43 matches found
EUVD-2018-16627
Malware in sbrugna...
EUVD-2018-5752
Malware in sbrugna...
EUVD-2022-43523
Malicious code in bioql PyPI...
CVE-2023-28827: NULL Pointer Dereference
A vulnerability has been identified in SIMATIC CP 1242-7 V2 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 DNP3 incl. SIPLUS variants All versions V3.5.20, SIMATIC CP 1243-1 IEC incl. SIPLUS variants All versions V3.5.20...
Siemens TIM 1531 IRC Digit Type Error Conversion Vulnerability
The TIM 1531 IRC is a communication module for SIMATIC S7-1500, S7-400, S7-300. The Siemens TIM 1531 IRC suffers from a number type miscommunication vulnerability that can be exploited by an attacker to cause a denial of service condition on an affected device...
CVE-2022-40225
A vulnerability has been identified in SIPLUS TIM 1531 IRC 6AG1543-1MX00-7XE0 All versions V2.4.8, TIM 1531 IRC 6GK7543-1MX00-0XE0 All versions V2.4.8. Casting an internal value could lead to floating point exception under certain circumstances. This could allow an attacker to cause a denial of...
CVE-2022-40225
A vulnerability has been identified in SIPLUS TIM 1531 IRC 6AG1543-1MX00-7XE0 All versions V2.4.8, TIM 1531 IRC 6GK7543-1MX00-0XE0 All versions V2.4.8. Casting an internal value could lead to floating point exception under certain circumstances. This could allow an attacker to cause a denial of...
CVE-2023-50763
Siemens CVE-2023-50763 affects multiple Siemens/SIPLUS products (e.g., SIMATIC CP 1542SP-1 IRC/CP 1543SP-1, SIPLUS ET 200SP variants, TIM 1531 IRC) where the web server may loop infinitely when processing incomplete PKCS12 certificate chains. This authenticated remote vulnerability could allow a ...
多款Siemens产品 安全漏洞
The TIM 1531 IRC is a communication module for SIMATIC S7-1500, S7-400, S7-300. An infinite loop vulnerability exists in the Siemens TIM 1531 IRC, which can be exploited by an authenticated, remote attacker to create a denial of service condition by importing a specially crafted PKCS12 container...
CVE-2022-40225: Incorrect Conversion between Numeric Types
A vulnerability has been identified in SIPLUS TIM 1531 IRC 6AG1543-1MX00-7XE0 All versions V2.4.8, TIM 1531 IRC 6GK7543-1MX00-0XE0 All versions V2.4.8. Casting an internal value could lead to floating point exception under certain circumstances. This could allow an attacker to cause a denial of...
Siemens TIM 1531 IRC
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
PT-2023-9402 · Siemens · Siplus S7-1200 Cp 1243-1 +20
Name of the Vulnerable Software and Affected Versions: SIMATIC CP 1242-7 V2 versions prior to V3.4.29 SIMATIC CP 1243-1 versions prior to V3.4.29 SIMATIC CP 1243-1 DNP3 versions prior to V3.4.29 SIMATIC CP 1243-1 IEC versions prior to V3.4.29 SIMATIC CP 1243-7 LTE EU versions prior to V3.4.29...
Siemens Industrial Product Denial of Service Vulnerability (CNVD-2022-87982)
SIMATIC Drive Controllers for the automation of production machines combine the functionality of SIMATIC S7-1500 CPUs with that of SINAMICS S120 drive controls.SIMATIC ET 200SP Open Controller is the PC-based version of the SIMATIC S7-1500 controller. Includes optional visualization features and...
Siemens Industrial Product Denial of Service Vulnerability
SIMATIC Drive Controllers for the automation of production machines combine the functionality of SIMATIC S7-1500 CPUs with that of SINAMICS S120 drive controls.SIMATIC ET 200SP Open Controller is the PC-based version of the SIMATIC S7-1500 controller. Includes optional visualization features and...
CVE-2022-40225
A vulnerability has been identified in SIPLUS TIM 1531 IRC 6AG1543-1MX00-7XE0 All versions V2.4.8, TIM 1531 IRC 6GK7543-1MX00-0XE0 All versions V2.4.8. Casting an internal value could lead to floating point exception under certain circumstances. This could allow an attacker to cause a denial of...
Siemens SIPLUS TIM 1531 IRC 安全漏洞
The TIM 1531 IRC is a communication module for SIMATIC S7-1500, S7-400, S7-300. The Siemens TIM 1531 IRC suffers from a number type miscommunication vulnerability that can be exploited by an attacker to cause a denial of service condition on an affected device...
PT-2022-25293
Name of the Vulnerable Software and Affected Versions SIPLUS TIM 1531 IRC 6AG1543-1MX00-7XE0 versions prior to V2.4.8 TIM 1531 IRC 6GK7543-1MX00-0XE0 versions prior to V2.4.8 Description A vulnerability has been identified that could lead to a floating point exception under certain circumstances...
Siemens SIMATIC Industrial Products Operation On a Resource After Expiration or Release (CVE-2021-37185)
A vulnerability has been identified in SIMATIC Drive Controller family All versions = V2.9.2 = V21.9 = V4.5.0 = V2.9.2 = V21.9 = V4.0 V4.0 SP1, SIPLUS TIM 1531 IRC All versions V2.3.6, TIM 1531 IRC All versions V2.3.6. An unauthenticated attacker could cause a denial- of-service condition in a PL...
CVE-2021-37204
A vulnerability has been identified in SIMATIC Drive Controller family All versions = V2.9.2 = V21.9 = V4.5.0 = V2.9.2 = V21.9 = V4.0 V4.0 SP1, SIPLUS TIM 1531 IRC All versions V2.3.6, TIM 1531 IRC All versions V2.3.6. An unauthenticated attacker could cause a denial-of-service condition in a PLC...
CVE-2021-37185: Operation on a Resource after Expiration or Release
A vulnerability has been identified in SIMATIC Drive Controller family All versions = V2.9.2 = V21.9 = V4.5.0 = V2.9.2 = V21.9 = V4.0 V4.0 SP1, SIPLUS TIM 1531 IRC All versions V2.3.6, TIM 1531 IRC All versions V2.3.6. An unauthenticated attacker could cause a denial-of-service condition in a PLC...