1740 matches found
Rockwell Automation Logix Controllers Insufficiently Protected Credentials (CVE-2021-22681)
Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730,...
Emerson DeltaV Improper Permissions, Privileges, and Access Controls (CVE-2012-1818)
An unspecified ActiveX control in Emerson DeltaV and DeltaV Workstations 9.3.1, 10.3.1, 11.3, and 11.3.1 and DeltaV ProEssentials Scientific Graph 5.0.0.6 allows remote attackers to overwrite arbitrary files via unknown vectors. This plugin only works with Tenable.ot. Please visit...
Siemens SIMATIC S7-1500 CPU Improper Input Validation (CVE-2018-16558)
A vulnerability has been identified in SIMATIC S7-1500 CPU All versions = V2.0 and V2.5, SIMATIC S7-1500 CPU All versions = V1.8.5. Specially crafted network packets sent to port 80/tcp or 443/tcp could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the device...
Johnson Controls Controller Asset Information
It is possible to obtain attributes of the remote Johnson Controls Controller device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. include'deprecatednasllevel.inc';...
Rockwell Automation Allen-Bradley PowerMonitor 1000 Improper Neutralization of Input During Web Page Generation (CVE-2018-19615)
Rockwell Automation Allen-Bradley PowerMonitor 1000 all versions. A remote attacker could inject arbitrary code into a targeted user's web browser to gain access to the affected device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more...
Schneider Electric Modicon Controllers Reliance On Untrusted Inputs in a Security Decision (CVE-2018-7850)
A CWE-807: Reliance on Untrusted Inputs in a Security Decision vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause invalid information displayed in Unity Pro software. This plugin only works with Tenable.ot. Please visit...
Siemens SIMATIC, SINUMERIK, and PROFINET IO Improper Input Validation (CVE-2018-4843)
A vulnerability has been identified in SIMATIC CP 343-1 incl. SIPLUS variants All versions, SIMATIC CP 343-1 Advanced incl. SIPLUS variants All versions, SIMATIC CP 443-1 All versions V3.3, SIMATIC CP 443-1 All versions V3.3, SIMATIC CP 443-1 Advanced All versions V3.3, SIMATIC ET 200pro IM154-8...
Beckhoff ADS protocol Authentication Bypass by Spoofing (CVE-2019-16871)
Beckhoff Embedded Windows PLCs through 3.1.4024.0, and Beckhoff Twincat on Windows Engineering stations, allow an attacker to achieve Remote Code Execution as SYSTEM via the Beckhoff ADS protocol. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for...
Schneider Electric Modicon Controllers and Software Authentication Bypass By Spoofing (CVE-2021-22779)
Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert all versions prior to V15.0 SP1, including all versions of Unity Pro, EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert all versions, including all versions of EcoStruxure Hybrid DCS, SCADAPack...
Siemens SIMATIC S7-1200 Improper Input Validation (CVE-2014-2258)
Siemens SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allow remote attackers to cause a denial of service defect-mode transition via crafted HTTPS packets, a different vulnerability than CVE-2014-2259. This plugin only works with Tenable.ot. Please visit...
Siemens KTK, SIDOOR, SIMATIC, and SINAMICS Uncontrolled Resource Consumption (CVE-2019-19300)
A vulnerability exists in affected products that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemen...
Schneider Electric Modicon Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2021-22789)
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability that could cause a Denial of Service on the Modicon PLC controller / simulator when updating the controller application with a specially crafted project file exists in Modicon M580 CPU part numbers BM...
Rockwell Automation Controller Asset Information
It is possible to obtain attributes of the remote Rockwell Controller device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. include'deprecatednasllevel.inc';...
Schneider Electric Modicon Injection (CVE-2020-7475)
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component 'Injection', reflective DLL, vulnerability exists in EcoStruxure Control Expert all versions prior to 14.1 Hot Fix, Unity Pro all versions, Modicon M340 all versions prior to V3.20, Modicon M580 all...
Dell OT Asset Information
It is possible to obtain attributes of the remote Dell OT device. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 70300 C Tenable Network Security, Inc. include'deprecatednasllevel.inc'; include"compat.inc"; if...
Schneider Electric Modicon Open Redirect (CVE-2018-7804)
A URL Redirection to Untrusted Site vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where a user clicking on a specially crafted link can be redirected to a URL of the attacker's choosing. This plugin only works with Tenable.ot. Please...
Mitsubishi Electric MELSEC iQ-R Resource Management Errors (CVE-2020-5658)
Resource Management Errors vulnerability in TCP/IP function included in the firmware of MELSEC iQ-R series RJ71EIP91 EtherNet/IP Network Interface Module First 2 digits of serial number are '02' or before, RJ71PN92 PROFINET IO Controller Module First 2 digits of serial number are '01' or before,...
Rockwell Automation MicroLogix 1400 Buffer Copy Without Checking Size of Input (CVE-2021-22659)
Rockwell Automation MicroLogix 1400 Version 21.6 and below may allow a remote unauthenticated attacker to send a specially crafted Modbus packet allowing the attacker to retrieve or modify random values in the register. If successfully exploited, this may lead to a buffer overflow resulting in a...
Schneider Electric Modicon Improper Check for Unusual or Exceptional Conditions (CVE-2020-7542)
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium see security notifications for affected versions, that could cause denial of service when a specially crafted Read Physical Memo...
Schneider Electric Modicon Controllers Uncaught Exception (CVE-2019-6809)
A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 firmware versions prior to V2.90, Modicon M340 firmware versions prior to V3.10, Modicon Premium all versions, Modicon Quantum all versions, which could cause a possible denial of service when reading invalid data from the...