Lucene search
+L

25 matches found

NVD
NVD
•added 2017/08/05 5:29 p.m.•29 views

CVE-2017-9853

An issue was discovered in SMA Solar Technology products. All inverters have a very weak password policy for the user and installer password. No complexity requirements or length requirements are set. Also, strong passwords are impossible due to a maximum of 12 characters and a limited set of...

9.8CVSS9.5AI score0.01716EPSS
SaveExploits0References3
NVD
NVD
•added 2017/08/05 5:29 p.m.•38 views

CVE-2017-9851

An issue was discovered in SMA Solar Technology products. By sending nonsense data or setting up a TELNET session to the database port of Sunny Explorer, the application can be crashed. NOTE: the vendor reports that the maximum possible damage is a communication failure. Also, only Sunny Boy...

7.5CVSS7.6AI score0.01865EPSS
SaveExploits0References3
Cvelist
Cvelist
•added 2017/08/05 5:00 p.m.•45 views

CVE-2017-9859

An issue was discovered in SMA Solar Technology products. The inverters make use of a weak hashing algorithm to encrypt the password for REGISTER requests. This hashing algorithm can be cracked relatively easily. An attacker will likely be able to crack the password using offline crackers. This...

9.4AI score0.01127EPSS
SaveExploits0References3
CVE
CVE
•added 2017/08/05 5:00 p.m.•130 views

CVE-2017-9856

The connected PT-2017-19222 entry confirms concrete technical details: SMA Solar Technology inverters (Sunny Boy TLST-21/TL-21 and Sunny Tripower TL-10/TL-30) use a simple encryption algorithm for SMAdata2+ passwords, allowing an attacker to decrypt passwords to plaintext and authenticate to the ...

9.8CVSS9.2AI score0.00664EPSS
SaveExploits0References3Affected Software1
Vulnrichment
Vulnrichment
•added 2017/08/05 5:00 p.m.•47 views

CVE-2017-9851

An issue was discovered in SMA Solar Technology products. By sending nonsense data or setting up a TELNET session to the database port of Sunny Explorer, the application can be crashed. NOTE: the vendor reports that the maximum possible damage is a communication failure. Also, only Sunny Boy...

7.1AI score0.01865EPSS
SaveExploits0References3
CVE
CVE
•added 2017/08/05 5:00 p.m.•67 views

CVE-2017-9864

Summary of CVE-2017-9864 (SMA Solar Technology inverter/time setting issue) : An attacker can change the plant time on SMA Solar Technology inverters (notably Sunny Boy TLST-21/TL-21 and Sunny Tripower TL-10/TL-30) without authentication, causing the system time to shift. This can affect timestam...

7.5CVSS7.5AI score0.01512EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
•added 2017/08/05 5:00 p.m.•46 views

CVE-2017-9851

An issue was discovered in SMA Solar Technology products. By sending nonsense data or setting up a TELNET session to the database port of Sunny Explorer, the application can be crashed. NOTE: the vendor reports that the maximum possible damage is a communication failure. Also, only Sunny Boy...

7.6AI score0.01865EPSS
SaveExploits0References3
Cvelist
Cvelist
•added 2017/08/05 5:00 p.m.•51 views

CVE-2017-9855

An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the installer...

9.6AI score0.01583EPSS
SaveExploits0References3
CVE
CVE
•added 2017/08/05 5:00 p.m.•70 views

CVE-2017-9858

CVE-2017-9858 affects SMA Solar Technology inverters (Sunny Boy TLST-21, TL-21; Sunny Tripower TL-10, TL-30). By sending crafted packets to the inverter and observing responses, an attacker can determine which user accounts are active or inactive, enabling brute-force planning. The vendor notes t...

7.5CVSS7.4AI score0.02058EPSS
SaveExploits0References3Affected Software1
Positive Technologies
Positive Technologies
•added 2017/08/05 12:00 a.m.•20 views

PT-2017-19225 · Sma Solar Technology · Tl-30 +3

Name of the Vulnerable Software and Affected Versions: SMA Solar Technology products, specifically Sunny Boy TLST-21, TL-21, Sunny Tripower TL-10, and TL-30 affected versions not specified Description: An issue was discovered in SMA Solar Technology products where the inverters use a weak hashing...

