added 2020/06/29 2:15 p.m.6 views

CVE-2020-12048

Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption e.g., TLS/SSL when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker wi...

7.5CVSS5.8AI score0.00452EPSS
SaveExploits0References1
OSV
OSV
added 2020/06/29 2:15 p.m.8 views

CVE-2020-12036

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

7.5CVSS5.8AI score0.00496EPSS
SaveExploits0References1
NVD
NVD
added 2020/06/29 2:15 p.m.34 views

CVE-2020-12037

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

7.5CVSS0.00483EPSS
SaveExploits0References2
NVD
NVD
added 2020/06/29 2:15 p.m.36 views

CVE-2020-12048

Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption e.g., TLS/SSL when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker wi...

7.5CVSS0.00452EPSS
SaveExploits0References1
OSV
OSV
added 2020/06/29 2:15 p.m.10 views

CVE-2019-18256

BIOTRONIK CardioMessenger II, The affected products use individual per-device credentials that are stored in a recoverable format. An attacker with physical access to the CardioMessenger can use these credentials for network authentication and decryption of local data in transit...

4.6CVSS5.8AI score0.00359EPSS
SaveExploits0References1
Prion
Prion
added 2020/06/29 2:15 p.m.25 views

Design/Logic Flaw

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

5CVSS7.4AI score0.00496EPSS
SaveExploits0References1Affected Software1
Prion
Prion
added 2020/06/29 2:15 p.m.25 views

Design/Logic Flaw

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

5CVSS7.4AI score0.00483EPSS
SaveExploits0References2Affected Software1
Prion
Prion
added 2020/06/29 2:15 p.m.27 views

Design/Logic Flaw

Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption e.g., TLS/SSL when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker wi...

5CVSS7.4AI score0.00452EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:56 p.m.39 views

CVE-2019-18256

BIOTRONIK CardioMessenger II, The affected products use individual per-device credentials that are stored in a recoverable format. An attacker with physical access to the CardioMessenger can use these credentials for network authentication and decryption of local data in transit...

4.7AI score0.00359EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2020/06/29 1:49 p.m.41 views

CVE-2020-12036

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

7.4AI score0.00496EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2020/06/29 1:49 p.m.30 views

CVE-2020-12037

Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption e.g., TLS/SSL when configured to send treatment data to a PDMS Patient Data Management System or an EMR Electronic Medical Record system. An attacker could observe...

7.4AI score0.00483EPSS
SaveExploits0References1
CVE
CVE
added 2020/06/29 1:48 p.m.59 views

CVE-2020-12048

CVE-2020-12048 affects Baxter’s Phoenix Hemodialysis Delivery System software versions 3.36 and 3.40. The vulnerability is cleartext transmission of sensitive data (CWE-319): the system does not support data-in-transit encryption (e.g., TLS/SSL) when sending treatment and prescription data over t...

7.5CVSS7.4AI score0.00452EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2020/06/29 1:48 p.m.39 views

CVE-2020-12048

Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption e.g., TLS/SSL when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker wi...

7.4AI score0.00452EPSS
SaveExploits0References1
OSV
OSV
added 2020/06/23 8:15 p.m.11 views

CVE-2020-5367

Dell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an improper certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this...

8.1CVSS7.3AI score0.00594EPSS
SaveExploits0References1
Prion
Prion
added 2020/06/23 8:15 p.m.24 views

Input validation

Dell EMC Unisphere for PowerMax versions prior to 9.1.0.17, Dell EMC Unisphere for PowerMax Virtual Appliance versions prior to 9.1.0.17, and PowerMax OS Release 5978 contain an improper certificate validation vulnerability. An unauthenticated remote attacker may potentially exploit this...

6.8CVSS7.8AI score0.00594EPSS
SaveExploits0References1Affected Software3
CNVD
CNVD
added 2020/06/19 12:00 a.m.16 views

BIOTRONIK CardioMessenger II-S Authorization Issue Vulnerability (CNVD-2020-52054)

The Biotronik CardioMessenger II-S is a portable medical monitoring device from Biotronik Germany. A security vulnerability exists in the Biotronik CardioMessenger II-S T-Line T4APP version 2.20 and II-S GSM T4APP version 2.20, which originates from a program that can recover format-stored...

4.6CVSS6.8AI score0.00359EPSS
SaveExploits0References1
Exploit DB
Exploit DB
added 2020/06/12 12:00 a.m.610 views

Avaya IP Office 11 - Password Disclosure

Exploit Title: Avaya IP Office 11 - Password Disclosure Exploit Author: hyp3rlinx Date: 2020-06-09 Vender Homepage: https://downloads.avaya.com Product Link: https://downloads.avaya.com/css/P8/documents/101067493 CVE: CVE-2020-7030 + Credits: John Page aka hyp3rlinx + Website:...

5.5CVSS5.6AI score0.01044EPSS
SaveExploits3
zdt
zdt
added 2020/06/08 12:00 a.m.370 views

Avaya IP Office 11 Insecure Transit / Password Disclosure Vulnerability

Avaya IP Office versions 9.1.8.0 through 11 suffer from an insecure transit vulnerability that allows for password disclosure. + Credits: John Page aka hyp3rlinx + Website: hyp3rlinx.altervista.org + Source:...

5.5CVSS5.6AI score0.01044EPSS
SaveExploits3
Packet Storm
Packet Storm
added 2020/06/05 12:00 a.m.432 views

Avaya IP Office 11 Insecure Transit / Password Disclosure

Credits: John Page aka hyp3rlinx + Website: hyp3rlinx.altervista.org + Source: http://hyp3rlinx.altervista.org/advisories/AVAYA-IP-OFFICE-INSECURE-TRANSIT-PASSWORD-DISCLOSURE.txt + twitter.com/hyp3rlinx + ISR: ApparitionSec Vendor www.avaya.com Product Avaya IP Office v9.1.8.0 - 11 IP Office...

2.1CVSS0.01044EPSS
SaveExploits3
OSV
OSV
added 2020/04/24 2:15 p.m.13 views

CVE-2020-5869

In BIG-IQ 5.2.0-7.0.0, high availability HA synchronization is not secure by TLS and may allow on-path attackers to read / modify confidential data in transit...

9.1CVSS7.3AI score0.00485EPSS