77 matches found
Mitsubishi Electric Multiple Factory Automation Products (Update D)
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: GOT2000 compatible HMI software, CC-Link IE TSN Industrial Managed Switch, MELSEC iQ-R Series OPC UA Server Module Vulnerabilities: Infinite Loop, OS Command Injection 2...
Mitsubishi Electric FA Engineering Software (Update C)
1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: GX Works3, MX OPC UA Module Configurator-R Vulnerabilities: Cleartext Storage of Sensitive Information, Use of Hard-coded Password, Insufficiently Protected Credentials,...
CVE-2022-25164
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result,...
Information disclosure
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result,...
CVE-2022-25164
CVE-2022-25164 is a cleartext storage vulnerability affecting Mitsubishi Electric GX Works3 (versions 1.000A–1.095Z) and MX OPC UA Module Configurator-R (1.08J and earlier). Root cause: sensitive data stored in cleartext, enabling remote, unauthenticated disclosure and potential access to MELSEC ...
Mitsubishi Electric Multiple Factory Automation Products (Update B)
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: GOT2000 compatible HMI software, CC-Link IE TSN Industrial Managed Switch, MELSEC iQ-R Series OPC UA Server Module Vulnerabilities: Infinite Loop, OS Command Injection 2...
PT-2022-37228 · Git +1 · Open62541
Name of the Vulnerable Software and Affected Versions: No specific software or versions are mentioned in the provided description. Description: A heap-use-after-free READ 4 crash has been reported. The crash occurs in the UA Server networkCallback function and involves the fuzz binary message.cc...
CVE-2022-33916
OPC UA .NET Standard Reference Server 1.04.368 allows a remote attacker to cause the application to access sensitive information...
CVE-2021-40872
An issue was discovered in Softing Industrial Automation uaToolkit Embedded before 1.40. Remote attackers to cause a denial of service DoS or login as an anonymous user bypassing security checks by sending crafted messages to a OPC/UA server. The server process may crash unexpectedly because of a...
CVE-2021-40872
An issue was discovered in Softing Industrial Automation uaToolkit Embedded before 1.40. Remote attackers to cause a denial of service DoS or login as an anonymous user bypassing security checks by sending crafted messages to a OPC/UA server. The server process may crash unexpectedly because of a...
Design/Logic Flaw
An issue was discovered in Softing Industrial Automation uaToolkit Embedded before 1.40. Remote attackers to cause a denial of service DoS or login as an anonymous user bypassing security checks by sending crafted messages to a OPC/UA server. The server process may crash unexpectedly because of a...
CVE-2021-40872
An issue was discovered in Softing Industrial Automation uaToolkit Embedded before 1.40. Remote attackers to cause a denial of service DoS or login as an anonymous user bypassing security checks by sending crafted messages to a OPC/UA server. The server process may crash unexpectedly because of a...
CVE-2021-40872
The CVE-2021-40872 issue affects Softing Industrial Automation uaToolkit Embedded prior to version 1.40. Affected component: the OPC/UA server implemented by uaToolkit Embedded. Root cause: invalid type cast leading to server process crash on crafted messages. Impact: remote attacker can cause a ...
CVE-2021-34594
TwinCAT OPC UA Server in TF6100 and TS6100 in product versions before 4.3.48.0 or with TcOpcUaServer versions below 3.2.0.194 are prone to a relative path traversal that allow administrators to create or delete any files on the system...
Path traversal
TwinCAT OPC UA Server in TF6100 and TS6100 in product versions before 4.3.48.0 or with TcOpcUaServer versions below 3.2.0.194 are prone to a relative path traversal that allow administrators to create or delete any files on the system...
CVE-2021-34594
The CVE-2021-34594 affects Beckhoff TwinCAT OPC UA Server (TF6100/TS6100) prior to 4.3.48.0 or TcOpcUaServer prior to 3.2.0.194. It allows a relative path traversal that can create or delete arbitrary files on the system. Impact per the NVD metadata: integrity and availability HIGH, confidentiali...
CVE-2021-34594 Beckhoff: Relative path traversal vulnerability through TwinCAT OPC UA Server
TwinCAT OPC UA Server in TF6100 and TS6100 in product versions before 4.3.48.0 or with TcOpcUaServer versions below 3.2.0.194 are prone to a relative path traversal that allow administrators to create or delete any files on the system...
PTC OPC UA Server Multiple vulnerabilities
Binary data ptcopcuamultivulns.nbin...
Design/Logic Flaw
TwinCAT OPC UA Server in versions up to 2.3.0.12 and IPC Diagnostics UA Server in versions up to 3.1.0.1 from Beckhoff Automation GmbH & Co. KG are vulnerable to denial of service attacks. The attacker needs to send several specifically crafted requests to the running OPC UA server. After some of...
CVE-2020-12526 BECKHOFF: DoS-Vulnerability for TwinCAT OPC UA Server and IPC Diagnostics UA Server
TwinCAT OPC UA Server in versions up to 2.3.0.12 and IPC Diagnostics UA Server in versions up to 3.1.0.1 from Beckhoff Automation GmbH & Co. KG are vulnerable to denial of service attacks. The attacker needs to send several specifically crafted requests to the running OPC UA server. After some of...