10 matches found
EUVD-2020-4286
Malware in sbrugna...
CVE-2020-11949
testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x and before XXXXX-VVTK-0XXXXBeta2 allows an authenticated user to obtain arbitrary files from a camera's local filesystem. For example, this affects IT9388-HT devices...
CVE-2020-11949
testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x and before XXXXX-VVTK-0XXXXBeta2 allows an authenticated user to obtain arbitrary files from a camera's local filesystem. For example, this affects IT9388-HT devices...
CVE-2020-11949
CVE-2020-11949 affects VIVOTEK Network Cameras and their web service (testserver.cgi) before XXXXX-VVTK-2.2002.xx.01x and before XXXXX-VVTK-0XXXX_Beta2. An authenticated user can obtain arbitrary files from a camera’s local filesystem (affecting devices such as IT9388-HT). The underlying cause is...
CVE-2020-11949
testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x and before XXXXX-VVTK-0XXXXBeta2 allows an authenticated user to obtain arbitrary files from a camera's local filesystem. For example, this affects IT9388-HT devices...
PT-2020-12942
Name of the Vulnerable Software and Affected Versions VIVOTEK Network Cameras versions before XXXXX-VVTK-2.2002.xx.01x VIVOTEK Network Cameras versions before XXXXX-VVTK-0XXXX Beta2 Description The issue allows an authenticated user to obtain arbitrary files from a camera's local filesystem. This...
CVE-2020-11949: Undefined Security Weakness
testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x and before XXXXX-VVTK-0XXXXBeta2 allows an authenticated user to obtain arbitrary files from a camera's local filesystem. For example, this affects IT9388-HT devices...
A vulnerability exists in the /cgi-bin/admin/testserver.cgi web service of the microprogramming software for network cameras, namely the Network Camera IB8369, FD8164, and FD816BA. This vulnerability allows a hacker to execute any shell command with superuser privileges.
The vulnerability in the /cgi-bin/admin/testserver.cgi web service of the microprogramming-based network camera software models IB8369, FD8164, and FD816BA is related to insufficient processing of input data. Exploiting this vulnerability allows a malicious actor to execute any shell command with...
CVE-2017-9828: Improper Neutralization of Special Elements used in an OS Command
'/cgi-bin/admin/testserver.cgi' of the web service in most of the VIVOTEK Network Cameras is vulnerable to shell command injection, which allows remote attackers to execute any shell command as root via a crafted HTTP request. This vulnerability is already verified on VIVOTEK Network Camera...
PT-2017-2639
Name of the Vulnerable Software and Affected Versions VIVOTEK Network Camera IB8369, FD8164, and FD816BA affected versions not specified Description The issue is related to insufficient input processing in the /cgi-bin/admin/testserver.cgi web service of the network camera's firmware. This allows...