25 matches found
CVE-2017-9853
An issue was discovered in SMA Solar Technology products. All inverters have a very weak password policy for the user and installer password. No complexity requirements or length requirements are set. Also, strong passwords are impossible due to a maximum of 12 characters and a limited set of...
CVE-2017-9851
An issue was discovered in SMA Solar Technology products. By sending nonsense data or setting up a TELNET session to the database port of Sunny Explorer, the application can be crashed. NOTE: the vendor reports that the maximum possible damage is a communication failure. Also, only Sunny Boy...
CVE-2017-9859
An issue was discovered in SMA Solar Technology products. The inverters make use of a weak hashing algorithm to encrypt the password for REGISTER requests. This hashing algorithm can be cracked relatively easily. An attacker will likely be able to crack the password using offline crackers. This...
CVE-2017-9855
An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the installer...
CVE-2017-9851
An issue was discovered in SMA Solar Technology products. By sending nonsense data or setting up a TELNET session to the database port of Sunny Explorer, the application can be crashed. NOTE: the vendor reports that the maximum possible damage is a communication failure. Also, only Sunny Boy...
CVE-2017-9858
CVE-2017-9858 affects SMA Solar Technology inverters (Sunny Boy TLST-21, TL-21; Sunny Tripower TL-10, TL-30). By sending crafted packets to the inverter and observing responses, an attacker can determine which user accounts are active or inactive, enabling brute-force planning. The vendor notes t...
CVE-2017-9864
Summary of CVE-2017-9864 (SMA Solar Technology inverter/time setting issue) : An attacker can change the plant time on SMA Solar Technology inverters (notably Sunny Boy TLST-21/TL-21 and Sunny Tripower TL-10/TL-30) without authentication, causing the system time to shift. This can affect timestam...
CVE-2017-9856
The connected PT-2017-19222 entry confirms concrete technical details: SMA Solar Technology inverters (Sunny Boy TLST-21/TL-21 and Sunny Tripower TL-10/TL-30) use a simple encryption algorithm for SMAdata2+ passwords, allowing an attacker to decrypt passwords to plaintext and authenticate to the ...
CVE-2017-9851
An issue was discovered in SMA Solar Technology products. By sending nonsense data or setting up a TELNET session to the database port of Sunny Explorer, the application can be crashed. NOTE: the vendor reports that the maximum possible damage is a communication failure. Also, only Sunny Boy...
CVE-2017-9859: Use of a Broken or Risky Cryptographic Algorithm
An issue was discovered in SMA Solar Technology products. The inverters make use of a weak hashing algorithm to encrypt the password for REGISTER requests. This hashing algorithm can be cracked relatively easily. An attacker will likely be able to crack the password using offline crackers. This...
PT-2017-19225 · Sma Solar Technology · Tl-30 +3
Name of the Vulnerable Software and Affected Versions: SMA Solar Technology products, specifically Sunny Boy TLST-21, TL-21, Sunny Tripower TL-10, and TL-30 affected versions not specified Description: An issue was discovered in SMA Solar Technology products where the inverters use a weak hashing...
CVE-2017-9864: Undefined Security Weakness
An issue was discovered in SMA Solar Technology products. An attacker can change the plant time even when not authenticated in any way. This changes the system time, possibly affecting lockout policies and random-number generators based on timestamps, and makes timestamps for data analysis...
CVE-2017-9858: Exposure of Sensitive Information to an Unauthorized Actor
An issue was discovered in SMA Solar Technology products. By sending crafted packets to an inverter and observing the response, active and inactive user accounts can be determined. This aids in further attacks such as a brute force attack as one now knows exactly which users exist and which do no...
CVE-2017-9860: Improper Authentication
An issue was discovered in SMA Solar Technology products. An attacker can use Sunny Explorer or the SMAdata2+ network protocol to update the device firmware without ever having to authenticate. If an attacker is able to create a custom firmware version that is accepted by the inverter, the invert...
CVE-2017-9852: Use of Hard-coded Credentials
An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company but a...
CVE-2017-9855: Incorrect Authorization
An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the installer...
CVE-2017-9863: Cross-Site Request Forgery (CSRF)
An issue was discovered in SMA Solar Technology products. If a user simultaneously has Sunny Explorer running and visits a malicious host, cross-site request forgery can be used to change settings in the inverters for example, issuing a POST request to change the user password. All Sunny Explorer...
CVE-2017-9851: Undefined Security Weakness
An issue was discovered in SMA Solar Technology products. By sending nonsense data or setting up a TELNET session to the database port of Sunny Explorer, the application can be crashed. NOTE: the vendor reports that the maximum possible damage is a communication failure. Also, only Sunny Boy...
PT-2017-19220 · Sma Solar Technology · Sunny Tripower +3
Name of the Vulnerable Software and Affected Versions: SMA Solar Technology products affected versions not specified Sunny Boy versions TLST-21 and TL-21 Sunny Tripower versions TL-10 and TL-30 Description: An issue was discovered in SMA Solar Technology products where plaintext passwords can be...
PT-2017-19230 · Sma Solar Technology · Sunny Boy Tlst-21 +2
Name of the Vulnerable Software and Affected Versions: SMA Solar Technology products, specifically Sunny Boy TLST-21, TL-21, and Sunny Tripower TL-10, TL-30 Description: An issue allows an attacker to change the plant time without authentication, potentially affecting system time and making...