Lucene search
+L

6362 matches found

Positive Technologies
Positive Technologies
added 2025/01/17 12:0 a.m.4 views

PT-2025-5299 · Apple · Ipados +6

Name of the Vulnerable Software and Affected Versions: visionOS versions prior to 2.3 iOS versions prior to 18.3 iPadOS versions prior to 18.3 macOS Sequoia versions prior to 15.3 watchOS versions prior to 11.3 tvOS versions prior to 18.3 Description: An input validation issue was addressed, whic...

10CVSS9AI score0.01342EPSS
SaveExploits0References22
Positive Technologies
Positive Technologies
added 2025/01/17 12:0 a.m.8 views

PT-2025-5302 · Apple · Ipados +5

Name of the Vulnerable Software and Affected Versions: visionOS versions prior to 2.3 iOS versions prior to 18.3 iPadOS versions prior to 18.3 macOS Sequoia versions prior to 15.3 watchOS versions prior to 11.3 tvOS versions prior to 18.3 Description: A type confusion issue was addressed with...

7.8CVSS8.2AI score0.01305EPSS
SaveExploits0References23
OSV
OSV
added 2025/01/15 8:15 p.m.11 views

CVE-2024-27856

The issue was addressed with improved checks. This issue is fixed in macOS Sonoma 14.5, iOS 16.7.8 and iPadOS 16.7.8, Safari 17.5, iOS 17.5 and iPadOS 17.5, watchOS 10.5, tvOS 17.5, visionOS 1.2. Processing a file may lead to unexpected app termination or arbitrary code execution...

7.8CVSS7.2AI score
SaveExploits0References7
NVD
NVD
added 2025/01/15 8:15 p.m.12 views

CVE-2024-27856

The issue was addressed with improved checks. This issue is fixed in Safari 17.5, iOS 16.7.8 and iPadOS 16.7.8, iOS 17.5 and iPadOS 17.5, macOS Sonoma 14.5, tvOS 17.5, visionOS 1.2, watchOS 10.5. Processing a file may lead to unexpected app termination or arbitrary code execution...

7.8CVSS0.00626EPSS
SaveExploits0References7
NVD
NVD
added 2025/01/15 8:15 p.m.14 views

CVE-2024-40854

A memory initialization issue was addressed with improved memory handling. This issue is fixed in iOS 17.7.1 and iPadOS 17.7.1, iOS 18.1 and iPadOS 18.1, macOS Sequoia 15.1, macOS Sonoma 14.7.1, macOS Ventura 13.7.1. An app may be able to cause unexpected system termination...

6.5CVSS0.00398EPSS
SaveExploits0References5
OSV
OSV
added 2025/01/15 8:15 p.m.6 views

CVE-2024-40854

A memory initialization issue was addressed with improved memory handling. This issue is fixed in iOS 18.1 and iPadOS 18.1, iOS 17.7.1 and iPadOS 17.7.1, macOS Sonoma 14.7.1, macOS Ventura 13.7.1. An app may be able to cause unexpected system termination...

5.5CVSS5.7AI score0.00398EPSS
SaveExploits0References4
CVE
CVE
added 2025/01/15 7:35 p.m.79 views

CVE-2024-40854

CVE-2024-40854 describes a memory initialization issue addressed by Apple in macOS/OS updates. Affected components are iOS 18.1 and iPadOS 18.1, iOS 17.7.1 and iPadOS 17.7.1, macOS Sonoma 14.7.1, and macOS Ventura 13.7.1. The vulnerability may allow an app to cause an unexpected system terminatio...

6.5CVSS5.8AI score0.00398EPSS
SaveExploits0References5Affected Software3
Cvelist
Cvelist
added 2025/01/15 7:35 p.m.27 views

CVE-2024-40854

A memory initialization issue was addressed with improved memory handling. This issue is fixed in iOS 17.7.1 and iPadOS 17.7.1, iOS 18.1 and iPadOS 18.1, macOS Sequoia 15.1, macOS Sonoma 14.7.1, macOS Ventura 13.7.1. An app may be able to cause unexpected system termination...

0.00398EPSS
SaveExploits0References5
Vulnrichment
Vulnrichment
added 2025/01/15 7:35 p.m.10 views

CVE-2024-40854

A memory initialization issue was addressed with improved memory handling. This issue is fixed in iOS 18.1 and iPadOS 18.1, iOS 17.7.1 and iPadOS 17.7.1, macOS Sonoma 14.7.1, macOS Ventura 13.7.1. An app may be able to cause unexpected system termination...

5.9AI score0.00398EPSS
SaveExploits0References4
Vulnrichment
Vulnrichment
added 2025/01/15 7:35 p.m.8 views

CVE-2024-27856

The issue was addressed with improved checks. This issue is fixed in Safari 17.5, iOS 16.7.8 and iPadOS 16.7.8, iOS 17.5 and iPadOS 17.5, macOS Sonoma 14.5, tvOS 17.5, visionOS 1.2, watchOS 10.5. Processing a file may lead to unexpected app termination or arbitrary code execution...

