Lucene search
+L

1740 matches found

Tenable Nessus
Tenable Nessus
added 2023/06/29 12:00 a.m.22 views

Schneider Electric Modicon Missing Authentication for Critical Function (CVE-2020-7540)

A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules see security notification for affected versions, that could cause unauthenticated command executio...

9.8CVSS8.4AI score0.0222EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2023/06/29 12:00 a.m.18 views

Schneider Electric Modicon Premium, Modicon Quantum, Modicon M340, and Modicon BMXNOR0200 Use of Hard-Coded Credentials (CVE-2018-7241)

Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information...

10CVSS8.4AI score0.03768EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2023/06/29 12:00 a.m.19 views

Schneider Electric Modicon Premium, Modicon Quantum, Modicon M340, and Modicon BMXNOR0200 Stack-Based Buffer Overflow (CVE-2018-7240)

A vulnerability exists in Schneider Electric's Modicon Quantum in all versions of the communication modules which could allow arbitrary code execution. An FTP command used to upgrade the firmware of the module can be misused to cause a denial of service, or in extreme cases, to load a malicious...

8.8CVSS8.1AI score0.03262EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2023/06/20 12:00 a.m.17 views

Eaton 9000X Drive Stack-Based Buffer Overflow (CVE-2018-8847)

Eaton 9000X DriveA versions 2.0.29 and prior has a stack-based buffer overflow vulnerability, which may allow remote code execution. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information. %NASLMINLEVEL 80900 C Tenable, Inc...

9.8CVSS7.7AI score0.06838EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2023/06/19 12:00 a.m.25 views

Mitsubishi Electric MELSEC Series CPU Module Buffer Copy Without Checking Size of Input (CVE-2023-1424)

Buffer Copy without Checking Size of Input 'Classic Buffer Overflow' vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU modules allows a remote unauthenticated attacker to cause a denial of service DoS condition or execute malicious code on a target product by sending special...

10CVSS8AI score0.0344EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2023/06/12 12:00 a.m.16 views

Mitsubishi Electric MELSEC-F Series Improper Initialization (CVE-2021-20613)

Improper initialization vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.16 and prior, FX3U-ENET-L Firmware version 1.16 and prior and FX3U-ENET-P502 Firmware version 1.16 and prior allows a remote unauthenticated attacker to cause a denial-of-service DoS condition in communication...

7.8CVSS7.3AI score0.03595EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2023/06/05 12:00 a.m.24 views

ABB Platform Engineering Tools Insertion of Sensitive Information into Log File (CVE-2022-0010)

Insertion of Sensitive Information into Log File vulnerability in ABB QCS 800xA, ABB QCS AC450, ABB Platform Engineering Tools. An attacker, who already has local access to the QCS nodes, could successfully obtain the password for a system user account. Using this information, the attacker could...

7.8CVSS5.8AI score0.00227EPSS
SaveExploits0References2
Tenable Nessus
Tenable Nessus
added 2023/06/05 12:00 a.m.15 views

Schweitzer Engineering Laboratories RTAC Cross-site Scripting (CVE-2023-31154)

An Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller SEL RTAC Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL...

5.4CVSS5.8AI score0.00439EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/06/05 12:00 a.m.17 views

Schweitzer Engineering Laboratories RTAC Cross-site Scripting (CVE-2023-31158)

An Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller SEL RTAC Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL...

5.4CVSS5.8AI score0.00439EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/06/05 12:00 a.m.21 views

Schweitzer Engineering Laboratories RTAC Improper Input Validation (CVE-2023-31149)

An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller SEL RTAC Web Interface could allow a remote authenticated attacker to execute arbitrary code. See SEL Service Bulletin dated 2022-11-15 for more details. This plugin only works wi...

9.1CVSS8.1AI score0.01086EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/06/05 12:00 a.m.30 views

Schweitzer Engineering Laboratories RTAC Path Traversal (CVE-2023-31166)

An Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller SEL RTAC Web Interface could allow a remote authenticated attacker to create folders in arbitrary paths of the file system. See...

4.3CVSS5.8AI score0.00588EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/06/05 12:00 a.m.16 views

Schweitzer Engineering Laboratories RTAC Cross-site Scripting (CVE-2023-31156)

An Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller SEL RTAC Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL...

5.4CVSS5.8AI score0.00439EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/06/05 12:00 a.m.16 views

Schweitzer Engineering Laboratories RTAC Cross-site Scripting (CVE-2023-31164)

An Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller SEL RTAC Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL...

5.4CVSS5.8AI score0.00439EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/06/05 12:00 a.m.17 views

Schweitzer Engineering Laboratories RTAC Improper Input Validation (CVE-2023-31161)

An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller SEL RTAC Web Interface could allow an authenticated remote attacker to use internal resources, allowing a variety of potential effects. See SEL Service Bulletin dated 2022-11-15 f...

8.8CVSS8.1AI score0.00543EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/06/05 12:00 a.m.15 views

Schweitzer Engineering Laboratories RTAC Cross-site Scripting (CVE-2023-31165)

An Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller SEL RTAC Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL...

5.4CVSS5.8AI score0.00439EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/06/05 12:00 a.m.21 views

Schweitzer Engineering Laboratories RTAC Cross-site Scripting (CVE-2023-31155)

An Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller SEL RTAC Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL...

5.4CVSS5.8AI score0.00439EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/06/05 12:00 a.m.23 views

Schweitzer Engineering Laboratories RTAC Insecure Storage of Sensitive Information (CVE-2023-31150)

A Storing Passwords in a Recoverable Format vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller SEL RTAC database system could allow an authenticated attacker to retrieve passwords. See SEL Service Bulletin dated 2022-11-15 for more details. This plugin only...

8CVSS6.4AI score0.00473EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/06/05 12:00 a.m.20 views

Schweitzer Engineering Laboratories RTAC Cross-site Scripting (CVE-2023-31163)

An Improper Neutralization of Input During Web Page Generation 'Cross-site Scripting' vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller SEL RTAC Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL...

5.4CVSS5.8AI score0.00439EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
added 2023/05/24 12:00 a.m.27 views

Rockwell ArmorStart Improper Input Validation (CVE-2023-29027)

A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user with admin privileges and network access to view user data and modify the web interface. Additionally, a malicious user could potentially cause...

5.9CVSS5.8AI score0.0062EPSS
SaveExploits0References4
Tenable Nessus
Tenable Nessus
added 2023/05/24 12:00 a.m.23 views

Rockwell ArmorStart Improper Input Validation (CVE-2023-29023)

A cross site scripting vulnerability was discovered in Rockwell Automation's ArmorStart ST product that could potentially allow a malicious user to view and modify sensitive data or make the web page unavailable. User interaction, such as a phishing attack, is required for successful exploitation...

7CVSS5.8AI score0.0049EPSS
SaveExploits0References4
Rows per page
Query Builder