Lucene search
+L

10 matches found

EUVD
EUVD
•added 2025/10/07 12:30 a.m.•17 views

EUVD-2020-4286

Malware in sbrugna...

6.5CVSS6.7AI score0.01194EPSS
SaveExploits0References2
OSV
OSV
•added 2020/05/28 1:15 p.m.•12 views

CVE-2020-11949

testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x and before XXXXX-VVTK-0XXXXBeta2 allows an authenticated user to obtain arbitrary files from a camera's local filesystem. For example, this affects IT9388-HT devices...

6.5CVSS6.7AI score0.01194EPSS
SaveExploits0References1
NVD
NVD
•added 2020/05/28 1:15 p.m.•22 views

CVE-2020-11949

testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x and before XXXXX-VVTK-0XXXXBeta2 allows an authenticated user to obtain arbitrary files from a camera's local filesystem. For example, this affects IT9388-HT devices...

6.5CVSS6.3AI score0.01194EPSS
SaveExploits0References1
CVE
CVE
•added 2020/05/28 12:43 p.m.•172 views

CVE-2020-11949

CVE-2020-11949 affects VIVOTEK Network Cameras and their web service (testserver.cgi) before XXXXX-VVTK-2.2002.xx.01x and before XXXXX-VVTK-0XXXX_Beta2. An authenticated user can obtain arbitrary files from a camera’s local filesystem (affecting devices such as IT9388-HT). The underlying cause is...

6.5CVSS6.3AI score0.01194EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2020/05/28 12:43 p.m.•36 views

CVE-2020-11949

testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x and before XXXXX-VVTK-0XXXXBeta2 allows an authenticated user to obtain arbitrary files from a camera's local filesystem. For example, this affects IT9388-HT devices...

6.3AI score0.01194EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2020/05/28 12:00 a.m.•2 views

PT-2020-12942

Name of the Vulnerable Software and Affected Versions VIVOTEK Network Cameras versions before XXXXX-VVTK-2.2002.xx.01x VIVOTEK Network Cameras versions before XXXXX-VVTK-0XXXX Beta2 Description The issue allows an authenticated user to obtain arbitrary files from a camera's local filesystem. This...

6.5CVSS0.01194EPSS
SaveExploits0References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/05/28 12:00 a.m.•7 views

CVE-2020-11949: Undefined Security Weakness

testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x and before XXXXX-VVTK-0XXXXBeta2 allows an authenticated user to obtain arbitrary files from a camera's local filesystem. For example, this affects IT9388-HT devices...

6.5CVSS6.7AI score0.01194EPSS
SaveExploits0References1
BDU FSTEC
BDU FSTEC
•added 2017/08/25 12:00 a.m.•19 views

A vulnerability exists in the /cgi-bin/admin/testserver.cgi web service of the microprogramming software for network cameras, namely the Network Camera IB8369, FD8164, and FD816BA. This vulnerability allows a hacker to execute any shell command with superuser privileges.

The vulnerability in the /cgi-bin/admin/testserver.cgi web service of the microprogramming-based network camera software models IB8369, FD8164, and FD816BA is related to insufficient processing of input data. Exploiting this vulnerability allows a malicious actor to execute any shell command with...

10CVSS7.9AI score0.82455EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2017/06/23 12:00 a.m.•5 views

CVE-2017-9828: Improper Neutralization of Special Elements used in an OS Command

'/cgi-bin/admin/testserver.cgi' of the web service in most of the VIVOTEK Network Cameras is vulnerable to shell command injection, which allows remote attackers to execute any shell command as root via a crafted HTTP request. This vulnerability is already verified on VIVOTEK Network Camera...

10CVSS8.3AI score0.82455EPSS
SaveExploits1References2
Positive Technologies
Positive Technologies
•added 2017/06/23 12:00 a.m.•3 views

PT-2017-2639

Name of the Vulnerable Software and Affected Versions VIVOTEK Network Camera IB8369, FD8164, and FD816BA affected versions not specified Description The issue is related to insufficient input processing in the /cgi-bin/admin/testserver.cgi web service of the network camera's firmware. This allows...

10CVSS0.82455EPSS
SaveExploits1References4
Rows per page
Query Builder