9.8CVSS6.9AI score0.01127EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/08/05 12:00 a.m.•13 views

CVE-2017-9859: Use of a Broken or Risky Cryptographic Algorithm

An issue was discovered in SMA Solar Technology products. The inverters make use of a weak hashing algorithm to encrypt the password for REGISTER requests. This hashing algorithm can be cracked relatively easily. An attacker will likely be able to crack the password using offline crackers. This...

9.8CVSS5.7AI score0.01127EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/08/05 12:00 a.m.•8 views

CVE-2017-9856: Plaintext Storage of a Password

An issue was discovered in SMA Solar Technology products. Sniffed passwords from SMAdata2+ communication can be decrypted very easily. The passwords are "encrypted" using a very simple encryption algorithm. This enables an attacker to find the plaintext passwords and authenticate to the device...

9.8CVSS5.8AI score0.00664EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/08/05 12:00 a.m.•9 views

CVE-2017-9853: Weak Password Requirements

An issue was discovered in SMA Solar Technology products. All inverters have a very weak password policy for the user and installer password. No complexity requirements or length requirements are set. Also, strong passwords are impossible due to a maximum of 12 characters and a limited set of...

9.8CVSS5.7AI score0.01716EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/08/05 12:00 a.m.•10 views

CVE-2017-9851: Undefined Security Weakness

An issue was discovered in SMA Solar Technology products. By sending nonsense data or setting up a TELNET session to the database port of Sunny Explorer, the application can be crashed. NOTE: the vendor reports that the maximum possible damage is a communication failure. Also, only Sunny Boy...

7.5CVSS5.7AI score0.01865EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/08/05 12:00 a.m.•9 views

CVE-2017-9860: Improper Authentication

An issue was discovered in SMA Solar Technology products. An attacker can use Sunny Explorer or the SMAdata2+ network protocol to update the device firmware without ever having to authenticate. If an attacker is able to create a custom firmware version that is accepted by the inverter, the invert...

10CVSS5.7AI score0.02244EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2017/08/05 12:00 a.m.•18 views

PT-2017-19229 · Sma Solar Technology · Sunny Boy Tlst-21 +3

Name of the Vulnerable Software and Affected Versions: SMA Solar Technology products, specifically Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 Description: An issue in SMA Solar Technology products allows for cross-site request forgery, enabling an attacker to change settings i...

8.8CVSS6.8AI score0.00696EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2017/08/05 12:00 a.m.•16 views

PT-2017-19230 · Sma Solar Technology · Sunny Boy Tlst-21 +2

Name of the Vulnerable Software and Affected Versions: SMA Solar Technology products, specifically Sunny Boy TLST-21, TL-21, and Sunny Tripower TL-10, TL-30 Description: An issue allows an attacker to change the plant time without authentication, potentially affecting system time and making...

7.5CVSS7.2AI score0.01512EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
•added 2017/08/05 12:00 a.m.•24 views

PT-2017-19221 · Sma Solar Technology · Sunny Tripower +2

Name of the Vulnerable Software and Affected Versions: SMA Solar Technology products affected versions not specified Sunny Boy versions TLST-21 and TL-21 Sunny Tripower versions TL-10 and TL-30 Description: An issue was discovered in SMA Solar Technology products, related to the Grid Guard system...

9.8CVSS7.2AI score0.01583EPSS
SaveExploits0References6
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/08/05 12:00 a.m.•12 views

CVE-2017-9855: Incorrect Authorization

An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the installer...

9.8CVSS5.7AI score0.01583EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/08/05 12:00 a.m.•11 views

CVE-2017-9863: Cross-Site Request Forgery (CSRF)

An issue was discovered in SMA Solar Technology products. If a user simultaneously has Sunny Explorer running and visits a malicious host, cross-site request forgery can be used to change settings in the inverters for example, issuing a POST request to change the user password. All Sunny Explorer...

8.8CVSS5.7AI score0.00696EPSS
SaveExploits0References2
Rows per page
Query Builder