11754 matches found
Siemens SIMATIC S7-1500 Out-of-bounds Write (CVE-2021-20305)
A flaw was found in Nettle in versions before 3.7.2, where several Nettle signature verification functions GOST DSA, EDDSA & ECDSA result in the Elliptic Curve Cryptography point ECC multiply function being called with out-of-range scalers, possibly resulting in incorrect results. This flaw allow...
Siemens SIMATIC S7-1500 Improper Neutralization of Special Elements used in a Command (CVE-2015-20107)
In Python aka CPython up to 3.10.8, the mailcap module does not add escape characters into commands discovered in the system mailcap file. This may allow attackers to inject shell commands into applications that call mailcap.findmatch with untrusted input if they lack validation of user-provided...
Siemens SIMATIC S7-1500 Use After Free (CVE-2022-48560)
A use-after-free exists in Python through 3.9 via heappushpop in heapq. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid503972; scriptversion"1.3"...
Siemens SIMATIC S7-1500 Improper Restriction of Recursive Entity References in DTDs (CVE-2023-52426)
libexpat through 2.5.0 allows recursive XML Entity Expansion if XMLDTD is undefined at compile time. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description...
Siemens SIMATIC S7-1500 Uncontrolled Recursion (CVE-2021-3997)
A flaw was found in systemd. An uncontrolled recursion in systemd- tmpfiles may lead to a denial of service at boot time when too many nested directories are created in /tmp. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...
Siemens SIMATIC S7-1500 Improper Neutralization of Special Elements used in an OS Command (CVE-2020-15778)
scp in OpenSSH through 8.3p1 allows command injection in the scp.c toremote function, as demonstrated by backtick characters in the destination argument. NOTE: the vendor reportedly has stated that they intentionally omit validation of anomalous argument transfers because that could stand a great...
Siemens SIMATIC S7-1500 Improper Check for Dropped Privileges (CVE-2019-18276)
An issue was discovered in disableprivmode in shell.c in GNU Bash through 5.0 patch 11. By default, if Bash is run with its effective UID not equal to its real UID, it will drop privileges by setting its effective UID to its real UID. However, it does so incorrectly. On Linux and other systems th...
Siemens SIMATIC S7-1500 Integer Underflow (Wrap or Wraparound) (CVE-2020-36221)
An integer underflow was discovered in OpenLDAP before 2.4.57 leading to slapd crashes in the Certificate Exact Assertion processing, resulting in denial of service schemainit.c serialNumberAndIssuerCheck. This plugin only works with Tenable.ot. Please visit...
Siemens SIMATIC S7-1500 Missing Encryption of Sensitive Data (CVE-2019-19959)
ext/misc/zipfile.c in SQLite 3.30.1 mishandles certain uses of INSERT INTO in situations involving embedded '\0' characters in filenames, leading to a memory-management error that can be detected by for example valgrind. This plugin only works with Tenable.ot. Please visit...
Siemens SIMATIC S7-1500 Incorrect Calculation (CVE-2020-14422)
Lib/ipaddress.py in Python through 3.8.3 improperly computes hash values in the IPv4Interface and IPv6Interface classes, which might allow a remote attacker to cause a denial of service if an application is affected by the performance of a dictionary containing IPv4Interface or IPv6Interface...
Siemens SIMATIC S7-1500 Unchecked Return Value (CVE-2021-4189)
A flaw was found in Python, specifically in the FTP File Transfer Protocol client library in PASV passive mode. The issue is how the FTP client trusts the host from the PASV response by default. This flaw allows an attacker to set up a malicious FTP server that can trick FTP clients into connecti...
Siemens SIMATIC S7-1500 Out-of-bounds Write (CVE-2020-19190)
Buffer Overflow vulnerability in ncfindentry in tinfo/comphash.c:70 in ncurses 6.1 allows remote attackers to cause a denial of service via crafted command. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C...
Siemens SIMATIC S7-1500 Use After Free (CVE-2021-3516)
There's a flaw in libxml2's xmllint in versions before 2.9.11. An attacker who is able to submit a crafted file to be processed by xmllint could trigger a use-after-free. The greatest impact of this flaw is to confidentiality, integrity, and availability. This plugin only works with Tenable.ot...
Siemens SIMATIC S7-1500 Improper Handling of Exceptional Conditions (CVE-2019-20218)
selectExpander in select.c in SQLite 3.30.1 proceeds with WITH stack unwinding even after a parsing error. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description...
Siemens SIMATIC S7-1500 Improper Neutralization of CRLF Sequences (CVE-2019-9947)
An issue was discovered in urllib2 in Python 2.x through 2.7.16 and urllib in Python 3.x through 3.7.3. CRLF injection is possible if the attacker controls a url parameter, as demonstrated by the first argument to urllib.request.urlopen with \r\n specifically in the path component of a URL that...
Siemens SIMATIC S7-1500 Use After Free (CVE-2024-56601)
In the Linux kernel, the following vulnerability has been resolved: net: inet: do not leave a dangling sk pointer in inetcreate sockinitdata attaches the allocated sk object to the provided sock object. If inetcreate fails later, the sk object is freed, but the sock object retains the dangling...
Siemens SIMATIC S7-1500 Out-of-bounds Read (CVE-2024-56650)
In the Linux kernel, the following vulnerability has been resolved: netfilter: xtables: fix LED ID check in ledtgcheck Syzbot has reported the following BUG detected by KASAN This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...
Siemens SIMATIC S7-1500 Encoding Error (CVE-2019-10160)
A security regression of CVE-2019-9636 was discovered in python since commit d537ab0ff9767ef024f26246899728f0116b1ec3 affecting versions 2.7, 3.5, 3.6, 3.7 and from v3.8.0a4 through v3.8.0b1, which still allows an attacker to exploit CVE-2019-9636 by abusing the user and password parts of a URL...
Siemens SIMATIC S7-1500 Integer Overflow or Wraparound (CVE-2022-25314)
In Expat aka libexpat before 2.4.5, there is an integer overflow in copyString. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc. include'compat.inc'; if description scriptid504215;...
Siemens SIMATIC S7-1500 Improper Limitation of a Pathname to a Restricted Directory (CVE-2019-9948)
urllib in Python 2.x through 2.7.16 supports the localfile: scheme, which makes it easier for remote attackers to bypass protection mechanisms that blacklist file: URIs, as demonstrated by triggering a urllib.urlopen'localfile:///etc/passwd' call. This plugin only works with Tenable.ot. Please...