1740 matches found
Siemens InsydeH2O Inclusion of Functionality from Untrusted Control Sphere (CVE-2021-33626)
A vulnerability exists in SMM System Management Mode branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointerQWORD values for CommBuffer. This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code executio...
Siemens InsydeH2O Out-of-bounds Write (CVE-2023-22613)
An issue was discovered in IhisiSmm in Insyde InsydeH2O with kernel 5.0 through 5.5. It is possible to write to an attacker-controlled address. An attacker could invoke an SMI handler with a malformed pointer in RCX that overlaps SMRAM, resulting in SMM memory corruption. Insyde BIOS is typically...
Siemens InsydeH2O Stack-Based Buffer Overflow (CVE-2021-42059)
An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.08.41, Kernel 5.1 before 05.16.41, Kernel 5.2 before 05.26.41, Kernel 5.3 before 05.35.41, and Kernel 5.4 before 05.42.20. A stack- based buffer overflow leads toarbitrary code execution in UEFI DisplayTypeDxe DXE driver. Insyde BIO...
Siemens InsydeH2O Out-of-bounds Write (CVE-2022-24030)
An issue was discovered in AhciBusDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM. Insyde BIOS is typically used in RUGGEDCO...
Siemens InsydeH2O Inclusion of Functionality from Untrusted Control Sphere (CVE-2021-41841)
An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere. Insyde BIOS...
Siemens InsydeH2O Out-of-bounds Write (CVE-2023-22615)
An issue was discovered in IhisiSmm in Insyde InsydeH2O with kernel 5.0 through 5.5. IHISI subfunction execution may corrupt SMRAM. An attacker can pass an address in the RCX save state register that overlaps SMRAM, thereby coercing an IHISI subfunction handler to overwrite private SMRAM. Insyde...
Siemens InsydeH2O Out-of-bounds Write (CVE-2022-24031)
An issue was discovered in NvmExpressDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM. Insyde BIOS is typically used in...
Siemens InsydeH2O Cleartext Storage of Sensitive Information (CVE-2023-31041)
An issue was discovered in SysPasswordDxe in Insyde InsydeH2O with kernel 5.0 through 5.5. System password information could optionally be stored in cleartext, which might lead to possible information disclosure. Insyde BIOS is typically used in RUGGEDCOM APE products and some SIMATIC devices...
Siemens InsydeH2O Improper Restriction of Operations within the Bounds of a Memory Buffer (CVE-2021-33625)
An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate function of the EFISMMCOMMUNICATIONPROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses. Insyde BIO...
Siemens InsydeH2O Classic Buffer Overflow (CVE-2022-24350)
An issue was discovered in IhisiSmm in Insyde InsydeH2O with kernel 5.0 through 5.5. IHISI function 0x17 verifies that the output buffer lies within the command buffer but does not verify that output data does not go beyond the end of the command buffer. In particular, the GetFlashTable function ...
Rockwell Automation Select Logix Communication Modules Stack-Based Buffer Overflow (CVE-2023-2262)
A buffer overflow vulnerability exists in the Rockwell Automation select 1756-EN communication devices. If exploited, a threat actor could potentially leverage this vulnerability to perform a remote code execution. To exploit this vulnerability, a threat actor would have to send a maliciously...
Siemens LOGO! CMR and SIMATIC RTU 3000 Incorrect Calculation of Buffer Size (CVE-2020-36475)
An issue was discovered in Mbed TLS before 2.25.0 and before 2.16.9 LTS and before 2.7.18 LTS. The calculations performed by mbedtlsmpiexpmod are not limited; thus, supplying overly large parameters could lead to denial of service when generating Diffie- Hellman key pairs. This plugin only works...
Siemens LOGO! 8 BM Improper Handling of Extra Values (CVE-2019-10920)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker wi...
Siemens LOGO! 8 BM Use of Hard-Coded Cryptographic Key (CVE-2020-25233)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. The firmware update of affected devices contains the private RSA key that is used as a basis for encryption of communication with the device. This plugin only works with Tenable.ot. Please visit...
Siemens LOGO! 8 BM Use of Hard-Coded Cryptographic Key (CVE-2020-25231)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3, LOGO! Soft Comfort All versions V8.3. The encryption of program data for the affected devices uses a static key. An attacker could use this key to extract confidential information from protected program...
Siemens LOGO! Missing Authentication For Critical Function (CVE-2020-7589)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions. The vulnerability could lead to an attacker reading and modifying the device configuration and obtain project files from affected devices. The security vulnerability could be exploited by an unauthenticated...
Siemens LOGO! Web Server Buffer Copy Without Checking Size of Input (CVE-2020-7593)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants V1.81.01 - V1.81.03, LOGO! 8 BM incl. SIPLUS variants V1.82.01, LOGO! 8 BM incl. SIPLUS variants V1.82.02. A buffer overflow vulnerability exists in the Web Server functionality of the device. A remote unauthenticated attacke...
Siemens LOGO! 8 BM Improper Handling of Exceptional Conditions (CVE-2020-25236)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions. The control logic CL the LOGO! 8 executes could be manipulated in a way that could cause the device executing the CL to improperly handle the manipulation and crash. After successful execution of the attack, the...
Siemens LOGO! 8 BM Plaintext Storage of a Password (CVE-2019-10921)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3. Unencrypted storage of passwords in the project could allow an attacker with access to port 10005/tcp to obtain passwords of the device. The security vulnerability could be exploited by an unauthenticated...
Siemens LOGO! 8 BM Use of Hard-Coded Cryptographic Key (CVE-2020-25234)
A vulnerability has been identified in LOGO! 8 BM incl. SIPLUS variants All versions V8.3, LOGO! Soft Comfort All versions V8.3. The LOGO! program files generated and used by the affected components offer the possibility to save user-defined functions UDF in a password protected way. This...