1740 matches found
ABB M2M ETHERNET Improper Authentication (CVE-2018-17926)
The product M2M ETHERNET FW Versions 2.22 and prior, ETH-FW Versions 1.01 and prior is vulnerable in that an attacker can upload a malicious language file by bypassing the user authentication mechanism. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-...
Siemens SICAM A8000 Use of Hard-Coded Credentials (CVE-2021-45033)
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70C All versions V16.20, CP-8000 MASTER MODULE WITH I/O -40/+70C All versions V16.20, CP-8021 MASTER MODULE All versions V16.20, CP-8022 MASTER MODULE WITH GPRS All versions V16.20. An undocumented debug port uses hard-cod...
Siemens SICAM Q100 Improper Input Validation (CVE-2022-43439)
A vulnerability has been identified in POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, POWER METER SICAM Q100 All versions V2.50, SICAM P850 All versions V3.10, SICAM P850 All versions V3.10, SICAM P850 All versions...
Siemens POWER METER SICAM Q100 Stack-Based Buffer Overflow (CVE-2021-44165)
A vulnerability has been identified in POWER METER SICAM Q100 All versions V2.41, POWER METER SICAM Q100 All versions V2.41, POWER METER SICAM Q100 All versions V2.41, POWER METER SICAM Q100 All versions V2.41. The affected firmware contains a buffer overflow vulnerability in the web application...
Siemens SICAM A8000 Improper Access Control (CVE-2021-45034)
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70C All versions V16.20, CP-8000 MASTER MODULE WITH I/O -40/+70C All versions V16.20, CP-8021 MASTER MODULE All versions V16.20, CP-8022 MASTER MODULE WITH GPRS All versions V16.20. The web server of the affected system...
Siemens SICAM A8000 Web Server Module Improper Access Control (CVE-2021-46304)
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70C All versions, CP-8000 MASTER MODULE WITH I/O -40/+70C All versions, CP-8021 MASTER MODULE All versions, CP-8022 MASTER MODULE WITH GPRS All versions. The component allows to activate a web server module which provides...
FANUC Robot Controllers Integer Coercion Error (CVE-2021-32996)
The FANUC R-30iA and R-30iB series controllers are vulnerable to integer coercion errors, which cause the device to crash. A restart is required. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable,...
Siemens SCALANCE W1750D Command Injection (CVE-2018-7082)
A command injection vulnerability is present in Aruba Instant that permits an authenticated administrative user to execute arbitrary commands on the underlying operating system. A malicious administrator could use this ability to install backdoors or change system configuration in a way that woul...
Siemens SCALANCE W1750D Improper Input Validation (CVE-2021-25145)
A remote unauthorized disclosure of information vulnerability was discovered in some Aruba Instant Access Point IAP products in versions: Aruba Instant 6.4.x: 6.4.4.8-4.2.4.18 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.1...
Siemens SCALANCE W1750D Improper Neutralization of Input During Web Page Generation (CVE-2018-7064)
A reflected cross-site scripting XSS vulnerability is present in an unauthenticated Aruba Instant web interface. An attacker could use this vulnerability to trick an IAP administrator into clicking a link which could then take administrative actions on the Instant cluster, or expose the session...
Siemens SCALANCE M875 Insufficiently Protected Credentials (CVE-2018-11449)
A vulnerability has been identified in SCALANCE M875 All versions. An attacker with access to the local file system might obtain passwords for administrative users. Successful exploitation requires read access to files on the local file system. A successful attack could allow an attacker to obtai...
Siemens SCALANCE Improper Input Validation (CVE-2020-26144)
An issue was discovered on Samsung Galaxy S3 i9305 4.4.4 devices. The WEP, WPA, WPA2, and WPA3 implementations accept plaintext A-MSDU frames as long as the first 8 bytes correspond to a valid RFC1042 i.e., LLC/SNAP header for EAPOL. An adversary can abuse this to inject arbitrary network packets...
Siemens SCALANCE Command Injection (CVE-2021-37723)
A remote arbitrary command execution vulnerability was discovered in Aruba Operating System Software versions: Prior to 8.7.1.2, 8.6.0.8, 8.5.0.12, 8.3.0.16. Aruba has released patches for ArubaOS that address this security vulnerability. This plugin only works with Tenable.ot. Please visit...
Siemens SCALANCE W1750D Improper Neutralization of Input During Web Page Generation (CVE-2022-37892)
A vulnerability in the Aruba InstantOS and ArubaOS 10 web management interface could allow an unauthenticated remote attacker to conduct a stored cross-site scripting XSS attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a...
Siemens SCALANCE W1750D Command Injection (CVE-2021-25162)
A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point IAP products in versions: Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and...
Siemens SCALANCE W1750D Classic Buffer Overflow (CVE-2022-37890)
Unauthenticated buffer overflow vulnerabilities exist within the Aruba InstantOS and ArubaOS 10 web management interface. Successful exploitation results in the execution of arbitrary commands on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS...
Siemens SCALANCE W1750D Improper Input Validation (CVE-2021-25155)
A remote arbitrary file modification vulnerability was discovered in some Aruba Instant Access Point IAP products in versions: Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and below...
Siemens Industrial Devices using libcurl Use After Free (CVE-2021-22924)
libcurl keeps previously used connections in a connection pool for subsequenttransfers to reuse, if one of them matches the setup.Due to errors in the logic, the config matching function did not take 'issuercert' into account and it compared the involved paths case insensitively,which could lead ...
Siemens SCALANCE W1750D Command Injection (CVE-2020-24635)
A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point IAP products in versions: Aruba Instant 6.5.x: 6.5.4.17 and below; Aruba Instant 8.3.x: 8.3.0.13 and below; Aruba Instant 8.5.x: 8.5.0.10 and below; Aruba Instant 8.6.x: 8.6.0.5 and below; Aru...
Siemens SCALANCE W1750D Classic Buffer Overflow (CVE-2021-25149)
A remote buffer overflow vulnerability was discovered in some Aruba Instant Access Point IAP products in versions: Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.16 and below; Aruba Instant 8.3.x: 8.3.0.12 and below; Aruba Instant 8.5.x: 8.5.0.6 and below; Aruba Insta...