7.3AI score0.00626EPSS
SaveExploits0References7
CVE
CVE
added 2025/01/15 7:35 p.m.184 views

CVE-2024-27856

CVE-2024-27856 affects the WebKitGTK/ WebKit component used by Apple platforms in the provided set (macOS, iOS, iPadOS, watchOS, tvOS, visionOS). The description across connected advisories states the issue can cause an unexpected app termination or arbitrary code execution when processing a file...

7.8CVSS7.3AI score0.00626EPSS
SaveExploits0References7Affected Software7
Debian CVE
Debian CVE
added 2025/01/15 7:35 p.m.5 views

CVE-2024-27856

The issue was addressed with improved checks. This issue is fixed in Safari 17.5, iOS 16.7.8 and iPadOS 16.7.8, iOS 17.5 and iPadOS 17.5, macOS Sonoma 14.5, tvOS 17.5, visionOS 1.2, watchOS 10.5. Processing a file may lead to unexpected app termination or arbitrary code execution...

7.8CVSS8.2AI score0.00626EPSS
SaveExploits0
CNNVD
CNNVD
added 2025/01/15 12:0 a.m.3 views

Apple iOS和Apple iPadOS 安全漏洞

Apple iOS and Apple iPadOS are products of Apple Inc. Apple iOS is an operating system developed for mobile devices, and Apple iPadOS is an operating system for iPad tablets. A security vulnerability exists in Apple iOS version 18.1 and Apple iPadOS version 18.1, which originates from an...

6.5CVSS6.2AI score0.00398EPSS
SaveExploits0References2
CNNVD
CNNVD
added 2025/01/14 12:0 a.m.10 views

TYPO3 安全漏洞

TYPO3 is a free and open source content management system framework CMS/CMF from the Swiss TYPO3 Association. A security vulnerability exists in TYPO3, which stems from the vulnerability of the back-end user interface deep linking functionality to a cross-site request forgery attack, which could...

5.4CVSS6.5AI score0.00244EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
added 2025/01/14 12:0 a.m.12 views

PT-2025-3145 · Typo3 · Typo3

Name of the Vulnerable Software and Affected Versions: TYPO3 versions prior to 11.5.42 ELTS TYPO3 versions prior to 12.4.25 LTS TYPO3 versions prior to 13.4.3 LTS Description: A vulnerability has been identified in the backend user interface functionality involving deep links, which is susceptibl...

4.3CVSS7AI score0.00244EPSS
SaveExploits0References12
OSV
OSV
added 2025/01/13 9:42 p.m.14 views

CVE-2024-51491 Process crash during CRL-based revocation check on OS using separate mount point for temp Directory in notation-go

notion-go is a collection of libraries for supporting sign and verify OCI artifacts. Based on Notary Project specifications. The issue was identified during Quarkslab's security audit on the Certificate Revocation List CRL based revocation check feature. After retrieving the CRL, notation-go...

3.3CVSS6.8AI score
SaveExploits0References5
Vulnrichment
Vulnrichment
added 2025/01/13 9:42 p.m.25 views

CVE-2024-51491 Process crash during CRL-based revocation check on OS using separate mount point for temp Directory in notation-go

notion-go is a collection of libraries for supporting sign and verify OCI artifacts. Based on Notary Project specifications. The issue was identified during Quarkslab's security audit on the Certificate Revocation List CRL based revocation check feature. After retrieving the CRL, notation-go...

3.3CVSS6.9AI score0.00195EPSS
SaveExploits1References3
NVD
NVD
added 2025/01/10 10:15 p.m.30 views

CVE-2025-23113

An issue was discovered in REDCap 14.9.6. It has an action=myprojects&logout=1 CSRF issue in the alert-title while performing an upload of a CSV file containing a list of alert configuration. An attacker can send the victim a CSV file containing an HTML injection payload in the alert-title. Once...

8.8CVSS0.00162EPSS
SaveExploits0References1
NVD
NVD
added 2025/01/10 9:15 p.m.12 views

CVE-2024-7095

On affected platforms running Arista EOS with SNMP configured, if “snmp-server transmit max-size” is configured, under some circumstances a specially crafted packet can cause the snmpd process to leak memory. This may result in the snmpd process being terminated causing SNMP requests to time out...

4.3CVSS0.00481EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2025/01/10 8:19 p.m.28 views

CVE-2024-7095 On affected platforms running Arista EOS with SNMP configured, if “snmp-server transmit max-size” is configured, under some circumstances a specially crafted packet can cause the snmpd process to leak memory. This may result in the snmpd process being term

On affected platforms running Arista EOS with SNMP configured, if “snmp-server transmit max-size” is configured, under some circumstances a specially crafted packet can cause the snmpd process to leak memory. This may result in the snmpd process being terminated causing SNMP requests to time out...

4.3CVSS0.00481EPSS
SaveExploits0References1
Rows per page
Query Builder