPC Foundation OPC UA .NET Standard stack (version 1.4.357.28) where servers do not generate sufficiently random numbers before 1.4.359.31. This weakness can allow a remote attacker to perform a MITM and reuse encrypted user credentials sent over the network. Public do...

7.4CVSS7.3AI score0.01043EPSS
SaveExploits0References2Affected Software2
ThreatPost
ThreatPost
added 2020/01/22 11:50 p.m.74 views

Pwn2Own Miami Contestants Haul in $180K for Hacking ICS Equipment

The very first Pwn2Own hacking competition that exclusively focuses on the industrial control systems ICS has kicked off in Miami. So far, a total of $180,000 has been awarded for pwning five different products. The contest hosts at Trend Micro’s Zero Day initiative ZDI have allocated more than...

1.9AI score
SaveExploits0References6
Openbugbounty
Openbugbounty
added 2020/01/10 2:22 p.m.6 views

ua-magazine.com Cross Site Scripting vulnerability

Open Bug Bounty ID: OBB-1064890 Security Researcher geeknik Helped patch 8958 vulnerabilities Received 8 Coordinated Disclosure badges Received 21 recommendations , a holder of 8 badges for responsible and coordinated disclosure, found a security vulnerability affecting ua-magazine.com website an...

0.2AI score
SaveExploits0
Tenable Nessus
Tenable Nessus
added 2019/11/08 12:00 a.m.31 views

Siemens Simatic Improper Input Validation

A vulnerability has been identified in SIMATIC CP 443-1 OPC UA All versions, SIMATIC CP443-1 OPC UA incl. SIPLUS NET variants All versions, SIMATIC ET 200 Open Controller CPU 1515SP PC2 incl. SIPLUS variants All versions = V7.1 = V2.5 V2.6.1, SIMATIC S7-1500 Software Controller All versions betwe...

7.8CVSS1.7AI score0.01646EPSS
SaveExploits0References2
OSV
OSV
added 2019/10/10 8:15 p.m.8 views

CVE-2019-11527

An issue was discovered in Softing uaGate SI 1.60.01. A CGI script is vulnerable to command injection with a maliciously crafted url parameter...

8.8CVSS7.3AI score0.03486EPSS
SaveExploits1References1
Openbugbounty
Openbugbounty
added 2019/10/04 5:07 p.m.12 views

hotel19.ua Cross Site Scripting vulnerability

Security Researcher geeknik Helped patch 8635 vulnerabilities Received 8 Coordinated Disclosure badges Received 20 recommendations , a holder of 8 badges for responsible and coordinated disclosure, found a security vulnerability affecting hotel19.ua website and its users. Following coordinated an...

0.2AI score
SaveExploits0
NVD
NVD
added 2019/09/17 7:15 p.m.31 views

CVE-2019-13542

3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition...

6.5CVSS6.4AI score0.01365EPSS
SaveExploits0References1
Prion
Prion
added 2019/09/17 7:15 p.m.19 views

Null pointer dereference

3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition...

4CVSS6.3AI score0.01365EPSS
SaveExploits0References1Affected Software10
CVE
CVE
added 2019/09/17 6:56 p.m.109 views

CVE-2019-13542

CVE-2019-13542 affects 3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server (versions 3.5.11.0 to 3.5.15.0). The vulnerability is a NULL pointer dereference triggered by crafted requests from a trusted OPC UA client, potentially causing a denial-of-service condition. Public sources (CISA ICS...

6.5CVSS6.3AI score0.01365EPSS
SaveExploits0References1Affected Software10
Cvelist
Cvelist
added 2019/09/17 6:56 p.m.39 views

CVE-2019-13542

3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition...

6.4AI score0.01365EPSS
SaveExploits0References1
ICS
ICS
added 2019/09/12 12:00 a.m.113 views

3S-Smart Software Solutions GmbH CODESYS Control V3 OPC UA Server

1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: 3S-Smart Software Solutions GmbH Equipment: CODESYS Control V3 OPC UA Server Vulnerability: NULL Pointer Reference 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a...

6.5CVSS6.6AI score0.01365EPSS
SaveExploits0References4
ICS
ICS
added 2019/09/10 12:00 a.m.536 views

ICSA-19-253-03_Siemens Industrial Products (Update P)

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Industrial Products Vulnerabilities: Excessive Data Query Operations in a Large Data Table, Integer Overflow or Wraparound, Uncontrolled Resource Consumption 2. UPDATE INFORMATION...

8.6AI score
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2019/05/08 12:00 a.m.10 views

Siemens CP 443-1 OPC UA Communications Adapter Detection

Binary data 750290.prm...

7.3AI score
SaveExploits0
Cvelist
Cvelist
added 2019/04/17 1:40 p.m.34 views

CVE-2019-6575

A vulnerability has been identified in SIMATIC CP 443-1 OPC UA All versions, SIMATIC ET 200SP Open Controller CPU 1515SP PC2 incl. SIPLUS variants All versions = V2.5 V2.6.1, SIMATIC S7-1500 Software Controller All versions between V2.5 including and V2.7 excluding, SIMATIC WinCC OA All versions...

7.5AI score0.01646EPSS
SaveExploits0References1
CVE
CVE
added 2019/04/17 1:40 p.m.112 views

CVE-2019-6575

CVE-2019-6575 affects Siemens industrial products using OPC UA, including SIMATIC CP443-1 OPC UA, ET 200 Open Controller CPU 1515SP PC2, HMI Outdoor Panels (7"/15"), HMI Comfort Panels (4"–22"), KTP Mobile Panels, IPC DiagMonitor, NET PC Software, RF188C, RF600R, S7‑1500 family, WinCC OA/Runtime,...

7.8CVSS7.4AI score0.01646EPSS
SaveExploits0References1Affected Software1
CNVD
CNVD
added 2019/04/10 12:00 a.m.12 views

Siemens Industrial Products with OPC UA Denial of Service Vulnerability

Siemens is a leading global technology company providing solutions to customers in the areas of power generation and transmission and distribution, infrastructure, industrial automation, drives and software through innovations in electrification, automation and digitalization. A denial of service...

7.8CVSS6.7AI score0.01646EPSS
SaveExploits0References1
ICS
ICS
added 2019/04/09 12:00 a.m.254 views

Siemens Industrial Products with OPC UA (Update H)

1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SIMATIC, SINEC-NMS, SINEMA, SINEMURIK Industrial Control Products with OPC UA Vulnerability: Uncaught Exception 2. UPDATE INFORMATION This updated advisory is a follow-up to the...

7.8CVSS7.9AI score0.01646EPSS
SaveExploits0References8
Positive Technologies
Positive Technologies
added 2019/04/09 12:00 a.m.13 views

PT-2019-2034 · Siemens · Simatic Hmi Comfort Outdoor Panels 7" & 15" +16

Name of the Vulnerable Software and Affected Versions: SIMATIC CP 443-1 OPC UA versions prior to the fixed version SIMATIC ET 200SP Open Controller CPU 1515SP PC2 versions prior to V2.7 SIMATIC HMI Comfort Outdoor Panels 7" & 15" versions prior to V15.1 Upd 4 SIMATIC HMI Comfort Panels 4" - 22"...

7.8CVSS7.5AI score0.01646EPSS
SaveExploits0References3
Rows per page